CVE-2013-4735 (GCVE-0-2013-4735)
Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
VLAI
EPSS
VEX
Summary
The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.034Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4735",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4735",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:57:08.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4734 (GCVE-0-2013-4734)
Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:10
VLAI
EPSS
VEX
Summary
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
Severity
7.3 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.167Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2013-4734",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:10:09.535162Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330 Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T19:10:12.857Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4734",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4734",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2026-06-02T19:10:12.857Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2013-4733 (GCVE-0-2013-4733)
Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:11
VLAI
EPSS
VEX
Summary
The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:26.967Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2013-4733",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:11:06.221944Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T19:11:17.241Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4733",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4733",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2026-06-02T19:11:17.241Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2013-4732 (GCVE-0-2013-4732)
Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54 Disputed
VLAI
EPSS
VEX
Summary
The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_MISC |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_MISC |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_MISC |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.001Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
}
],
"tags": [
"disputed"
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4732",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "MISC",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "MISC",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "MISC",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "MISC",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4732",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:54:12.663Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-0137 (GCVE-0-2013-0137)
Vulnerability from nvd – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
VLAI
EPSS
VEX
Summary
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
| https://securityledger.com/2020/01/seven-years-la… | x_refsource_MISC |
Date Public
2013-06-24 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:18:09.572Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-06-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-29T17:01:40.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2013-0137",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
"refsource": "MISC",
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2013-0137",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2012-12-06T00:00:00.000Z",
"dateUpdated": "2024-08-06T14:18:09.572Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4735 (GCVE-0-2013-4735)
Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
VLAI
EPSS
VEX
Summary
The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.034Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4735",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4735",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2024-09-17T02:57:08.864Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4732 (GCVE-0-2013-4732)
Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54 Disputed
VLAI
EPSS
VEX
Summary
The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_MISC |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_MISC |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_MISC |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.001Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
}
],
"tags": [
"disputed"
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4732",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "MISC",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "MISC",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "MISC",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "MISC",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4732",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T17:54:12.663Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-4733 (GCVE-0-2013-4733)
Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:11
VLAI
EPSS
VEX
Summary
The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:26.967Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2013-4733",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:11:06.221944Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532 Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T19:11:17.241Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4733",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4733",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2026-06-02T19:11:17.241Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2013-4734 (GCVE-0-2013-4734)
Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2026-06-02 19:10
VLAI
EPSS
VEX
Summary
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
Severity
7.3 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-330 - Use of Insufficiently Random Values
Assigner
References
5 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T16:52:27.167Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2013-4734",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T19:10:09.535162Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-330",
"description": "CWE-330 Use of Insufficiently Random Values",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T19:10:12.857Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2013-06-29T21:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2013-4734",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2013-4734",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2013-06-29T00:00:00.000Z",
"dateUpdated": "2026-06-02T19:10:12.857Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2013-0137 (GCVE-0-2013-0137)
Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
VLAI
EPSS
VEX
Summary
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
6 references
| URL | Tags |
|---|---|
| http://www.kb.cert.org/vuls/id/AAMN-98MUK2 | x_refsource_CONFIRM |
| http://www.kb.cert.org/vuls/id/662676 | third-party-advisoryx_refsource_CERT-VN |
| http://www.kb.cert.org/vuls/id/AAMN-98MU7H | x_refsource_CONFIRM |
| http://www.monroe-electronics.com/MONROE_ELECTRON… | x_refsource_CONFIRM |
| http://www.digitalalertsystems.com/pdf/130604-Mon… | x_refsource_CONFIRM |
| https://securityledger.com/2020/01/seven-years-la… | x_refsource_MISC |
Date Public
2013-06-24 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T14:18:09.572Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2013-06-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-29T17:01:40.000Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2013-0137",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
},
{
"name": "VU#662676",
"refsource": "CERT-VN",
"url": "http://www.kb.cert.org/vuls/id/662676"
},
{
"name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
"refsource": "CONFIRM",
"url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
},
{
"name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
},
{
"name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
"refsource": "CONFIRM",
"url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
},
{
"name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
"refsource": "MISC",
"url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2013-0137",
"datePublished": "2013-06-29T21:00:00.000Z",
"dateReserved": "2012-12-06T00:00:00.000Z",
"dateUpdated": "2024-08-06T14:18:09.572Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}