CVE-2022-1372
Vulnerability from cvelistv5
Published
2022-05-02 18:08
Modified
2024-08-03 00:03
Severity ?
Summary
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
References
ics-cert@hq.dhs.govhttps://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01Mitigation, Third Party Advisory, US Government Resource
Impacted products
Delta ElectronicsDIAEnergie
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:03:05.802Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DIAEnergie",
          "vendor": "Delta Electronics",
          "versions": [
            {
              "lessThan": "1.8.02.004",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-89",
              "description": "CWE-89 SQL Injection",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-02T18:08:06",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
        }
      ],
      "source": {
        "advisory": "ICSA-22-081-01",
        "discovery": "UNKNOWN"
      },
      "workarounds": [
        {
          "lang": "en",
          "value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2022-1372",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DIAEnergie",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "1.8.02.004"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Delta Electronics"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Michael Heinzl and Dusan Stevanovic of Trend Micro\u2019s Zero Day Initiative reported these vulnerabilities to CISA."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-89 SQL Injection"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Delta Electronics has fixed the reported vulnerabilities in Version 1.08.02.004. Users should contact Delta customer service or a Delta representative for this release, as it will not be released publicly. Delta is working on a public release that will include these fixes and other features on June 30, 2022."
          }
        ],
        "source": {
          "advisory": "ICSA-22-081-01",
          "discovery": "UNKNOWN"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "Delta also suggests users:\n\nMinimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet.\nLocate control system networks and remote devices behind firewalls and isolate them from the business network.\nUse an application firewall that can detect attacks against \u201cPath Traversal\u201d and \u201cSQL Injection\u201d weakness.\nNever connect programming software to any network other than the network intended for that device.\nWhen remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing a VPN is only as secure as its connected devices"
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-1372",
    "datePublished": "2022-05-02T18:08:06",
    "dateReserved": "2022-04-14T00:00:00",
    "dateUpdated": "2024-08-03T00:03:05.802Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-1372\",\"sourceIdentifier\":\"ics-cert@hq.dhs.gov\",\"published\":\"2022-05-02T19:15:08.620\",\"lastModified\":\"2022-05-10T19:59:16.013\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in dlSlog.aspx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.\"},{\"lang\":\"es\",\"value\":\"Delta Electronics DIAEnergie (Todas las versiones anteriores a la 1.8.02.004) presenta una vulnerabilidad de inyecci\u00f3n SQL ciega en el archivo dlSlog.aspx. Esto permite a un atacante inyectar consultas SQL arbitrarias, recuperar y modificar el contenido de la base de datos y ejecutar comandos del sistema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:C/I:C/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":10.0},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":10.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]},{\"source\":\"ics-cert@hq.dhs.gov\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-89\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"1.8.02.004\",\"matchCriteriaId\":\"BFE259F4-C6EC-41EE-B1E1-693C9248931F\"}]}]}],\"references\":[{\"url\":\"https://www.cisa.gov/uscert/ics/advisories/icsa-22-081-01\",\"source\":\"ics-cert@hq.dhs.gov\",\"tags\":[\"Mitigation\",\"Third Party Advisory\",\"US Government Resource\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.