CVE-2024-2426
Vulnerability from cvelistv5
Published
2024-03-25 20:17
Modified
2024-08-12 20:34
Summary
Rockwell Automation - Denial-of-service and Input Validation Vulnerabilities in PowerFlex® 527
Impacted products
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T19:11:53.564Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:rockwellautomation:powerflex_527_ac_drives_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "powerflex_527_ac_drives_firmware",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "lessThan": "*",
                "status": "affected",
                "version": "2.001.0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-2426",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-26T19:57:16.261756Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-12T20:34:49.585Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "PowerFlex\u00ae 527",
          "vendor": "Rockwell Automation ",
          "versions": [
            {
              "status": "affected",
              "version": " v2.001.x \u003c"
            }
          ]
        }
      ],
      "datePublic": "2024-03-21T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-153",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-153 Input Data Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-25T20:18:33.240Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eThere is no fix currently for this vulnerability. Users using the affected software are encouraged to apply risk mitigations and security best practices, where possible.\u003c/p\u003e\u003cul\u003e\u003cli\u003eImplement network segmentation confirming the device is on an isolated network.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um002_-en-e.pdf\"\u003eDisable the web server\u003c/a\u003e, if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later.\u003c/li\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e"
            }
          ],
          "value": "\nThere is no fix currently for this vulnerability. Users using the affected software are encouraged to apply risk mitigations and security best practices, where possible.\n\n  *  Implement network segmentation confirming the device is on an isolated network.\n  *   Disable the web server https://literature.rockwellautomation.com/idc/groups/literature/documents/um/520-um002_-en-e.pdf , if not needed. The web server is disabled by default. Disabling this feature is available in v2.001.x and later.\n  *   Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \n\n"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Rockwell Automation - Denial-of-service and Input Validation Vulnerabilities in PowerFlex\u00ae 527",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-2426",
    "datePublished": "2024-03-25T20:17:22.315Z",
    "dateReserved": "2024-03-13T14:45:10.183Z",
    "dateUpdated": "2024-08-12T20:34:49.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-2426\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-03-25T21:15:47.480\",\"lastModified\":\"2024-03-26T12:55:05.010\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nA denial-of-service vulnerability exists in the Rockwell Automation PowerFlex\u00ae 527 due to improper input validation in the device. If exploited, a disruption in the CIP communication will occur and a manual restart will be required by the user to recover it.\\n\\n\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de denegaci\u00f3n de servicio en Rockwell Automation PowerFlex\u00ae 527 debido a una validaci\u00f3n de entrada incorrecta en el dispositivo. Si se explota, se producir\u00e1 una interrupci\u00f3n en la comunicaci\u00f3n CIP y el usuario deber\u00e1 reiniciar manualmente para recuperarla.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/support/advisory.SD1664.html\",\"source\":\"PSIRT@rockwellautomation.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.