Search criteria
13 vulnerabilities by measuresoft
CVE-2024-3746 (GCVE-0-2024-3746)
Vulnerability from cvelistv5 – Published: 2024-04-30 19:45 – Updated: 2025-08-27 21:23
VLAI?
Summary
The entire parent directory - C:\ScadaPro and its sub-directories and
files are configured by default to allow user, including unprivileged
users, to write or overwrite files.
Severity ?
5.5 (Medium)
CWE
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro |
Affected:
6.9.0.0
|
Credits
Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA.
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-3746",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-03T19:21:37.188099Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-27T21:23:00.955Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:20:01.065Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ScadaPro",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "6.9.0.0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Sharon Brizinov of Claroty Team82 reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The entire parent directory - C:\\ScadaPro and its sub-directories and \nfiles are configured by default to allow user, including unprivileged \nusers, to write or overwrite files."
}
],
"value": "The entire parent directory - C:\\ScadaPro and its sub-directories and \nfiles are configured by default to allow user, including unprivileged \nusers, to write or overwrite files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-28T16:38:27.985Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-107-01"
}
],
"source": {
"advisory": "ICSA-24-107-01",
"discovery": "EXTERNAL"
},
"title": "Measuresoft ScadaPro Improper Access Control",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone.\n\n\u003cbr\u003e"
}
],
"value": "Measuresoft recommends that users manually reconfigure the vulnerable directories so that they are not writable by everyone."
}
],
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-3746",
"datePublished": "2024-04-30T19:45:21.951Z",
"dateReserved": "2024-04-12T20:04:14.046Z",
"dateUpdated": "2025-08-27T21:23:00.955Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-3263 (GCVE-0-2022-3263)
Vulnerability from cvelistv5 – Published: 2022-09-23 18:30 – Updated: 2025-04-16 17:47
VLAI?
Summary
The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges.
Severity ?
7.8 (High)
CWE
- CWE-284 - Improper Access Control
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server |
Affected:
6.7
|
Credits
@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:07:05.988Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-3263",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:27:10.852779Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:47:16.118Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "6.7"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
}
],
"datePublic": "2022-09-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284 Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-09-23T18:30:36.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Measuresoft ScadaPro Server Improper Access Control",
"workarounds": [
{
"lang": "en",
"value": "Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service:\n1. Open a command-line window (CMD) with \u0027run as administrator\u0027\n2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU)\n3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-09-22T20:45:00.000Z",
"ID": "CVE-2022-3263",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server Improper Access Control"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "6.7"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "@rgod777, working with Trend Micro Zero Day Initiative, reported this vulnerability to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-284 Improper Access Control"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-265-01"
}
]
},
"source": {
"discovery": "EXTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Measuresoft recommends the following steps to remove full access to the ORCHESTRATOR service:\n1. Open a command-line window (CMD) with \u0027run as administrator\u0027\n2. Use the following command to make the permission change to the ORCHESTRATOR service: sc sdset ORCHESTRATOR D:(A;;CCLCSWRPWPDTLOCRRC;;;SY)(A;;CCDCLCSWRPWPDTLOCRSDRCWDWO;;;BA)(A;;CCLCSWLOCRRC;;;IU)(A;;CCLCSWLOCRRC;;;SU)\n3. As a low-level user, attempt to shut down the ORCHESTRATOR service: sc stop ORCHESTRATOR. User will be denied. It will no longer be possible to edit the configuration of the service by a low-level user."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-3263",
"datePublished": "2022-09-23T18:30:36.700Z",
"dateReserved": "2022-09-21T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:47:16.118Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2894 (GCVE-0-2022-2894)
Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Summary
Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file.
Severity ?
7.8 (High)
CWE
- CWE-822 - Untrusted Pointer Dereference
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:59.982Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2894",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:27:25.266972Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:48:12.800Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2022-08-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-822",
"description": "CWE-822 Untrusted Pointer Dereference",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T20:54:55.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Measuresoft ScadaPro Server Untrusted Pointer Dereference",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
"ID": "CVE-2022-2894",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server Untrusted Pointer Dereference"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. The controls may allow seven untrusted pointer deference instances while processing a specific project file."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-822 Untrusted Pointer Dereference"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2894",
"datePublished": "2022-08-31T20:54:55.197Z",
"dateReserved": "2022-08-18T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:48:12.800Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2897 (GCVE-0-2022-2897)
Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Summary
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation..
Severity ?
7.8 (High)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server and Client |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:59.807Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2897",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:27:28.086217Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:48:20.720Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server and Client",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2022-08-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation.."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T20:54:55.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Measuresoft ScadaPro Server and Client Link Following",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
"ID": "CVE-2022-2897",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server and Client Link Following"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server and Client",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow privilege escalation.."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2897",
"datePublished": "2022-08-31T20:54:55.020Z",
"dateReserved": "2022-08-18T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:48:20.720Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2898 (GCVE-0-2022-2898)
Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 16:10
VLAI?
Summary
Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition.
Severity ?
6.1 (Medium)
CWE
- CWE-59 - Improper Link Resolution Before File Access ('Link Following')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server and Client |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:59.859Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2898",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:50:09.511855Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:10:51.543Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server and Client",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2022-08-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-59",
"description": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T20:54:55.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Measuresoft ScadaPro Server and Client Link Following",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
"ID": "CVE-2022-2898",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server and Client Link Following"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server and Client",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Measuresoft ScadaPro Server and Client (All Versions) do not properly resolve links before file access; this could allow a denial-of-service condition."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-59 Improper Link Resolution Before File Access (\u0027Link Following\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2898",
"datePublished": "2022-08-31T20:54:55.611Z",
"dateReserved": "2022-08-18T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:10:51.543Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2896 (GCVE-0-2022-2896)
Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Summary
Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:59.889Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2896",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:27:22.611560Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:48:01.170Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2022-08-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T20:54:55.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Measuresoft ScadaPro Server Use After Free",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
"ID": "CVE-2022-2896",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server Use After Free"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Measuresoft ScadaPro Server (All Versions) allows use after free while processing a specific project file."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2896",
"datePublished": "2022-08-31T20:54:55.401Z",
"dateReserved": "2022-08-18T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:48:01.170Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2895 (GCVE-0-2022-2895)
Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Summary
Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file.
Severity ?
7.8 (High)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:53:00.462Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2895",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:27:31.880992Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:48:31.475Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server",
"vendor": "Measuresoft",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"datePublic": "2022-08-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T20:54:54.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Measuresoft ScadaPro Server Stack-based Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
"ID": "CVE-2022-2895",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server Stack-based Buffer Overflow"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Measuresoft ScadaPro Server (All Versions) uses unmaintained ActiveX controls. These controls may allow two stack-based buffer overflow instances while processing a specific project file."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-121 Stack-based Buffer Overflow"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-06"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2895",
"datePublished": "2022-08-31T20:54:54.819Z",
"dateReserved": "2022-08-18T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:48:31.475Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2892 (GCVE-0-2022-2892)
Vulnerability from cvelistv5 – Published: 2022-08-31 20:54 – Updated: 2025-04-16 17:48
VLAI?
Summary
Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file.
Severity ?
7.8 (High)
CWE
- CWE-787 - Out-of-bounds Write
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Measuresoft | ScadaPro Server |
Affected:
All , < 6.8.0.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:52:59.497Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T17:27:34.723614Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T17:48:40.246Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "ScadaPro Server",
"vendor": "Measuresoft",
"versions": [
{
"lessThan": "6.8.0.1",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-08-23T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-31T20:54:54.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Measuresoft ScadaPro Server Out-of-bounds Write",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-08-23T18:30:00.000Z",
"ID": "CVE-2022-2892",
"STATE": "PUBLIC",
"TITLE": "Measuresoft ScadaPro Server Out-of-bounds Write"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ScadaPro Server",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "6.8.0.1"
}
]
}
}
]
},
"vendor_name": "Measuresoft"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Measuresoft ScadaPro Server (Versions prior to 6.8.0.1) uses an unmaintained ActiveX control, which may allow an out-of-bounds write condition while processing a specific project file."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787 Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-235-05"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2892",
"datePublished": "2022-08-31T20:54:54.536Z",
"dateReserved": "2022-08-18T00:00:00.000Z",
"dateUpdated": "2025-04-16T17:48:40.246Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2012-1824 (GCVE-0-2012-1824)
Vulnerability from cvelistv5 – Published: 2012-05-25 19:00 – Updated: 2024-09-16 19:19
VLAI?
Summary
Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T19:08:38.554Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-05-25T19:00:00Z",
"orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"shortName": "certcc"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cert@cert.org",
"ID": "CVE-2012-1824",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Untrusted search path vulnerability in Measuresoft ScadaPro Client before 4.0.0 and ScadaPro Server before 4.0.0 allows local users to gain privileges via a Trojan horse DLL in the current working directory."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc",
"refsource": "MISC",
"url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Client/DOCUMENTATION/ReleaseNotes.doc"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-145-01.pdf"
},
{
"name": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc",
"refsource": "MISC",
"url": "http://www.measuresoft.net/downloads/Measuresoft%20SCADA%204.4.6/issue_disks/Server/DOCUMENTATION/ReleaseNotes.doc"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
"assignerShortName": "certcc",
"cveId": "CVE-2012-1824",
"datePublished": "2012-05-25T19:00:00Z",
"dateReserved": "2012-03-21T00:00:00Z",
"dateUpdated": "2024-09-16T19:19:14.083Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-3495 (GCVE-0-2011-3495)
Vulnerability from cvelistv5 – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
VLAI?
Summary
Multiple directory traversal vulnerabilities in service.exe in Measuresoft ScadaPro 4.0.0 and earlier allow remote attackers to read, modify, or delete arbitrary files via the (1) RF, (2) wF, (3) UF, or (4) NF command.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:37:47.817Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON",
"x_transferred"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple directory traversal vulnerabilities in service.exe in Measuresoft ScadaPro 4.0.0 and earlier allow remote attackers to read, modify, or delete arbitrary files via the (1) RF, (2) wF, (3) UF, or (4) NF command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-02-14T10:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-3495",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple directory traversal vulnerabilities in service.exe in Measuresoft ScadaPro 4.0.0 and earlier allow remote attackers to read, modify, or delete arbitrary files via the (1) RF, (2) wF, (3) UF, or (4) NF command."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "8382",
"refsource": "SREASON",
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"name": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt",
"refsource": "MISC",
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-3495",
"datePublished": "2011-09-16T17:00:00",
"dateReserved": "2011-09-16T00:00:00",
"dateUpdated": "2024-08-06T23:37:47.817Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-3497 (GCVE-0-2011-3497)
Vulnerability from cvelistv5 – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
VLAI?
Summary
service.exe in Measuresoft ScadaPro 4.0.0 and earlier allows remote attackers to execute arbitrary DLL functions via the XF function, possibly related to an insecure exposed method.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:37:47.687Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON",
"x_transferred"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "service.exe in Measuresoft ScadaPro 4.0.0 and earlier allows remote attackers to execute arbitrary DLL functions via the XF function, possibly related to an insecure exposed method."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-02-14T10:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-3497",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "service.exe in Measuresoft ScadaPro 4.0.0 and earlier allows remote attackers to execute arbitrary DLL functions via the XF function, possibly related to an insecure exposed method."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "8382",
"refsource": "SREASON",
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"name": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt",
"refsource": "MISC",
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-3497",
"datePublished": "2011-09-16T17:00:00",
"dateReserved": "2011-09-16T00:00:00",
"dateUpdated": "2024-08-06T23:37:47.687Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-3496 (GCVE-0-2011-3496)
Vulnerability from cvelistv5 – Published: 2011-09-16 17:00 – Updated: 2024-08-06 23:37
VLAI?
Summary
service.exe in Measuresoft ScadaPro 4.0.0 and earlier allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) BF, (2) OF, or (3) EF command.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:37:47.830Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON",
"x_transferred"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "17848",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "http://www.exploit-db.com/exploits/17848"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "service.exe in Measuresoft ScadaPro 4.0.0 and earlier allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) BF, (2) OF, or (3) EF command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-02-14T10:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "17848",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "http://www.exploit-db.com/exploits/17848"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-3496",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "service.exe in Measuresoft ScadaPro 4.0.0 and earlier allows remote attackers to execute arbitrary commands via shell metacharacters in the (1) BF, (2) OF, or (3) EF command."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "8382",
"refsource": "SREASON",
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "17848",
"refsource": "EXPLOIT-DB",
"url": "http://www.exploit-db.com/exploits/17848"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"name": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt",
"refsource": "MISC",
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-3496",
"datePublished": "2011-09-16T17:00:00",
"dateReserved": "2011-09-16T00:00:00",
"dateUpdated": "2024-08-06T23:37:47.830Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2011-3490 (GCVE-0-2011-3490)
Vulnerability from cvelistv5 – Published: 2011-09-16 14:00 – Updated: 2024-08-06 23:37
VLAI?
Summary
Multiple stack-based buffer overflows in service.exe in Measuresoft ScadaPro 4.0.0 and earlier allow remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long command to port 11234, as demonstrated with the TF command.
Severity ?
No CVSS data available.
CWE
- n/a
Assigner
References
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T23:37:47.632Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON",
"x_transferred"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "17848",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "http://www.exploit-db.com/exploits/17848"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2011-09-13T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Multiple stack-based buffer overflows in service.exe in Measuresoft ScadaPro 4.0.0 and earlier allow remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long command to port 11234, as demonstrated with the TF command."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2012-02-14T10:00:00",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "8382",
"tags": [
"third-party-advisory",
"x_refsource_SREASON"
],
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "17848",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "http://www.exploit-db.com/exploits/17848"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2011-3490",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple stack-based buffer overflows in service.exe in Measuresoft ScadaPro 4.0.0 and earlier allow remote attackers to cause a denial of service (crash) and possibly execute arbitrary code via a long command to port 11234, as demonstrated with the TF command."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "8382",
"refsource": "SREASON",
"url": "http://securityreason.com/securityalert/8382"
},
{
"name": "17848",
"refsource": "EXPLOIT-DB",
"url": "http://www.exploit-db.com/exploits/17848"
},
{
"name": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf",
"refsource": "MISC",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-256-04.pdf"
},
{
"name": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt",
"refsource": "MISC",
"url": "http://aluigi.altervista.org/adv/scadapro_1-adv.txt"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2011-3490",
"datePublished": "2011-09-16T14:00:00",
"dateReserved": "2011-09-16T00:00:00",
"dateUpdated": "2024-08-06T23:37:47.632Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}