Search

Find a vulnerability

Search criteria ⓘ Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.

    9 vulnerabilities by lutron

    VAR-201806-0915

    Vulnerability from variot - Updated: 2024-06-11 22:51

    Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine. Stanza Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lutron Electronics radioRA2 and so on are a set of lighting control systems of Lutron Electronics (Lutron Electronics) in the United States. A trust management issue vulnerability exists in Lutron radioRA2, stanza, and HomeworkQS due to the user's inability to disable the default hard-coded credentials in products using this protocol. An attacker could exploit this vulnerability to take control of the device through a TELNET session

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201806-0915",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "radiora 2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "stanza",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "homeworks qs",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "homeworks qs",
            "scope": null,
            "trust": 0.8,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "radiora 2",
            "scope": null,
            "trust": 0.8,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "stanza",
            "scope": null,
            "trust": 0.8,
            "vendor": "lutron",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:radiora_2:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:homeworks_qs:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "cve": "CVE-2018-11682",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-11682",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-121566",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-11682",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-11682",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201806-001",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-121566",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-11682",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine. Stanza Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lutron Electronics radioRA2 and so on are a set of lighting control systems of Lutron Electronics (Lutron Electronics) in the United States. A trust management issue vulnerability exists in Lutron radioRA2, stanza, and HomeworkQS due to the user\u0027s inability to disable the default hard-coded credentials in products using this protocol. An attacker could exploit this vulnerability to take control of the device through a TELNET session",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11682"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-11682",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001",
            "trust": 0.7
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-97787",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11682",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "id": "VAR-201806-0915",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-06-11T22:51:41.627000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "http://www.lutron.com/en-us/pages/default.aspx"
          },
          {
            "title": "Exploits",
            "trust": 0.1,
            "url": "https://github.com/sadfud/exploits "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "http://sadfud.me/explotos/cve-2018-11629"
          },
          {
            "trust": 2.6,
            "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
          },
          {
            "trust": 1.8,
            "url": "http://www.lutron.com/technicaldocumentlibrary/040249.pdf"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11682"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11682"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/798.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/sadfud/exploits"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "date": "2018-06-02T13:29:00.323000",
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-11682"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "date": "2019-07-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          },
          {
            "date": "2024-06-10T18:15:18.183000",
            "db": "NVD",
            "id": "CVE-2018-11682"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Stanza Vulnerabilities related to the use of hard-coded credentials",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201806-0914

    Vulnerability from variot - Updated: 2024-06-05 23:25

    Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine. RadioRA 2 Lutron integration Products that use the protocol are vulnerable to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lutron Electronics radioRA2 and so on are a set of lighting control systems of Lutron Electronics (Lutron Electronics) in the United States. A trust management issue vulnerability exists in Lutron radioRA2, stanza, and HomeworkQS due to the user's inability to disable the default hard-coded credentials in products using this protocol. An attacker could exploit this vulnerability to take control of the device through a TELNET session

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201806-0914",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "radiora 2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "stanza",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "homeworks qs",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "homeworks qs",
            "scope": null,
            "trust": 0.8,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "radiora 2",
            "scope": null,
            "trust": 0.8,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "stanza",
            "scope": null,
            "trust": 0.8,
            "vendor": "lutron",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:radiora_2:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:homeworks_qs:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "cve": "CVE-2018-11681",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-11681",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 0.9,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-121565",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-11681",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-11681",
                "trust": 1.8,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201806-002",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-121565",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-11681",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine. RadioRA 2 Lutron integration Products that use the protocol are vulnerable to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lutron Electronics radioRA2 and so on are a set of lighting control systems of Lutron Electronics (Lutron Electronics) in the United States. A trust management issue vulnerability exists in Lutron radioRA2, stanza, and HomeworkQS due to the user\u0027s inability to disable the default hard-coded credentials in products using this protocol. An attacker could exploit this vulnerability to take control of the device through a TELNET session",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11681"
          }
        ],
        "trust": 1.8
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-11681",
            "trust": 2.6
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002",
            "trust": 0.7
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-97786",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11681",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "id": "VAR-201806-0914",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2024-06-05T23:25:59.167000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "http://www.lutron.com/en-us/pages/default.aspx"
          },
          {
            "title": "Exploits",
            "trust": 0.1,
            "url": "https://github.com/sadfud/exploits "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.6,
            "url": "http://sadfud.me/explotos/cve-2018-11629"
          },
          {
            "trust": 2.6,
            "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
          },
          {
            "trust": 1.8,
            "url": "http://www.lutron.com/technicaldocumentlibrary/040249.pdf"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11681"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11681"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/798.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/sadfud/exploits"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "date": "2018-06-02T13:29:00.277000",
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-11681"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "date": "2019-07-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          },
          {
            "date": "2024-06-04T19:16:56.400000",
            "db": "NVD",
            "id": "CVE-2018-11681"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "RadioRA 2 Lutron integration Vulnerabilities related to the use of hard-coded credentials in products that use protocols",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201806-0950

    Vulnerability from variot - Updated: 2024-05-17 22:47

    Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine. HomeWorks QS Lutron integration Products that use the protocol are vulnerable to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lutron Electronics radioRA2 and so on are a set of lighting control systems of Lutron Electronics of the United States. There is a trust management vulnerability in Lutron radioRA2, stanza, and HomeworkQS, which originates from the program with default credentials that cannot be removed (user: lutron, password: integration). An attacker could use this vulnerability to control IoT devices as a superuser

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201806-0950",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "homeworks qs",
            "scope": null,
            "trust": 2.4,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "radiora 2",
            "scope": null,
            "trust": 2.4,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "stanza",
            "scope": null,
            "trust": 2.4,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "radiora 2",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "stanza",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          },
          {
            "model": "homeworks qs",
            "scope": "eq",
            "trust": 1.6,
            "vendor": "lutron",
            "version": null
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:radiora_2:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              },
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:homeworks_qs:-:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "cve": "CVE-2018-11629",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "Complete",
                "baseScore": 10.0,
                "confidentialityImpact": "Complete",
                "exploitabilityScore": null,
                "id": "CVE-2018-11629",
                "impactScore": null,
                "integrityImpact": "Complete",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "High",
                "trust": 2.5,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "HIGH",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-121507",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-121565",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "exploitabilityScore": 10.0,
                "id": "VHN-121566",
                "impactScore": 10.0,
                "integrityImpact": "COMPLETE",
                "severity": "HIGH",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:C/I:C/A:C",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "High",
                "baseScore": 9.8,
                "baseSeverity": "Critical",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-11629",
                "impactScore": null,
                "integrityImpact": "High",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 2.4,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              },
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 5.9,
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-11629",
                "trust": 3.4,
                "value": "CRITICAL"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201806-003",
                "trust": 0.6,
                "value": "CRITICAL"
              },
              {
                "author": "VULHUB",
                "id": "VHN-121507",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-121565",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULHUB",
                "id": "VHN-121566",
                "trust": 0.1,
                "value": "HIGH"
              },
              {
                "author": "VULMON",
                "id": "CVE-2018-11629",
                "trust": 0.1,
                "value": "HIGH"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Default and unremovable support credentials (user:lutron password:integration) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the HomeWorks QS Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine. HomeWorks QS Lutron integration Products that use the protocol are vulnerable to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lutron Electronics radioRA2 and so on are a set of lighting control systems of Lutron Electronics of the United States. \nThere is a trust management vulnerability in Lutron radioRA2, stanza, and HomeworkQS, which originates from the program with default credentials that cannot be removed (user: lutron, password: integration). An attacker could use this vulnerability to control IoT devices as a superuser",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11629"
          }
        ],
        "trust": 3.96
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-11629",
            "trust": 4.4
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142",
            "trust": 0.8
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003",
            "trust": 0.7
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-97783",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-121507",
            "trust": 0.1
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-002",
            "trust": 0.1
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-97786",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565",
            "trust": 0.1
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-001",
            "trust": 0.1
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-97787",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566",
            "trust": 0.1
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11629",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "id": "VAR-201806-0950",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          }
        ],
        "trust": 0.03
      },
      "last_update_date": "2024-05-17T22:47:44.239000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 2.4,
            "url": "http://www.lutron.com/en-us/pages/default.aspx"
          },
          {
            "title": "Exploits",
            "trust": 0.1,
            "url": "https://github.com/sadfud/exploits "
          }
        ],
        "sources": [
          {
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-798",
            "trust": 3.7
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 4.4,
            "url": "http://sadfud.me/explotos/cve-2018-11629"
          },
          {
            "trust": 4.4,
            "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
          },
          {
            "trust": 2.0,
            "url": "http://www.lutron.com/technicaldocumentlibrary/040249.pdf"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11682"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11682"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11681"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11681"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11629"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11629"
          },
          {
            "trust": 0.1,
            "url": "https://cwe.mitre.org/data/definitions/798.html"
          },
          {
            "trust": 0.1,
            "url": "https://nvd.nist.gov"
          },
          {
            "trust": 0.1,
            "url": "https://github.com/sadfud/exploits"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "date": "2018-06-02T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "date": "2018-06-02T13:29:00.230000",
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121507"
          },
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121565"
          },
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULHUB",
            "id": "VHN-121566"
          },
          {
            "date": "2019-06-27T00:00:00",
            "db": "VULMON",
            "id": "CVE-2018-11629"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006142"
          },
          {
            "date": "2018-08-08T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-006141"
          },
          {
            "date": "2019-07-05T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          },
          {
            "date": "2024-05-17T01:22:37.407000",
            "db": "NVD",
            "id": "CVE-2018-11629"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Stanza Vulnerabilities related to the use of hard-coded credentials",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-006143"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "trust management problem",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201806-003"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201802-1266

    Vulnerability from variot - Updated: 2023-12-18 13:48

    An issue was discovered on Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) devices. Remote attackers can obtain potentially sensitive information via a /DbXmlInfo.xml request, as demonstrated by the Latitude/Longitude of the device. Lutron Quantum BACnet Integration is a lighting control system developed by Lutron Electronics in the United States

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201802-1266",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "quantum bacnet integration",
            "scope": "eq",
            "trust": 2.4,
            "vendor": "lutron",
            "version": "3.2.243"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:quantum_bacnet_integration_firmware:3.2.243:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:quantum_bacnet_integration:2.0:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          }
        ]
      },
      "cve": "CVE-2018-7276",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2018-7276",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-137308",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-7276",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-7276",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201802-770",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-137308",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "An issue was discovered on Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) devices. Remote attackers can obtain potentially sensitive information via a /DbXmlInfo.xml request, as demonstrated by the Latitude/Longitude of the device. Lutron Quantum BACnet Integration is a lighting control system developed by Lutron Electronics in the United States",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          }
        ],
        "trust": 1.71
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-7276",
            "trust": 2.5
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770",
            "trust": 0.7
          },
          {
            "db": "VULHUB",
            "id": "VHN-137308",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "id": "VAR-201802-1266",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T13:48:21.136000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "http://www.lutron.com/en-us/pages/default.aspx"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 1.7,
            "url": "http://misteralfa-hack.blogspot.com/2018/02/bacnet-entrando-en-materia.html"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-7276"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-7276"
          },
          {
            "trust": 0.8,
            "url": "http://misteralfa-hack.blogspot.jp/2018/02/bacnet-entrando-en-materia.html"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-02-21T00:00:00",
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "date": "2018-04-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "date": "2018-02-21T01:29:00.263000",
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "date": "2018-02-20T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-03-18T00:00:00",
            "db": "VULHUB",
            "id": "VHN-137308"
          },
          {
            "date": "2018-04-11T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          },
          {
            "date": "2018-03-18T11:08:46.907000",
            "db": "NVD",
            "id": "CVE-2018-7276"
          },
          {
            "date": "2018-03-16T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Lutron Quantum BACnet Integration Information disclosure vulnerability in devices",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-002410"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201802-770"
          }
        ],
        "trust": 0.6
      }
    }

    VAR-201804-1289

    Vulnerability from variot - Updated: 2023-12-18 12:56

    Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn't check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure. Lutron Quantum BACnet Integration is a lighting control system developed by Lutron Electronics in the United States. There is a security vulnerability in Lutron Quantum BACnet Integration version 2.0 using firmware version 3.2.243. The vulnerability stems from the fact that the program does not properly verify the user's request before displaying /deviceIP information. Attackers can exploit this vulnerability to obtain network information

    Show details on source website

    {
      "@context": {
        "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
        "affected_products": {
          "@id": "https://www.variotdbs.pl/ref/affected_products"
        },
        "configurations": {
          "@id": "https://www.variotdbs.pl/ref/configurations"
        },
        "credits": {
          "@id": "https://www.variotdbs.pl/ref/credits"
        },
        "cvss": {
          "@id": "https://www.variotdbs.pl/ref/cvss/"
        },
        "description": {
          "@id": "https://www.variotdbs.pl/ref/description/"
        },
        "exploit_availability": {
          "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
        },
        "external_ids": {
          "@id": "https://www.variotdbs.pl/ref/external_ids/"
        },
        "iot": {
          "@id": "https://www.variotdbs.pl/ref/iot/"
        },
        "iot_taxonomy": {
          "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
        },
        "patch": {
          "@id": "https://www.variotdbs.pl/ref/patch/"
        },
        "problemtype_data": {
          "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
        },
        "references": {
          "@id": "https://www.variotdbs.pl/ref/references/"
        },
        "sources": {
          "@id": "https://www.variotdbs.pl/ref/sources/"
        },
        "sources_release_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
        },
        "sources_update_date": {
          "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
        },
        "threat_type": {
          "@id": "https://www.variotdbs.pl/ref/threat_type/"
        },
        "title": {
          "@id": "https://www.variotdbs.pl/ref/title/"
        },
        "type": {
          "@id": "https://www.variotdbs.pl/ref/type/"
        }
      },
      "@id": "https://www.variotdbs.pl/vuln/VAR-201804-1289",
      "affected_products": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "model": "quantum bacnet integration",
            "scope": "eq",
            "trust": 2.4,
            "vendor": "lutron",
            "version": "3.2.243"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "configurations": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/configurations#",
          "children": {
            "@container": "@list"
          },
          "cpe_match": {
            "@container": "@list"
          },
          "data": {
            "@container": "@list"
          },
          "nodes": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "CVE_data_version": "4.0",
            "nodes": [
              {
                "children": [
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:o:lutron:quantum_bacnet_integration_firmware:3.2.243:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": true
                      }
                    ],
                    "operator": "OR"
                  },
                  {
                    "children": [],
                    "cpe_match": [
                      {
                        "cpe23Uri": "cpe:2.3:h:lutron:quantum_bacnet_integration:2.0:*:*:*:*:*:*:*",
                        "cpe_name": [],
                        "vulnerable": false
                      }
                    ],
                    "operator": "OR"
                  }
                ],
                "cpe_match": [],
                "operator": "AND"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          }
        ]
      },
      "cve": "CVE-2018-8880",
      "cvss": {
        "@context": {
          "cvssV2": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
          },
          "cvssV3": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
          },
          "severity": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/cvss/severity#"
            },
            "@id": "https://www.variotdbs.pl/ref/cvss/severity"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            },
            "@id": "https://www.variotdbs.pl/ref/sources"
          }
        },
        "data": [
          {
            "cvssV2": [
              {
                "acInsufInfo": false,
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "obtainAllPrivilege": false,
                "obtainOtherPrivilege": false,
                "obtainUserPrivilege": false,
                "severity": "MEDIUM",
                "trust": 1.0,
                "userInteractionRequired": false,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "acInsufInfo": null,
                "accessComplexity": "Low",
                "accessVector": "Network",
                "authentication": "None",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 5.0,
                "confidentialityImpact": "Partial",
                "exploitabilityScore": null,
                "id": "CVE-2018-8880",
                "impactScore": null,
                "integrityImpact": "None",
                "obtainAllPrivilege": null,
                "obtainOtherPrivilege": null,
                "obtainUserPrivilege": null,
                "severity": "Medium",
                "trust": 0.8,
                "userInteractionRequired": null,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "author": "VULHUB",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "exploitabilityScore": 10.0,
                "id": "VHN-138912",
                "impactScore": 2.9,
                "integrityImpact": "NONE",
                "severity": "MEDIUM",
                "trust": 0.1,
                "vectorString": "AV:N/AC:L/AU:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            ],
            "cvssV3": [
              {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "author": "NVD",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "exploitabilityScore": 3.9,
                "impactScore": 3.6,
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "trust": 1.0,
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              },
              {
                "attackComplexity": "Low",
                "attackVector": "Network",
                "author": "NVD",
                "availabilityImpact": "None",
                "baseScore": 7.5,
                "baseSeverity": "High",
                "confidentialityImpact": "High",
                "exploitabilityScore": null,
                "id": "CVE-2018-8880",
                "impactScore": null,
                "integrityImpact": "None",
                "privilegesRequired": "None",
                "scope": "Unchanged",
                "trust": 0.8,
                "userInteraction": "None",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.0"
              }
            ],
            "severity": [
              {
                "author": "NVD",
                "id": "CVE-2018-8880",
                "trust": 1.8,
                "value": "HIGH"
              },
              {
                "author": "CNNVD",
                "id": "CNNVD-201804-1341",
                "trust": 0.6,
                "value": "MEDIUM"
              },
              {
                "author": "VULHUB",
                "id": "VHN-138912",
                "trust": 0.1,
                "value": "MEDIUM"
              }
            ]
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "description": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/description#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Lutron Quantum BACnet Integration 2.0 (firmware 3.2.243) doesn\u0027t check for correct user authentication before showing the /deviceIP information, which leads to internal network information disclosure. Lutron Quantum BACnet Integration is a lighting control system developed by Lutron Electronics in the United States. There is a security vulnerability in Lutron Quantum BACnet Integration version 2.0 using firmware version 3.2.243. The vulnerability stems from the fact that the program does not properly verify the user\u0027s request before displaying /deviceIP information. Attackers can exploit this vulnerability to obtain network information",
        "sources": [
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          }
        ],
        "trust": 1.71
      },
      "exploit_availability": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/exploit_availability#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "reference": "https://www.scap.org.cn/vuln/vhn-138912",
            "trust": 0.1,
            "type": "unknown"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          }
        ]
      },
      "external_ids": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "db": "NVD",
            "id": "CVE-2018-8880",
            "trust": 2.5
          },
          {
            "db": "EXPLOIT-DB",
            "id": "44488",
            "trust": 1.7
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486",
            "trust": 0.8
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341",
            "trust": 0.7
          },
          {
            "db": "SEEBUG",
            "id": "SSVID-97794",
            "trust": 0.1
          },
          {
            "db": "VULHUB",
            "id": "VHN-138912",
            "trust": 0.1
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "id": "VAR-201804-1289",
      "iot": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/iot#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": true,
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          }
        ],
        "trust": 0.01
      },
      "last_update_date": "2023-12-18T12:56:59.954000Z",
      "patch": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/patch#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "title": "Top Page",
            "trust": 0.8,
            "url": "http://www.lutron.com/en-us/pages/default.aspx"
          }
        ],
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          }
        ]
      },
      "problemtype_data": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "problemtype": "CWE-200",
            "trust": 1.9
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          }
        ]
      },
      "references": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/references#",
          "data": {
            "@container": "@list"
          },
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": [
          {
            "trust": 2.5,
            "url": "http://sadfud.me/explotos/deviceip.txt"
          },
          {
            "trust": 1.7,
            "url": "https://www.exploit-db.com/exploits/44488/"
          },
          {
            "trust": 0.8,
            "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-8880"
          },
          {
            "trust": 0.8,
            "url": "https://nvd.nist.gov/vuln/detail/cve-2018-8880"
          }
        ],
        "sources": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "sources": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "sources_release_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-04-23T00:00:00",
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "date": "2018-06-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "date": "2018-04-23T18:29:01.037000",
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "date": "2018-04-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "sources_update_date": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
          "data": {
            "@container": "@list"
          }
        },
        "data": [
          {
            "date": "2018-05-25T00:00:00",
            "db": "VULHUB",
            "id": "VHN-138912"
          },
          {
            "date": "2018-06-21T00:00:00",
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          },
          {
            "date": "2018-05-25T15:39:31.343000",
            "db": "NVD",
            "id": "CVE-2018-8880"
          },
          {
            "date": "2018-04-24T00:00:00",
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ]
      },
      "threat_type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "remote",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ],
        "trust": 0.6
      },
      "title": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/title#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "Lutron Quantum BACnet Integration Information Disclosure Vulnerability",
        "sources": [
          {
            "db": "JVNDB",
            "id": "JVNDB-2018-004486"
          }
        ],
        "trust": 0.8
      },
      "type": {
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/type#",
          "sources": {
            "@container": "@list",
            "@context": {
              "@vocab": "https://www.variotdbs.pl/ref/sources#"
            }
          }
        },
        "data": "information disclosure",
        "sources": [
          {
            "db": "CNNVD",
            "id": "CNNVD-201804-1341"
          }
        ],
        "trust": 0.6
      }
    }

    CVE-2018-11681 (GCVE-0-2018-11681)

    Vulnerability from cvelistv5 – Published: 2018-06-02 13:00 – Updated: 2024-08-05 08:17 Disputed
    VLAI
    Summary
    Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-04-23 18:06 UTC
    CWE
    • n/a
    • CWE-798 - Use of Hard-coded Credentials
    Impacted products
    Vendor Product Version
    lutron stanza_firmware Affected: -
        cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    lutron radiora_2_firmware Affected: -
        cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    lutron homeworks_qs_firmware Affected: -
        cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2018-06-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "stanza_firmware",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "radiora_2_firmware",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "homeworks_qs_firmware",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-11681",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-23T18:06:19.899664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-798",
                    "description": "CWE-798 Use of Hard-coded Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:11:56.366Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:17:08.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://sadfud.me/explotos/CVE-2018-11629"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-06-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-27T17:40:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://sadfud.me/explotos/CVE-2018-11629"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11681",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://sadfud.me/explotos/CVE-2018-11629",
                  "refsource": "MISC",
                  "url": "http://sadfud.me/explotos/CVE-2018-11629"
                },
                {
                  "name": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/",
                  "refsource": "MISC",
                  "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
                },
                {
                  "name": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf",
                  "refsource": "MISC",
                  "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11681",
        "datePublished": "2018-06-02T13:00:00.000Z",
        "dateReserved": "2018-06-02T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:17:08.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11682 (GCVE-0-2018-11682)

    Vulnerability from cvelistv5 – Published: 2018-06-02 13:00 – Updated: 2024-08-05 08:17 Disputed
    VLAI
    Summary
    Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-10 17:04 UTC
    CWE
    • n/a
    • CWE-798 - Use of Hard-coded Credentials
    Impacted products
    Vendor Product Version
    lutron stanza Affected: 0
        cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2018-06-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "stanza",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-11682",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-10T17:04:59.295180Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-798",
                    "description": "CWE-798 Use of Hard-coded Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-10T17:10:04.073Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:17:07.838Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://sadfud.me/explotos/CVE-2018-11629"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-06-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-27T17:43:44.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://sadfud.me/explotos/CVE-2018-11629"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11682",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://sadfud.me/explotos/CVE-2018-11629",
                  "refsource": "MISC",
                  "url": "http://sadfud.me/explotos/CVE-2018-11629"
                },
                {
                  "name": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/",
                  "refsource": "MISC",
                  "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
                },
                {
                  "name": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf",
                  "refsource": "MISC",
                  "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11682",
        "datePublished": "2018-06-02T13:00:00.000Z",
        "dateReserved": "2018-06-02T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:17:07.838Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11681 (GCVE-0-2018-11681)

    Vulnerability from nvd – Published: 2018-06-02 13:00 – Updated: 2024-08-05 08:17 Disputed
    VLAI
    Summary
    Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-04-23 18:06 UTC
    CWE
    • n/a
    • CWE-798 - Use of Hard-coded Credentials
    Impacted products
    Vendor Product Version
    lutron stanza_firmware Affected: -
        cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    lutron radiora_2_firmware Affected: -
        cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    lutron homeworks_qs_firmware Affected: -
        cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2018-06-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:lutron:stanza_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "stanza_firmware",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:lutron:radiora_2_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "radiora_2_firmware",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              },
              {
                "cpes": [
                  "cpe:2.3:o:lutron:homeworks_qs_firmware:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "homeworks_qs_firmware",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "-"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-11681",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-04-23T18:06:19.899664Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-798",
                    "description": "CWE-798 Use of Hard-coded Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-04T17:11:56.366Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:17:08.550Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://sadfud.me/explotos/CVE-2018-11629"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-06-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-27T17:40:51.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://sadfud.me/explotos/CVE-2018-11629"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11681",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** Default and unremovable support credentials (user:nwk password:nwk2) allow attackers to gain total super user control of an IoT device through a TELNET session to products using the RadioRA 2 Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://sadfud.me/explotos/CVE-2018-11629",
                  "refsource": "MISC",
                  "url": "http://sadfud.me/explotos/CVE-2018-11629"
                },
                {
                  "name": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/",
                  "refsource": "MISC",
                  "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
                },
                {
                  "name": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf",
                  "refsource": "MISC",
                  "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11681",
        "datePublished": "2018-06-02T13:00:00.000Z",
        "dateReserved": "2018-06-02T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:17:08.550Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-11682 (GCVE-0-2018-11682)

    Vulnerability from nvd – Published: 2018-06-02 13:00 – Updated: 2024-08-05 08:17 Disputed
    VLAI
    Summary
    Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2024-06-10 17:04 UTC
    CWE
    • n/a
    • CWE-798 - Use of Hard-coded Credentials
    Impacted products
    Vendor Product Version
    lutron stanza Affected: 0
        cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*
    Create a notification for this product.
    Date Public
    2018-06-02 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:h:lutron:stanza:-:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "stanza",
                "vendor": "lutron",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2018-11682",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-06-10T17:04:59.295180Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-798",
                    "description": "CWE-798 Use of Hard-coded Credentials",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-06-10T17:10:04.073Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          },
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T08:17:07.838Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://sadfud.me/explotos/CVE-2018-11629"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2018-06-02T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-06-27T17:43:44.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://sadfud.me/explotos/CVE-2018-11629"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
            }
          ],
          "tags": [
            "disputed"
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2018-11682",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "** DISPUTED ** Default and unremovable support credentials allow attackers to gain total super user control of an IoT device through a TELNET session to products using the Stanza Lutron integration protocol Revision M to Revision Y. NOTE: The vendor disputes this id as not being a vulnerability because what can be done through the ports revolve around controlling lighting, not code execution. A certain set of commands are listed, which bear some similarity to code, but they are not arbitrary and do not allow admin-level control of a machine."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "http://sadfud.me/explotos/CVE-2018-11629",
                  "refsource": "MISC",
                  "url": "http://sadfud.me/explotos/CVE-2018-11629"
                },
                {
                  "name": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/",
                  "refsource": "MISC",
                  "url": "https://reversecodes.wordpress.com/2018/06/02/0-day-tomando-el-control-de-las-instalaciones-de-la-nasa-en-cabo-canaveral/"
                },
                {
                  "name": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf",
                  "refsource": "MISC",
                  "url": "http://www.lutron.com/TechnicalDocumentLibrary/040249.pdf"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2018-11682",
        "datePublished": "2018-06-02T13:00:00.000Z",
        "dateReserved": "2018-06-02T00:00:00.000Z",
        "dateUpdated": "2024-08-05T08:17:07.838Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }