Search
Find a vulnerability
Search criteria
ⓘ
Use this form to refine search results.
Full-text search supports keyword queries with ranking and filtering.
You can combine vendor, product, and sources to narrow results.
Enable “Apply ordering” to sort by date instead of relevance.
3 vulnerabilities by proges
CVE-2024-31203 (GCVE-0-2024-31203)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:18 – Updated: 2024-09-30 14:09
VLAI
Summary
A “CWE-121: Stack-based Buffer Overflow” in the wd210std.dll dynamic library packaged with the ThermoscanIP installer allows a local attacker to possibly trigger a Denial-of-Service (DoS) condition on the target component.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Plug&Track | Thermoscan IP |
Affected:
20211103
(semver)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31203",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T18:38:03.656374Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T18:38:15.155Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"platforms": [
"Windows"
],
"product": "Thermoscan IP",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "20211103",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-121: Stack-based Buffer Overflow\u201d in the wd210std.dll dynamic library packaged with the ThermoscanIP installer allows a local attacker to possibly trigger a Denial-of-Service (DoS) condition on the target component."
}
],
"value": "A \u201cCWE-121: Stack-based Buffer Overflow\u201d in the wd210std.dll dynamic library packaged with the ThermoscanIP installer allows a local attacker to possibly trigger a Denial-of-Service (DoS) condition on the target component."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:09:39.568Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31203"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31203",
"datePublished": "2024-07-31T13:18:24.871Z",
"dateReserved": "2024-03-29T08:32:14.700Z",
"dateUpdated": "2024-09-30T14:09:39.568Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31202 (GCVE-0-2024-31202)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:17 – Updated: 2024-09-30 14:08
VLAI
Summary
A “CWE-732: Incorrect Permission Assignment for Critical Resource” in the ThermoscanIP installation folder allows a local attacker to perform a Local Privilege Escalation.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-732 - Incorrect Permission Assignment for Critical Resource
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Plug&Track | Thermoscan IP |
Affected:
20211103
(semver)
|
|
| plug\&track | thermoscan_ip |
Affected:
20211103
cpe:2.3:a:plug\&track:thermoscan_ip:20211103:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:plug\\\u0026track:thermoscan_ip:20211103:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "thermoscan_ip",
"vendor": "plug\\\u0026track",
"versions": [
{
"status": "affected",
"version": "20211103"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31202",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-31T16:12:35.449038Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T16:16:50.255Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"platforms": [
"Windows"
],
"product": "Thermoscan IP",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "20211103",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-732: Incorrect Permission Assignment for Critical Resource\u201d in the ThermoscanIP installation folder allows a local attacker to perform a Local Privilege Escalation."
}
],
"value": "A \u201cCWE-732: Incorrect Permission Assignment for Critical Resource\u201d in the ThermoscanIP installation folder allows a local attacker to perform a Local Privilege Escalation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732 Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-30T14:08:22.100Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31202"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31202",
"datePublished": "2024-07-31T13:17:59.411Z",
"dateReserved": "2024-03-29T08:32:14.699Z",
"dateUpdated": "2024-09-30T14:08:22.100Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-31201 (GCVE-0-2024-31201)
Vulnerability from cvelistv5 – Published: 2024-07-31 13:17 – Updated: 2024-08-01 14:52
VLAI
Summary
A “CWE-428: Unquoted Search Path or Element” affects the ThermoscanIP_Scrutation service. Such misconfiguration could be abused in scenarios where incorrect permissions were assigned to the C:\ path to attempt a privilege escalation on the local machine.
Severity
6.5 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-428 - Unquoted Search Path or Element
Assigner
References
1 reference
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Plug&Track | Thermoscan IP |
Affected:
20211103
(semver)
|
|
| plug_and_track | thermoscan_ip |
Affected:
20211103
cpe:2.3:a:plug_and_track:thermoscan_ip:*:*:*:*:*:*:*:* |
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:plug_and_track:thermoscan_ip:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "thermoscan_ip",
"vendor": "plug_and_track",
"versions": [
{
"status": "affected",
"version": "20211103"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-31201",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T14:50:54.714006Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T14:52:47.793Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"platforms": [
"Windows"
],
"product": "Thermoscan IP",
"vendor": "Plug\u0026Track",
"versions": [
{
"status": "affected",
"version": "20211103",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Diego Zaffaroni of Nozomi Networks found this bug during a security research activity."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A \u201cCWE-428: Unquoted Search Path or Element\u201d affects the ThermoscanIP_Scrutation service. Such misconfiguration could be abused in scenarios where incorrect permissions were assigned to the C:\\ path to attempt a privilege escalation on the local machine."
}
],
"value": "A \u201cCWE-428: Unquoted Search Path or Element\u201d affects the ThermoscanIP_Scrutation service. Such misconfiguration could be abused in scenarios where incorrect permissions were assigned to the C:\\ path to attempt a privilege escalation on the local machine."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-428",
"description": "CWE-428 Unquoted Search Path or Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-31T13:17:30.914Z",
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi"
},
"references": [
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-31201"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "No official patch available from vendor. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"value": "No official patch available from vendor. Conduct regular and thorough reviews of logs and user accounts on systems running the Thermoscan IP software. This will help identify and address any suspicious activities early, ensuring that any potential security breaches are caught and remediated swiftly."
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"assignerShortName": "Nozomi",
"cveId": "CVE-2024-31201",
"datePublished": "2024-07-31T13:17:30.914Z",
"dateReserved": "2024-03-29T08:32:14.699Z",
"dateUpdated": "2024-08-01T14:52:47.793Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}