CVE-2018-3679 (GCVE-0-2018-3679)

Vulnerability from cvelistv5 – Published: 2018-09-12 19:00 – Updated: 2024-09-17 02:47
VLAI?
Summary
Escalation of privilege in Reference UI in Intel Data Center Manager SDK 5.0 and before may allow an unauthorized remote unauthenticated user to potentially execute code via administrator privileges.
Severity ?
No CVSS data available.
CWE
  • Escalation of Privilege
Assigner
References
Impacted products
Vendor Product Version
Intel Corporation Intel(R) Data Center Manager SDK Affected: Versions 5.0 and before.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T04:50:30.375Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Intel(R) Data Center Manager SDK",
          "vendor": "Intel Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "Versions 5.0 and before."
            }
          ]
        }
      ],
      "datePublic": "2018-09-11T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "Escalation of privilege in Reference UI in Intel Data Center Manager SDK 5.0 and before may allow an unauthorized remote unauthenticated user to potentially execute code via administrator privileges."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Escalation of Privilege",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-09-12T18:57:01",
        "orgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
        "shortName": "intel"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@intel.com",
          "DATE_PUBLIC": "2018-09-11T00:00:00",
          "ID": "CVE-2018-3679",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Intel(R) Data Center Manager SDK",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Versions 5.0 and before."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Intel Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Escalation of privilege in Reference UI in Intel Data Center Manager SDK 5.0 and before may allow an unauthorized remote unauthenticated user to potentially execute code via administrator privileges."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Escalation of Privilege"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html",
              "refsource": "CONFIRM",
              "url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6dda929c-bb53-4a77-a76d-48e79601a1ce",
    "assignerShortName": "intel",
    "cveId": "CVE-2018-3679",
    "datePublished": "2018-09-12T19:00:00Z",
    "dateReserved": "2017-12-28T00:00:00",
    "dateUpdated": "2024-09-17T02:47:43.265Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"5.0\", \"matchCriteriaId\": \"6194A9E7-EBD6-4AE1-8E3C-BCEF53316705\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Escalation of privilege in Reference UI in Intel Data Center Manager SDK 5.0 and before may allow an unauthorized remote unauthenticated user to potentially execute code via administrator privileges.\"}, {\"lang\": \"es\", \"value\": \"Escalado de privilegios en Reference UI en Intel Data Center Manager SDK en versiones 5.0 y anteriores podr\\u00eda permitir que un usuario remoto no autenticado sin autorizaci\\u00f3n ejecute c\\u00f3digo con privilegios de administrador.\"}]",
      "id": "CVE-2018-3679",
      "lastModified": "2024-11-21T04:05:52.870",
      "metrics": "{\"cvssMetricV30\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"baseScore\": 9.6, \"baseSeverity\": \"CRITICAL\", \"attackVector\": \"ADJACENT_NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:A/AC:L/Au:N/C:C/I:C/A:C\", \"baseScore\": 8.3, \"accessVector\": \"ADJACENT_NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"NONE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 6.5, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2018-09-12T19:29:03.433",
      "references": "[{\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html\", \"source\": \"secure@intel.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "secure@intel.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"NVD-CWE-noinfo\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2018-3679\",\"sourceIdentifier\":\"secure@intel.com\",\"published\":\"2018-09-12T19:29:03.433\",\"lastModified\":\"2024-11-21T04:05:52.870\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Escalation of privilege in Reference UI in Intel Data Center Manager SDK 5.0 and before may allow an unauthorized remote unauthenticated user to potentially execute code via administrator privileges.\"},{\"lang\":\"es\",\"value\":\"Escalado de privilegios en Reference UI en Intel Data Center Manager SDK en versiones 5.0 y anteriores podr\u00eda permitir que un usuario remoto no autenticado sin autorizaci\u00f3n ejecute c\u00f3digo con privilegios de administrador.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.6,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:A/AC:L/Au:N/C:C/I:C/A:C\",\"baseScore\":8.3,\"accessVector\":\"ADJACENT_NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":6.5,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"NVD-CWE-noinfo\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:intel:data_center_manager:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"5.0\",\"matchCriteriaId\":\"6194A9E7-EBD6-4AE1-8E3C-BCEF53316705\"}]}]}],\"references\":[{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html\",\"source\":\"secure@intel.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00143.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…