Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
3 vulnerabilities by omnis
CVE-2023-38334 (GCVE-0-2023-38334)
Vulnerability from cvelistv5 – Published: 2023-07-20 00:00 – Updated: 2024-10-24 20:33
VLAI
Summary
Omnis Studio 10.22.00 has incorrect access control. It advertises an irreversible feature for locking classes within Omnis libraries: it should be no longer possible to delete, view, change, copy, rename, duplicate, or print a locked class. Due to implementation issues, locked classes in Omnis libraries can be unlocked, and thus further analyzed and modified by Omnis Studio. This allows for further analyzing and also deleting, viewing, changing, copying, renaming, duplicating, or printing previously locked Omnis classes. This violates the expected behavior of an "irreversible operation."
Severity
No CVSS data available.
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-276 - Incorrect Default Permissions
Assigner
References
4 references
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:39:12.696Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2023-006.txt"
},
{
"name": "20230721 [SYSS-2023-006]: Omnis Studio - Expected Behavior Violation (CWE-440) (CVE-2023-38334)",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/42"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/173696/Omnis-Studio-10.22.00-Library-Unlock.html"
},
{
"name": "20230724 APPLE-SA-2023-07-24-1 Safari 16.6",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/43"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38334",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-24T20:32:04.757110Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-24T20:33:37.525Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Omnis Studio 10.22.00 has incorrect access control. It advertises an irreversible feature for locking classes within Omnis libraries: it should be no longer possible to delete, view, change, copy, rename, duplicate, or print a locked class. Due to implementation issues, locked classes in Omnis libraries can be unlocked, and thus further analyzed and modified by Omnis Studio. This allows for further analyzing and also deleting, viewing, changing, copying, renaming, duplicating, or printing previously locked Omnis classes. This violates the expected behavior of an \"irreversible operation.\""
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-26T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2023-006.txt"
},
{
"name": "20230721 [SYSS-2023-006]: Omnis Studio - Expected Behavior Violation (CWE-440) (CVE-2023-38334)",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/42"
},
{
"url": "http://packetstormsecurity.com/files/173696/Omnis-Studio-10.22.00-Library-Unlock.html"
},
{
"name": "20230724 APPLE-SA-2023-07-24-1 Safari 16.6",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/43"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38334",
"datePublished": "2023-07-20T00:00:00.000Z",
"dateReserved": "2023-07-14T00:00:00.000Z",
"dateUpdated": "2024-10-24T20:33:37.525Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-38335 (GCVE-0-2023-38335)
Vulnerability from cvelistv5 – Published: 2023-07-20 00:00 – Updated: 2024-10-24 20:28
VLAI
Summary
Omnis Studio 10.22.00 has incorrect access control. It advertises a feature for making Omnis libraries "always private" - this is supposed to be an irreversible operation. However, due to implementation issues, "always private" Omnis libraries can be opened by the Omnis Studio browser by bypassing specific checks. This violates the expected behavior of an "irreversible operation".
Severity
No CVSS data available.
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- n/a
- CWE-276 - Incorrect Default Permissions
Assigner
References
4 references
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T17:39:12.753Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2023-005.txt"
},
{
"name": "20230721 [SYSS-2023-005]: Omnis Studio - Expected Behavior Violation (CWE-440) (CVE-2023-38335)",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/41"
},
{
"tags": [
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/173695/Omnis-Studio-10.22.00-Library-Setting-Bypass.html"
},
{
"name": "20230724 APPLE-SA-2023-07-24-1 Safari 16.6",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/43"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-38335",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-24T20:25:18.168515Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-10-24T20:28:58.255Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Omnis Studio 10.22.00 has incorrect access control. It advertises a feature for making Omnis libraries \"always private\" - this is supposed to be an irreversible operation. However, due to implementation issues, \"always private\" Omnis libraries can be opened by the Omnis Studio browser by bypassing specific checks. This violates the expected behavior of an \"irreversible operation\"."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-26T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2023-005.txt"
},
{
"name": "20230721 [SYSS-2023-005]: Omnis Studio - Expected Behavior Violation (CWE-440) (CVE-2023-38335)",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/41"
},
{
"url": "http://packetstormsecurity.com/files/173695/Omnis-Studio-10.22.00-Library-Setting-Bypass.html"
},
{
"name": "20230724 APPLE-SA-2023-07-24-1 Safari 16.6",
"tags": [
"mailing-list"
],
"url": "http://seclists.org/fulldisclosure/2023/Jul/43"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-38335",
"datePublished": "2023-07-20T00:00:00.000Z",
"dateReserved": "2023-07-14T00:00:00.000Z",
"dateUpdated": "2024-10-24T20:28:58.255Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2000-0449 (GCVE-0-2000-0449)
Vulnerability from cvelistv5 – Published: 2000-06-15 04:00 – Updated: 2024-08-08 05:21
VLAI
Summary
Omnis Studio 2.4 uses weak encryption (trivial encoding) for encrypting database fields.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/1255 | vdb-entryx_refsource_BID |
| http://archives.neohapsis.com/archives/bugtraq/20… | mailing-listx_refsource_BUGTRAQ |
Date Public
2000-05-25 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-08T05:21:30.473Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "1255",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/1255"
},
{
"name": "20000525 Omnis Weak Encryption - Many products affected",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ",
"x_transferred"
],
"url": "http://archives.neohapsis.com/archives/bugtraq/2000-05/0311.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2000-05-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Omnis Studio 2.4 uses weak encryption (trivial encoding) for encrypting database fields."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2003-03-21T10:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"name": "1255",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/1255"
},
{
"name": "20000525 Omnis Weak Encryption - Many products affected",
"tags": [
"mailing-list",
"x_refsource_BUGTRAQ"
],
"url": "http://archives.neohapsis.com/archives/bugtraq/2000-05/0311.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2000-0449",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Omnis Studio 2.4 uses weak encryption (trivial encoding) for encrypting database fields."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "1255",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/1255"
},
{
"name": "20000525 Omnis Weak Encryption - Many products affected",
"refsource": "BUGTRAQ",
"url": "http://archives.neohapsis.com/archives/bugtraq/2000-05/0311.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2000-0449",
"datePublished": "2000-06-15T04:00:00.000Z",
"dateReserved": "2000-06-14T00:00:00.000Z",
"dateUpdated": "2024-08-08T05:21:30.473Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}