    CVE-2013-4735 (GCVE-0-2013-4735)

    Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
    VLAI
    Summary
    The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:27.034Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4735",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4735",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:57:08.864Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-4734 (GCVE-0-2013-4734)

    Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:10
    VLAI
    Summary
    dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-330 - Use of Insufficiently Random Values
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:27.167Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 7.3,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-4734",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:10:09.535162Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-330",
                    "description": "CWE-330 Use of Insufficiently Random Values",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:10:12.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4734",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4734",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:10:12.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-4733 (GCVE-0-2013-4733)

    Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:11
    VLAI
    Summary
    The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-532 - Insertion of Sensitive Information into Log File
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:26.967Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-4733",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:11:06.221944Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-532",
                    "description": "CWE-532 Insertion of Sensitive Information into Log File",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:11:17.241Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4733",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4733",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:11:17.241Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-4732 (GCVE-0-2013-4732)

    Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54 Disputed
    VLAI
    Summary
    The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:27.001Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4732",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "MISC",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "MISC",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "MISC",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "MISC",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4732",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:54:12.663Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-0137 (GCVE-0-2013-0137)

    Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
    VLAI
    Summary
    The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-06-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T14:18:09.572Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-06-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-29T17:01:40.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-0137",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
                  "refsource": "MISC",
                  "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-0137",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2012-12-06T00:00:00.000Z",
        "dateUpdated": "2024-08-06T14:18:09.572Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-4735 (GCVE-0-2013-4735)

    Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
    VLAI
    Summary
    The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:27.034Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4735",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4735",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2024-09-17T02:57:08.864Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-4732 (GCVE-0-2013-4732)

    Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54 Disputed
    VLAI
    Summary
    The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:27.001Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4732",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "MISC",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "MISC",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "MISC",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "MISC",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4732",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2024-09-16T17:54:12.663Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2013-4733 (GCVE-0-2013-4733)

    Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:11
    VLAI
    Summary
    The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-532 - Insertion of Sensitive Information into Log File
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:26.967Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-4733",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:11:06.221944Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-532",
                    "description": "CWE-532 Insertion of Sensitive Information into Log File",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:11:17.241Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4733",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4733",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:11:17.241Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-4734 (GCVE-0-2013-4734)

    Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:10
    VLAI
    Summary
    dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • n/a
    • CWE-330 - Use of Insufficiently Random Values
    Assigner
    References
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T16:52:27.167Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 7.3,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "LOW",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2013-4734",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-02T19:10:09.535162Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-330",
                    "description": "CWE-330 Use of Insufficiently Random Values",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-02T19:10:12.857Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2013-06-29T21:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2013-4734",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2013-4734",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2013-06-29T00:00:00.000Z",
        "dateUpdated": "2026-06-02T19:10:12.857Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2013-0137 (GCVE-0-2013-0137)

    Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
    VLAI
    Summary
    The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
    Severity
    No CVSS data available.
    CWE
    • n/a
    Assigner
    Date Public
    2013-06-24 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-06T14:18:09.572Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
              },
              {
                "name": "VU#662676",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_CERT-VN",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/662676"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_CONFIRM",
                  "x_transferred"
                ],
                "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2013-06-24T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-01-29T17:01:40.000Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "tags": [
                "third-party-advisory",
                "x_refsource_CERT-VN"
              ],
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_CONFIRM"
              ],
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cert@cert.org",
              "ID": "CVE-2013-0137",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
                },
                {
                  "name": "VU#662676",
                  "refsource": "CERT-VN",
                  "url": "http://www.kb.cert.org/vuls/id/662676"
                },
                {
                  "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
                  "refsource": "CONFIRM",
                  "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
                },
                {
                  "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
                  "refsource": "CONFIRM",
                  "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
                },
                {
                  "name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
                  "refsource": "MISC",
                  "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2013-0137",
        "datePublished": "2013-06-29T21:00:00.000Z",
        "dateReserved": "2012-12-06T00:00:00.000Z",
        "dateUpdated": "2024-08-06T14:18:09.572Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }