Search criteria

2 vulnerabilities by mitsubishi_electric

CVE-2015-3938 (GCVE-0-2015-3938)

Vulnerability from cvelistv5 – Published: 2015-10-03 10:00 – Updated: 2024-08-06 06:04
VLAI?
Summary
The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via a long parameter.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:04:00.944Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-146-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2015-09-29T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via a long parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2015-10-03T03:57:01",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-146-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2015-3938",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via a long parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-146-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-146-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-3938",
    "datePublished": "2015-10-03T10:00:00",
    "dateReserved": "2015-05-12T00:00:00",
    "dateUpdated": "2024-08-06T06:04:00.944Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2008-1546 (GCVE-0-2008-1546)

Vulnerability from cvelistv5 – Published: 2008-03-28 23:00 – Updated: 2024-08-07 08:24
VLAI?
Summary
servlet/MIMEReceiveServlet in the web controller for Mitsubishi Electric GB-50 and GB-50A air-conditioning control systems allows remote attackers to cause a denial of service (air-conditioning outage) via an XML document containing a setRequest command.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
References
http://www.securityfocus.com/bid/28406 vdb-entryx_refsource_BID
https://exchange.xforce.ibmcloud.com/vulnerabilit… vdb-entryx_refsource_XF
http://securityreason.com/securityalert/3794 third-party-advisoryx_refsource_SREASON
http://www.securityfocus.com/archive/1/489970/100… mailing-listx_refsource_BUGTRAQ
http://www.securityfocus.com/archive/1/483862/200… mailing-listx_refsource_BUGTRAQ
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-07T08:24:42.614Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "28406",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/28406"
          },
          {
            "name": "mitsubishielectric-gb50a-unath-access(41503)",
            "tags": [
              "vdb-entry",
              "x_refsource_XF",
              "x_transferred"
            ],
            "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/41503"
          },
          {
            "name": "3794",
            "tags": [
              "third-party-advisory",
              "x_refsource_SREASON",
              "x_transferred"
            ],
            "url": "http://securityreason.com/securityalert/3794"
          },
          {
            "name": "20080322 hacking the mitsubishi GB-50A",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/489970/100/0/threaded"
          },
          {
            "name": "20071117 security contact for mitsubishi electric?",
            "tags": [
              "mailing-list",
              "x_refsource_BUGTRAQ",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/archive/1/483862/2008-03-21/threaded"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2008-03-22T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "servlet/MIMEReceiveServlet in the web controller for Mitsubishi Electric GB-50 and GB-50A air-conditioning control systems allows remote attackers to cause a denial of service (air-conditioning outage) via an XML document containing a setRequest command."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-11T19:57:01",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "name": "28406",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/28406"
        },
        {
          "name": "mitsubishielectric-gb50a-unath-access(41503)",
          "tags": [
            "vdb-entry",
            "x_refsource_XF"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/41503"
        },
        {
          "name": "3794",
          "tags": [
            "third-party-advisory",
            "x_refsource_SREASON"
          ],
          "url": "http://securityreason.com/securityalert/3794"
        },
        {
          "name": "20080322 hacking the mitsubishi GB-50A",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/489970/100/0/threaded"
        },
        {
          "name": "20071117 security contact for mitsubishi electric?",
          "tags": [
            "mailing-list",
            "x_refsource_BUGTRAQ"
          ],
          "url": "http://www.securityfocus.com/archive/1/483862/2008-03-21/threaded"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2008-1546",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "servlet/MIMEReceiveServlet in the web controller for Mitsubishi Electric GB-50 and GB-50A air-conditioning control systems allows remote attackers to cause a denial of service (air-conditioning outage) via an XML document containing a setRequest command."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "28406",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/28406"
            },
            {
              "name": "mitsubishielectric-gb50a-unath-access(41503)",
              "refsource": "XF",
              "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/41503"
            },
            {
              "name": "3794",
              "refsource": "SREASON",
              "url": "http://securityreason.com/securityalert/3794"
            },
            {
              "name": "20080322 hacking the mitsubishi GB-50A",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/489970/100/0/threaded"
            },
            {
              "name": "20071117 security contact for mitsubishi electric?",
              "refsource": "BUGTRAQ",
              "url": "http://www.securityfocus.com/archive/1/483862/2008-03-21/threaded"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2008-1546",
    "datePublished": "2008-03-28T23:00:00",
    "dateReserved": "2008-03-28T00:00:00",
    "dateUpdated": "2024-08-07T08:24:42.614Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}