CVE-2022-33138
Vulnerability from cvelistv5
Published
2022-07-12 10:06
Modified
2024-08-03 08:01
Severity
Summary
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T08:01:19.531Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SIMATIC MV540 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV540 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV550 H",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV550 S",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV560 U",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        },
        {
          "product": "SIMATIC MV560 X",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.3"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-12T10:06:46",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-33138",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SIMATIC MV540 H",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV540 S",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV550 H",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV550 S",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV560 U",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIMATIC MV560 X",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V3.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-33138",
    "datePublished": "2022-07-12T10:06:46",
    "dateReserved": "2022-06-13T00:00:00",
    "dateUpdated": "2024-08-03T08:01:19.531Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-33138\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2022-07-12T10:15:10.757\",\"lastModified\":\"2022-07-15T17:31:16.187\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). Affected devices do not perform authentication for several web API endpoints. This could allow an unauthenticated remote attacker to read and download data from the device.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en SIMATIC MV540 H (Todas las versiones anteriores a V3.3), SIMATIC MV540 S (Todas las versiones anteriores a V3.3), SIMATIC MV550 H (Todas las versiones anteriores a V3.3), SIMATIC MV550 S (Todas las versiones anteriores a V3.3), SIMATIC MV560 U (Todas las versiones anteriores a V3.3), SIMATIC MV560 X (Todas las versiones anteriores a V3.3). Los dispositivos afectados no llevan a cabo la autenticaci\u00f3n para varios endpoints de la API web. Esto podr\u00eda permitir a un atacante remoto no autenticado leer y descargar datos del dispositivo\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:N/C:P/I:N/A:N\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":5.0},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":10.0,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv540_h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"A6527D89-4A8F-4A97-B2E9-CFBC9593DEB7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18944887-DE3F-4FB4-88D2-1C8EC89A1481\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv540_s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"0557AB45-C9F1-4F67-BD8D-E5AD706CCACF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B016178-2DCB-417C-B20F-8B9E1904BE8C\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv550_h_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"7EFEE0CC-F494-4B57-8DF1-68954C4AA144\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"324A87A6-2DC6-4797-8191-0BE2D8D1F9FC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv550_s_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"AC4115D9-D589-4EE4-AFC8-D3C103A84DA2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4B6E1134-8C21-4045-BD02-F44250474C40\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv560_u_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"E9DEAF0E-48DB-4499-835B-96E17B8DD738\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D2FBB8F8-C886-4A2B-8808-6E3D6A57B271\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:siemens:simatic_mv560_x_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"3.3\",\"matchCriteriaId\":\"99359BFA-BBA9-423F-A12B-1E9AF673CB91\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DAA25C73-59D0-469D-BE6F-6188F645C1D9\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}