Search criteria Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

1 vulnerability by airveda

CVE-2024-7408 (GCVE-0-2024-7408)

Vulnerability from cvelistv5 – Published: 2024-08-09 10:40 – Updated: 2024-08-09 15:14
VLAI
Title
Information Disclosure Vulnerability in Airveda Air Quality Monitor
Summary
This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP. Successful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Airveda Air Quality Monitor PM2.5 PM10 Affected: 0 , < 7.4.4.39 (custom)
Create a notification for this product.
Credits
This vulnerability is reported by Anand Agrawal and Dr. Rajib Ranjan Maiti from BITS-Pilani, Hyderabad Campus
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-7408",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-09T15:14:02.118389Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-09T15:14:15.681Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Air Quality Monitor PM2.5 PM10",
          "vendor": "Airveda",
          "versions": [
            {
              "lessThan": "7.4.4.39",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "This vulnerability is reported by Anand Agrawal and Dr. Rajib Ranjan Maiti from BITS-Pilani, Hyderabad Campus"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system.\u003cbr\u003e\u003cbr\u003e"
            }
          ],
          "value": "This vulnerability exists in Airveda Air Quality Monitor PM2.5 PM10 due to transmission of sensitive information in plain text during AP pairing mode. An attacker in close proximity could exploit this vulnerability by capturing Wi-Fi traffic of Airveda-AP.\n\nSuccessful exploitation of this vulnerability could allow the attacker to cause Evil Twin attack on the targeted system."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-65",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-65 Sniff Application Code"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-09T10:40:54.953Z",
        "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "shortName": "CERT-In"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2024-0233"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Upgrade to patched version 7.4.4.39\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to patched version 7.4.4.39"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure Vulnerability in Airveda Air Quality Monitor",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
    "assignerShortName": "CERT-In",
    "cveId": "CVE-2024-7408",
    "datePublished": "2024-08-09T10:40:54.953Z",
    "dateReserved": "2024-08-02T10:47:10.549Z",
    "dateUpdated": "2024-08-09T15:14:15.681Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}