Search criteria
4 vulnerabilities by componentone
CVE-2012-0227 (GCVE-0-2012-0227)
Vulnerability from cvelistv5 – Published: 2012-10-12 20:00 – Updated: 2024-08-06 18:16
VLAI?
Summary
Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T18:16:19.833Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf"
},
{
"name": "51601",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/51601"
},
{
"name": "flexgrid-activex-bo(72604)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72604"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://dsecrg.com/pages/vul/show.php?id=406"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2012-01-20T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-28T12:57:01",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf"
},
{
"name": "51601",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/51601"
},
{
"name": "flexgrid-activex-bo(72604)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72604"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://dsecrg.com/pages/vul/show.php?id=406"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-0227",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Buffer overflow in the VSFlex7.VSFlexGrid ActiveX control in ComponentOne FlexGrid 7.1, as used in Open Automation Software OPC Systems.NET, allows remote attackers to cause a denial of service and possibly execute arbitrary code via a long archive file name argument to the Archive method."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-012-01A.pdf"
},
{
"name": "51601",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/51601"
},
{
"name": "flexgrid-activex-bo(72604)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/72604"
},
{
"name": "http://dsecrg.com/pages/vul/show.php?id=406",
"refsource": "MISC",
"url": "http://dsecrg.com/pages/vul/show.php?id=406"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-0227",
"datePublished": "2012-10-12T20:00:00",
"dateReserved": "2011-12-21T00:00:00",
"dateUpdated": "2024-08-06T18:16:19.833Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2008-4827 (GCVE-0-2008-4827)
Vulnerability from cvelistv5 – Published: 2009-01-08 19:00 – Updated: 2024-08-07 10:31
VLAI?
Summary
Multiple heap-based buffer overflows in the AddTab method in the (1) Tab and (2) CTab ActiveX controls in c1sizer.ocx and the (3) TabOne ActiveX control in sizerone.ocx in ComponentOne SizerOne 8.0.20081.140, as used in ComponentOne Studio for ActiveX 2008, TSC2 Help Desk 4.1.8, SAP GUI 6.40 Patch 29 and 7.10, and possibly other products, allow remote attackers to execute arbitrary code by adding many tabs, or adding tabs with long tab captions.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T10:31:27.857Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20090107 Secunia Research: TSC2 Help Desk CTab ActiveX Control Buffer Overflow",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://www.securityfocus.com/archive/1/499830/100/0/threaded"
},
{
"name": "ADV-2009-0037",
"tags": [
"vdb-entry",
"x_refsource_VUPEN",
"x_transferred"
],
"url": "http://www.vupen.com/english/advisories/2009/0037"
},
{
"name": "ADV-2009-0036",
"tags": [
"vdb-entry",
"x_refsource_VUPEN",
"x_transferred"
],
"url": "http://www.vupen.com/english/advisories/2009/0036"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://secunia.com/secunia_research/2008-54/"
},
{
"name": "sapgui-tabone-bo(47770)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47770"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://secunia.com/secunia_research/2008-53/"
},
{
"name": "33148",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/33148"
},
{
"name": "sizerone-tab-bo(47771)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47771"
},
{
"name": "32648",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/32648"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://secunia.com/secunia_research/2008-52/"
},
{
"name": "1021529",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK",
"x_transferred"
],
"url": "http://securitytracker.com/id?1021529"
},
{
"name": "32609",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/32609"
},
{
"name": "4879",
"tags": [
"third-party-advisory",
"x_refsource_SREASON",
"x_transferred"
],
"url": "http://securityreason.com/securityalert/4879"
},
{
"name": "32672",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA",
"x_transferred"
],
"url": "http://secunia.com/advisories/32672"
},
{
"name": "tsc2-ctab-bo(47769)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47769"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2009-01-07T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple heap-based buffer overflows in the AddTab method in the (1) Tab and (2) CTab ActiveX controls in c1sizer.ocx and the (3) TabOne ActiveX control in sizerone.ocx in ComponentOne SizerOne 8.0.20081.140, as used in ComponentOne Studio for ActiveX 2008, TSC2 Help Desk 4.1.8, SAP GUI 6.40 Patch 29 and 7.10, and possibly other products, allow remote attackers to execute arbitrary code by adding many tabs, or adding tabs with long tab captions."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-10-11T19:57:01",
"orgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
"shortName": "flexera"
},
"references": [
{
"name": "20090107 Secunia Research: TSC2 Help Desk CTab ActiveX Control Buffer Overflow",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://www.securityfocus.com/archive/1/499830/100/0/threaded"
},
{
"name": "ADV-2009-0037",
"tags": [
"vdb-entry",
"x_refsource_VUPEN"
],
"url": "http://www.vupen.com/english/advisories/2009/0037"
},
{
"name": "ADV-2009-0036",
"tags": [
"vdb-entry",
"x_refsource_VUPEN"
],
"url": "http://www.vupen.com/english/advisories/2009/0036"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://secunia.com/secunia_research/2008-54/"
},
{
"name": "sapgui-tabone-bo(47770)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47770"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://secunia.com/secunia_research/2008-53/"
},
{
"name": "33148",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/33148"
},
{
"name": "sizerone-tab-bo(47771)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47771"
},
{
"name": "32648",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/32648"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://secunia.com/secunia_research/2008-52/"
},
{
"name": "1021529",
"tags": [
"vdb-entry",
"x_refsource_SECTRACK"
],
"url": "http://securitytracker.com/id?1021529"
},
{
"name": "32609",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/32609"
},
{
"name": "4879",
"tags": [
"third-party-advisory",
"x_refsource_SREASON"
],
"url": "http://securityreason.com/securityalert/4879"
},
{
"name": "32672",
"tags": [
"third-party-advisory",
"x_refsource_SECUNIA"
],
"url": "http://secunia.com/advisories/32672"
},
{
"name": "tsc2-ctab-bo(47769)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47769"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT-CNA@flexerasoftware.com",
"ID": "CVE-2008-4827",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple heap-based buffer overflows in the AddTab method in the (1) Tab and (2) CTab ActiveX controls in c1sizer.ocx and the (3) TabOne ActiveX control in sizerone.ocx in ComponentOne SizerOne 8.0.20081.140, as used in ComponentOne Studio for ActiveX 2008, TSC2 Help Desk 4.1.8, SAP GUI 6.40 Patch 29 and 7.10, and possibly other products, allow remote attackers to execute arbitrary code by adding many tabs, or adding tabs with long tab captions."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20090107 Secunia Research: TSC2 Help Desk CTab ActiveX Control Buffer Overflow",
"refsource": "BUGTRAQ",
"url": "http://www.securityfocus.com/archive/1/499830/100/0/threaded"
},
{
"name": "ADV-2009-0037",
"refsource": "VUPEN",
"url": "http://www.vupen.com/english/advisories/2009/0037"
},
{
"name": "ADV-2009-0036",
"refsource": "VUPEN",
"url": "http://www.vupen.com/english/advisories/2009/0036"
},
{
"name": "http://secunia.com/secunia_research/2008-54/",
"refsource": "MISC",
"url": "http://secunia.com/secunia_research/2008-54/"
},
{
"name": "sapgui-tabone-bo(47770)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47770"
},
{
"name": "http://secunia.com/secunia_research/2008-53/",
"refsource": "MISC",
"url": "http://secunia.com/secunia_research/2008-53/"
},
{
"name": "33148",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/33148"
},
{
"name": "sizerone-tab-bo(47771)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47771"
},
{
"name": "32648",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/32648"
},
{
"name": "http://secunia.com/secunia_research/2008-52/",
"refsource": "MISC",
"url": "http://secunia.com/secunia_research/2008-52/"
},
{
"name": "1021529",
"refsource": "SECTRACK",
"url": "http://securitytracker.com/id?1021529"
},
{
"name": "32609",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/32609"
},
{
"name": "4879",
"refsource": "SREASON",
"url": "http://securityreason.com/securityalert/4879"
},
{
"name": "32672",
"refsource": "SECUNIA",
"url": "http://secunia.com/advisories/32672"
},
{
"name": "tsc2-ctab-bo(47769)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/47769"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "44d08088-2bea-4760-83a6-1e9be26b15ab",
"assignerShortName": "flexera",
"cveId": "CVE-2008-4827",
"datePublished": "2009-01-08T19:00:00",
"dateReserved": "2008-10-31T00:00:00",
"dateUpdated": "2024-08-07T10:31:27.857Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2008-4132 (GCVE-0-2008-4132)
Vulnerability from cvelistv5 – Published: 2008-09-19 17:04 – Updated: 2024-08-07 10:08
VLAI?
Summary
Stack-based buffer overflow in the VSFlexGrid.VSFlexGridL ActiveX control in ComponentOne VSFlexGrid 7.0.1.151 and 8.0.20072.239 allows remote attackers to execute arbitrary code via a long first argument to the Archive method. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T10:08:34.048Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "componentone-vsflexgrid-bo(45184)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/45184"
},
{
"name": "31200",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/31200"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2008-09-16T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Stack-based buffer overflow in the VSFlexGrid.VSFlexGridL ActiveX control in ComponentOne VSFlexGrid 7.0.1.151 and 8.0.20072.239 allows remote attackers to execute arbitrary code via a long first argument to the Archive method. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-08-07T12:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "componentone-vsflexgrid-bo(45184)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/45184"
},
{
"name": "31200",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/31200"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2008-4132",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Stack-based buffer overflow in the VSFlexGrid.VSFlexGridL ActiveX control in ComponentOne VSFlexGrid 7.0.1.151 and 8.0.20072.239 allows remote attackers to execute arbitrary code via a long first argument to the Archive method. NOTE: the provenance of this information is unknown; the details are obtained solely from third party information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "componentone-vsflexgrid-bo(45184)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/45184"
},
{
"name": "31200",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/31200"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2008-4132",
"datePublished": "2008-09-19T17:04:00",
"dateReserved": "2008-09-19T00:00:00",
"dateUpdated": "2024-08-07T10:08:34.048Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2007-6028 (GCVE-0-2007-6028)
Vulnerability from cvelistv5 – Published: 2007-11-20 01:00 – Updated: 2024-08-07 15:54
VLAI?
Summary
Multiple stack-based buffer overflows in the VSFlexGrid.VSFlexGridL ActiveX control in ComponentOne FlexGrid 7.1 Light allow remote attackers to cause a denial of service and possibly execute arbitrary code via a long string in the (1) Text, (2) EditSelText, (3) EditText, and (4) CellFontName property values.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-07T15:54:26.293Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "componentone-flexgrid-bo(38507)",
"tags": [
"vdb-entry",
"x_refsource_XF",
"x_transferred"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/38507"
},
{
"name": "26467",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/26467"
},
{
"name": "20071115 ComponentOne FlexGrid 7.1 Light Multiple Stack Overflows",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://marc.info/?l=full-disclosure\u0026m=119517573408574\u0026w=2"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2007-11-15T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple stack-based buffer overflows in the VSFlexGrid.VSFlexGridL ActiveX control in ComponentOne FlexGrid 7.1 Light allow remote attackers to cause a denial of service and possibly execute arbitrary code via a long string in the (1) Text, (2) EditSelText, (3) EditText, and (4) CellFontName property values."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-07-28T12:57:01",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "componentone-flexgrid-bo(38507)",
"tags": [
"vdb-entry",
"x_refsource_XF"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/38507"
},
{
"name": "26467",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/26467"
},
{
"name": "20071115 ComponentOne FlexGrid 7.1 Light Multiple Stack Overflows",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://marc.info/?l=full-disclosure\u0026m=119517573408574\u0026w=2"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2007-6028",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple stack-based buffer overflows in the VSFlexGrid.VSFlexGridL ActiveX control in ComponentOne FlexGrid 7.1 Light allow remote attackers to cause a denial of service and possibly execute arbitrary code via a long string in the (1) Text, (2) EditSelText, (3) EditText, and (4) CellFontName property values."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "componentone-flexgrid-bo(38507)",
"refsource": "XF",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/38507"
},
{
"name": "26467",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/26467"
},
{
"name": "20071115 ComponentOne FlexGrid 7.1 Light Multiple Stack Overflows",
"refsource": "FULLDISC",
"url": "http://marc.info/?l=full-disclosure\u0026m=119517573408574\u0026w=2"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2007-6028",
"datePublished": "2007-11-20T01:00:00",
"dateReserved": "2007-11-19T00:00:00",
"dateUpdated": "2024-08-07T15:54:26.293Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}