CVE-2020-5328
Vulnerability from cvelistv5
Published
2020-03-06 20:25
Modified
2024-09-16 18:29
Severity ?
EPSS score ?
Summary
Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Dell | Isilon OneFS |
Version: unspecified < 8.2.0 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T08:22:09.299Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_MISC", "x_transferred" ], "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "Isilon OneFS", "vendor": "Dell", "versions": [ { "lessThan": "8.2.0", "status": "affected", "version": "unspecified", "versionType": "custom" } ] } ], "datePublic": "2020-02-20T00:00:00", "descriptions": [ { "lang": "en", "value": "Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-306", "description": "CWE-306: Missing Authentication for Critical Function", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2020-03-06T20:25:14", "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "shortName": "dell" }, "references": [ { "tags": [ "x_refsource_MISC" ], "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability" } ], "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "secure@dell.com", "DATE_PUBLIC": "2020-02-20", "ID": "CVE-2020-5328", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Isilon OneFS", "version": { "version_data": [ { "version_affected": "\u003c", "version_value": "8.2.0" } ] } } ] }, "vendor_name": "Dell" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur." } ] }, "impact": { "cvss": { "baseScore": 9.8, "baseSeverity": "Critical", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-306: Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability", "refsource": "MISC", "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability" } ] } } } }, "cveMetadata": { "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe", "assignerShortName": "dell", "cveId": "CVE-2020-5328", "datePublished": "2020-03-06T20:25:14.219804Z", "dateReserved": "2020-01-03T00:00:00", "dateUpdated": "2024-09-16T18:29:46.134Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "fkie_nvd": { "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:emc_isilon_onefs:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"8.2.0\", \"matchCriteriaId\": \"CD96069B-3830-4B02-860F-BC9D0A5914FE\"}]}]}]", "descriptions": "[{\"lang\": \"en\", \"value\": \"Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.\"}, {\"lang\": \"es\", \"value\": \"Dell EMC Isilon OneFS versiones anteriores a 8.2.0, contienen una vulnerabilidad de acceso no autorizado debido a una falta de comprobaciones de autorizaci\\u00f3n exhaustivas cuando SyncIQ es licenciada, pero las sincronizaciones cifradas no son marcadas como requeridas. Cuando esto se presenta, puede ocurrir una p\\u00e9rdida de control del cl\\u00faster.\"}]", "id": "CVE-2020-5328", "lastModified": "2024-11-21T05:33:55.317", "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 9.8, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 10.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 10.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}", "published": "2020-03-06T21:15:15.687", "references": "[{\"url\": \"https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]", "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-306\"}]}]" }, "nvd": "{\"cve\":{\"id\":\"CVE-2020-5328\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2020-03-06T21:15:15.687\",\"lastModified\":\"2024-11-21T05:33:55.317\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.\"},{\"lang\":\"es\",\"value\":\"Dell EMC Isilon OneFS versiones anteriores a 8.2.0, contienen una vulnerabilidad de acceso no autorizado debido a una falta de comprobaciones de autorizaci\u00f3n exhaustivas cuando SyncIQ es licenciada, pero las sincronizaciones cifradas no son marcadas como requeridas. Cuando esto se presenta, puede ocurrir una p\u00e9rdida de control del cl\u00faster.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":10.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:emc_isilon_onefs:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"8.2.0\",\"matchCriteriaId\":\"CD96069B-3830-4B02-860F-BC9D0A5914FE\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.