VLAI?
Summary
Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application.
Severity ?
8.4 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Dell | Integrated Data Protection Appliance |
Affected:
prior to 2.3
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:19:17.626Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Integrated Data Protection Appliance",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "prior to 2.3"
}
]
}
],
"datePublic": "2019-08-08T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-27T20:21:21",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2019-08-08",
"ID": "CVE-2019-3747",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Integrated Data Protection Appliance",
"version": {
"version_data": [
{
"version_value": "prior to 2.3"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.4,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79: Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities",
"refsource": "CONFIRM",
"url": "https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2019-3747",
"datePublished": "2019-09-27T20:21:21.014325Z",
"dateReserved": "2019-01-03T00:00:00",
"dateUpdated": "2024-09-17T00:26:31.837Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5C133A08-973B-43E2-8E0C-9B7AEF467BDD\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.1:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"889D0DDB-7D31-4AE9-972A-AE14CC2A82BF\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.2:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"970D60B9-9DAD-4F1D-BFBE-BB069756011C\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:emc_idpa_dp4400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"70B89DD8-CEE9-4C3D-828D-71139D55A7C5\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:emc_idpa_dp5800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7FEEA32E-07CD-45F0-AB1E-235764A8A094\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:emc_idpa_dp8300:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"8C8B35A8-80BF-443E-992B-6F5B03A9928C\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:emc_idpa_dp8800:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E98F97BD-57F5-4F2E-9573-863503A5B911\"}]}]}]",
"descriptions": "[{\"lang\": \"en\", \"value\": \"Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application.\"}, {\"lang\": \"es\", \"value\": \"Dell EMC Integrated Data Protection Appliance versiones anteriores a 2.3, contienen una vulnerabilidad de tipo cross-site scripting almacenado. Un usuario administrador de ACM malicioso remoto puede explotar esta vulnerabilidad para almacenar c\\u00f3digo HTML o JavaScript malicioso en el campo espec\\u00edfico del add-on Cloud DR. Cuando los usuarios v\\u00edctimas acceden a la p\\u00e1gina por medio de sus navegadores, el c\\u00f3digo malicioso es ejecutado por el navegador en el contexto de la aplicaci\\u00f3n web vulnerable.\"}]",
"id": "CVE-2019-3747",
"lastModified": "2024-11-21T04:42:27.437",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\", \"baseScore\": 4.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"LOW\", \"integrityImpact\": \"LOW\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 2.7}], \"cvssMetricV30\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.0\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H\", \"baseScore\": 8.4, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.7, \"impactScore\": 6.0}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:M/Au:S/C:N/I:P/A:N\", \"baseScore\": 3.5, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"MEDIUM\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"NONE\", \"integrityImpact\": \"PARTIAL\", \"availabilityImpact\": \"NONE\"}, \"baseSeverity\": \"LOW\", \"exploitabilityScore\": 6.8, \"impactScore\": 2.9, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": true}]}",
"published": "2019-09-27T21:15:10.207",
"references": "[{\"url\": \"https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
"sourceIdentifier": "security_alert@emc.com",
"vulnStatus": "Modified",
"weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-79\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2019-3747\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2019-09-27T21:15:10.207\",\"lastModified\":\"2024-11-21T04:42:27.437\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Dell EMC Integrated Data Protection Appliance versions prior to 2.3 contain a stored cross-site scripting vulnerability. A remote malicious ACM admin user may potentially exploit this vulnerability to store malicious HTML or JavaScript code in Cloud DR add-on specific field. When victim users access the page through their browsers, the malicious code gets executed by the web browser in the context of the vulnerable web application.\"},{\"lang\":\"es\",\"value\":\"Dell EMC Integrated Data Protection Appliance versiones anteriores a 2.3, contienen una vulnerabilidad de tipo cross-site scripting almacenado. Un usuario administrador de ACM malicioso remoto puede explotar esta vulnerabilidad para almacenar c\u00f3digo HTML o JavaScript malicioso en el campo espec\u00edfico del add-on Cloud DR. Cuando los usuarios v\u00edctimas acceden a la p\u00e1gina por medio de sus navegadores, el c\u00f3digo malicioso es ejecutado por el navegador en el contexto de la aplicaci\u00f3n web vulnerable.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N\",\"baseScore\":4.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.7,\"impactScore\":2.7}],\"cvssMetricV30\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H\",\"baseScore\":8.4,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.7,\"impactScore\":6.0}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:S/C:N/I:P/A:N\",\"baseScore\":3.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"NONE\"},\"baseSeverity\":\"LOW\",\"exploitabilityScore\":6.8,\"impactScore\":2.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":true}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-79\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5C133A08-973B-43E2-8E0C-9B7AEF467BDD\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"889D0DDB-7D31-4AE9-972A-AE14CC2A82BF\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_integrated_data_protection_appliance_firmware:2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"970D60B9-9DAD-4F1D-BFBE-BB069756011C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:emc_idpa_dp4400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70B89DD8-CEE9-4C3D-828D-71139D55A7C5\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:emc_idpa_dp5800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FEEA32E-07CD-45F0-AB1E-235764A8A094\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:emc_idpa_dp8300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8C8B35A8-80BF-443E-992B-6F5B03A9928C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:emc_idpa_dp8800:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E98F97BD-57F5-4F2E-9573-863503A5B911\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/security/en-us/details/536363/DSA-2019-112-Dell-EMC-Integrated-Data-Protection-Appliance-Multiple-Vulnerabilities\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}"
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…