Search criteria

5 vulnerabilities by monroe_electronics

CVE-2013-4732 (GCVE-0-2013-4732)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-16 17:54
VLAI?
Summary
The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network. NOTE: VU#662676 states "Monroe Electronics could not reproduce this finding.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.001Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        }
      ],
      "tags": [
        "disputed"
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4732",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "** DISPUTED ** The administrative web server on the Digital Alert Systems DASDEC EAS device through 2.0-2 and the Monroe Electronics R189 One-Net EAS device through 2.0-2 uses predictable session ID values, which makes it easier for remote attackers to hijack sessions by sniffing the network.  NOTE: VU#662676 states \"Monroe Electronics could not reproduce this finding.\""
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "MISC",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "MISC",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "MISC",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "MISC",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4732",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-16T17:54:12.663Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-0137 (GCVE-0-2013-0137)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-08-06 14:18
VLAI?
Summary
The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T14:18:09.572Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2013-06-24T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-29T17:01:40",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cert@cert.org",
          "ID": "CVE-2013-0137",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The default configuration of the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 contains a known SSH private key, which makes it easier for remote attackers to obtain root access, and spoof alerts, via an SSH session."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/",
              "refsource": "MISC",
              "url": "https://securityledger.com/2020/01/seven-years-later-scores-of-eas-systems-sit-un-patched-vulnerable/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2013-0137",
    "datePublished": "2013-06-29T21:00:00",
    "dateReserved": "2012-12-06T00:00:00",
    "dateUpdated": "2024-08-06T14:18:09.572Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4735 (GCVE-0-2013-4735)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 02:57
VLAI?
Summary
The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.034Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4735",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 have a default password for an administrative account, which makes it easier for remote attackers to obtain access via an IP network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4735",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T02:57:08.864Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4733 (GCVE-0-2013-4733)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 04:04
VLAI?
Summary
The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:26.967Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4733",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 allows remote attackers to obtain sensitive configuration and status information by reading log files."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4733",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T04:04:17.436Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2013-4734 (GCVE-0-2013-4734)

Vulnerability from cvelistv5 – Published: 2013-06-29 21:00 – Updated: 2024-09-17 01:31
VLAI?
Summary
dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors.
Severity ?
No CVSS data available.
CWE
  • n/a
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T16:52:27.167Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
          },
          {
            "name": "VU#662676",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT-VN",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/662676"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2013-06-29T21:00:00Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
        },
        {
          "name": "VU#662676",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT-VN"
          ],
          "url": "http://www.kb.cert.org/vuls/id/662676"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2013-4734",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "dasdec_mkuser on the Digital Alert Systems DASDEC EAS device before 2.0-2 and the Monroe Electronics R189 One-Net EAS device before 2.0-2 generates predictable passwords, which might make it easier for attackers to obtain non-administrative access via unspecified vectors."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MUK2"
            },
            {
              "name": "VU#662676",
              "refsource": "CERT-VN",
              "url": "http://www.kb.cert.org/vuls/id/662676"
            },
            {
              "name": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H",
              "refsource": "CONFIRM",
              "url": "http://www.kb.cert.org/vuls/id/AAMN-98MU7H"
            },
            {
              "name": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.monroe-electronics.com/MONROE_ELECTRONICS_PDF/130604-Monroe-Security-PR.pdf"
            },
            {
              "name": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.digitalalertsystems.com/pdf/130604-Monroe-Security-PR.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2013-4734",
    "datePublished": "2013-06-29T21:00:00Z",
    "dateReserved": "2013-06-29T00:00:00Z",
    "dateUpdated": "2024-09-17T01:31:37.062Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}