CVE-2023-3595
Vulnerability from cvelistv5
Published
2023-07-12 12:37
Modified
2024-08-02 07:01
Severity ?
EPSS score ?
Summary
Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution
References
▼ | URL | Tags | |
---|---|---|---|
PSIRT@rockwellautomation.com | https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010 | Permissions Required, Vendor Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:01:57.031Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "1756-EN2T Series A, B, C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2T Series D", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TK Series A, B, C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TXT Series A, B, C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TXT Series D", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TP Series A", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TPK Series A", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TPXT Series A", "vendor": "Rockwell Auotmation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TR Series A, B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TR Series C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TRK Series A, B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TRK Series C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TRXT Series A, B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2TRXT Series C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2F Series A, B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2F Series C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2FK Series A, B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN2FK Series C", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN3TR Series A", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN3TR Series B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN3TRK Series A", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=5.008 \u0026 5.028" } ] }, { "defaultStatus": "unaffected", "product": "1756-EN3TRK Series B", "vendor": "Rockwell Automation", "versions": [ { "status": "affected", "version": "\u003c=11.003" } ] } ], "datePublic": "2023-07-12T12:00:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\u003c/span\u003e\n\n" } ], "value": "\nWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\n\n" } ], "impacts": [ { "capecId": "CAPEC-100", "descriptions": [ { "lang": "en", "value": "CAPEC-100 Overflow Buffers" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-787", "description": "CWE-787 Out-of-bounds Write", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-07-12T13:15:20.247Z", "orgId": "b73dd486-f505-4403-b634-40b078b177f0", "shortName": "Rockwell" }, "references": [ { "url": "https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010" } ], "solutions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eUpdate firmware.\u003c/strong\u003e\u0026nbsp;Update EN2* ControlLogix communications modules to mitigated firmware.\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eProperly segment networks.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\u003c/span\u003e\u003c/li\u003e\u003cli\u003e\u003cstrong\u003eImplement detection signatures.\u003c/strong\u003e\u003cspan style=\"background-color: var(--wht);\"\u003e\u0026nbsp;Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\u003c/span\u003e\u003c/li\u003e\u003c/ul\u003e\n\n" } ], "value": "\n * Update firmware.\u00a0Update EN2* ControlLogix communications modules to mitigated firmware.\n * Properly segment networks.\u00a0Given a cyber actor would require network connectivity to the communication module to exploit the vulnerability, organizations should ensure ICS/SCADA networks are properly segmented within the process structure as well as from the Internet and other non-essential networks.\n * Implement detection signatures.\u00a0Use appended Snort signatures to monitor and detect anomalous Common Industrial Protocol (CIP) packets to Rockwell Automation devices.\n\n\n\n\n" } ], "source": { "discovery": "UNKNOWN" }, "title": "Rockwell Automation ControlLogix Communication Modules Vulnerable to Remote Code Execution", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0", "assignerShortName": "Rockwell", "cveId": "CVE-2023-3595", "datePublished": "2023-07-12T12:37:01.939Z", "dateReserved": "2023-07-10T15:34:52.031Z", "dateUpdated": "2024-08-02T07:01:57.031Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-3595\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2023-07-12T13:15:09.880\",\"lastModified\":\"2023-07-25T19:55:53.177\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nWhere this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device.\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]},{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-787\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2f_series_a_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0D4B3185-B776-46C4-B47F-CE48861A422B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2f_series_a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"97AC710F-97B3-47A1-86EC-3148A21F16B2\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2f_series_b_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7242493E-0B2A-4AF3-BF44-15D3D1DB0021\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2f_series_b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FA49358A-F76E-4DEC-994C-B988DE38BF7F\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2f_series_c_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"48F83304-EF89-48A4-AA0E-EBD5AE5E46E5\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2f_series_c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C6E5B08F-BD0C-4B3F-9897-61C945981CC6\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2t_series_a_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"B8E9CEA5-F039-484D-A234-1E3ADA352E32\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2t_series_a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BBB6A3C1-6419-4CDB-B7F5-57F20DA43C5A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2t_series_b_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"ADCF431D-0F13-4037-BBDF-4199B5860CCA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2t_series_b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5E9D2541-B0DB-4925-ACD6-FCC2A028FA4A\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2t_series_c_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E9B8DEC1-3980-49E0-82B1-275FD7870EC9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2t_series_c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"13581B79-89FF-42F0-93C1-CB77582E7303\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2t_series_d_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"88F147B7-96D5-4C52-AE8C-C5A24A103290\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2t_series_d:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F71090C1-36AD-4A1B-92B5-CB391593DF4B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"94271569-D658-4F95-B9A6-2C1DB2647EB2\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2tr_series_a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A4A8E21A-3826-497C-9F3D-6D9091AD7647\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BAEF2D94-6224-4877-9169-E5B0DB3FAA25\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2tr_series_b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8607CD0D-0EE7-41CF-8E00-C0F5C83646A8\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EAB58AD4-EA1F-4106-ADD1-52EF2592B92C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en2tr_series_c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D58BA41B-3859-4489-9C74-730C27B1EFF0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en3tr_series_a_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE90B141-E680-4D15-8BCE-8D58909A3679\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en3tr_series_a:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4824C266-82B1-4B74-AF72-BFCEF0547023\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en3tr_series_b_firmware:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01816E19-DF07-4A48-BC59-4A9918AE94FA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en3tr_series_b:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"14CF3A11-7130-420A-B99E-8FADA7C23484\"}]}]}],\"references\":[{\"url\":\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1140010\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Permissions Required\",\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.