CVE-2022-36781
Vulnerability from cvelistv5
Published
2022-09-28 19:11
Modified
2024-09-16 20:16
Summary
ConnectWise ScreenConnect versions 22.6 and below contained a flaw allowing potential brute force attacks on custom access tokens due to inadequate rate-limiting controls in the default configuration. Attackers could exploit this vulnerability to gain unauthorized access by repeatedly attempting access code combinations. ConnectWise has addressed this issue in later versions by implementing rate-limiting controls as a preventive measure against brute force attacks.
Impacted products
Vendor Product Version
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T10:14:28.402Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ScreenConnect",
          "vendor": "ConnectWise",
          "versions": [
            {
              "lessThan": "22.6*",
              "status": "affected",
              "version": "22.7",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gad Abuhatziera Sophtix Security LTD"
        }
      ],
      "datePublic": "2022-09-10T21:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eConnectWise ScreenConnect versions 22.6 and below contained a flaw allowing potential brute force attacks on custom access tokens due to inadequate rate-limiting controls in the default configuration. Attackers could exploit this vulnerability to gain unauthorized access by repeatedly attempting access code combinations. ConnectWise has addressed this issue in later versions by implementing rate-limiting controls as a preventive measure against brute force attacks.\u003c/p\u003e"
            }
          ],
          "value": "ConnectWise ScreenConnect versions 22.6 and below contained a flaw allowing potential brute force attacks on custom access tokens due to inadequate rate-limiting controls in the default configuration. Attackers could exploit this vulnerability to gain unauthorized access by repeatedly attempting access code combinations. ConnectWise has addressed this issue in later versions by implementing rate-limiting controls as a preventive measure against brute force attacks."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Session Code Bypass",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-14T13:48:41.228Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eUpdate to version 22.7.\u003c/p\u003e"
            }
          ],
          "value": "Update to version 22.7."
        }
      ],
      "source": {
        "defect": [
          "ILVN-2022-0052"
        ],
        "discovery": "EXTERNAL"
      },
      "title": "ConnectWise - ScreenConnect Session Code Bypass",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2022-36781",
    "datePublished": "2022-09-28T19:11:20.650962Z",
    "dateReserved": "2022-07-26T00:00:00",
    "dateUpdated": "2024-09-16T20:16:20.390Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:connectwise:screenconnect:*:*:*:*:*:*:*:*\", \"versionEndExcluding\": \"22.7\", \"matchCriteriaId\": \"3298FD82-256A-462F-BA65-FAF3DF1BC6ED\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"ConnectWise ScreenConnect versions 22.6 and below contained a flaw allowing potential brute force attacks on custom access tokens due to inadequate rate-limiting controls in the default configuration. Attackers could exploit this vulnerability to gain unauthorized access by repeatedly attempting access code combinations. ConnectWise has addressed this issue in later versions by implementing rate-limiting controls as a preventive measure against brute force attacks.\"}, {\"lang\": \"es\", \"value\": \"WiseConnect - Una Omisi\\u00f3n de C\\u00f3digo de Cesi\\u00f3n de ScreenConnect. Un atacante tendr\\u00eda que usar un proxy para monitorizar el tr\\u00e1fico, y llevar a cabo una fuerza bruta en el c\\u00f3digo de sesi\\u00f3n para poder entrar. Datos confidenciales sobre la empresa , entrar en una sesi\\u00f3n\"}]",
      "id": "CVE-2022-36781",
      "lastModified": "2024-11-21T07:13:42.880",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"cna@cyber.gov.il\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 3.9, \"impactScore\": 1.4}]}",
      "published": "2022-09-28T20:15:11.857",
      "references": "[{\"url\": \"https://www.gov.il/en/Departments/faq/cve_advisories\", \"source\": \"cna@cyber.gov.il\", \"tags\": [\"Third Party Advisory\"]}, {\"url\": \"https://www.gov.il/en/Departments/faq/cve_advisories\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Third Party Advisory\"]}]",
      "sourceIdentifier": "cna@cyber.gov.il",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-307\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2022-36781\",\"sourceIdentifier\":\"cna@cyber.gov.il\",\"published\":\"2022-09-28T20:15:11.857\",\"lastModified\":\"2024-11-21T07:13:42.880\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"ConnectWise ScreenConnect versions 22.6 and below contained a flaw allowing potential brute force attacks on custom access tokens due to inadequate rate-limiting controls in the default configuration. Attackers could exploit this vulnerability to gain unauthorized access by repeatedly attempting access code combinations. ConnectWise has addressed this issue in later versions by implementing rate-limiting controls as a preventive measure against brute force attacks.\"},{\"lang\":\"es\",\"value\":\"WiseConnect - Una Omisi\u00f3n de C\u00f3digo de Cesi\u00f3n de ScreenConnect. Un atacante tendr\u00eda que usar un proxy para monitorizar el tr\u00e1fico, y llevar a cabo una fuerza bruta en el c\u00f3digo de sesi\u00f3n para poder entrar. Datos confidenciales sobre la empresa , entrar en una sesi\u00f3n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cna@cyber.gov.il\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":3.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-307\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:connectwise:screenconnect:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"22.7\",\"matchCriteriaId\":\"3298FD82-256A-462F-BA65-FAF3DF1BC6ED\"}]}]}],\"references\":[{\"url\":\"https://www.gov.il/en/Departments/faq/cve_advisories\",\"source\":\"cna@cyber.gov.il\",\"tags\":[\"Third Party Advisory\"]},{\"url\":\"https://www.gov.il/en/Departments/faq/cve_advisories\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Third Party Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.