Search criteria
1 vulnerability by nmfc
CVE-2020-14514 (GCVE-0-2020-14514)
Vulnerability from cvelistv5 – Published: 2020-09-01 14:00 – Updated: 2024-08-04 12:46
VLAI?
Summary
All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements.
Severity ?
4.3 (Medium)
CWE
- CWE-201 - EXPOSURE OF SENSITIVE INFORMATION THROUGH SENT DATA CWE-201
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Multiple Vendors All trailer power line communications are affected. | Trailer Power Line Communications |
Affected:
All trailer power line communications are affected.
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T12:46:34.636Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Trailer Power Line Communications",
"vendor": "Multiple Vendors All trailer power line communications are affected.",
"versions": [
{
"status": "affected",
"version": "All trailer power line communications are affected."
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-201",
"description": "EXPOSURE OF SENSITIVE INFORMATION THROUGH SENT DATA CWE-201",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-09-01T14:00:45",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Trailer Power Line Communications vulnerability",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-14514",
"STATE": "PUBLIC",
"TITLE": "Trailer Power Line Communications vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Trailer Power Line Communications",
"version": {
"version_data": [
{
"version_value": "All trailer power line communications are affected."
}
]
}
}
]
},
"vendor_name": "Multiple Vendors All trailer power line communications are affected."
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "All trailer Power Line Communications are affected. PLC bus traffic can be sniffed reliably via an active antenna up to 6 feet away. Further distances are also possible, subject to environmental conditions and receiver improvements."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "EXPOSURE OF SENSITIVE INFORMATION THROUGH SENT DATA CWE-201"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01",
"refsource": "MISC",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-219-01"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-14514",
"datePublished": "2020-09-01T14:00:45",
"dateReserved": "2020-06-19T00:00:00",
"dateUpdated": "2024-08-04T12:46:34.636Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}