cve-2020-5353
Vulnerability from cvelistv5
Published
2021-07-29 15:55
Modified
2024-09-17 00:27
Summary
The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an 'admin' home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system.
Impacted products
Vendor Product Version
Dell Isilon OneFS Version: unspecified   < All supported
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:23.439Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.emc.com/kb/542721"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Isilon OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "All supported",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-04-09T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an \u0027admin\u0027 home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276: Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-29T15:55:15",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.emc.com/kb/542721"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-04-09",
          "ID": "CVE-2020-5353",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Isilon OneFS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "All supported"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an \u0027admin\u0027 home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-276: Incorrect Default Permissions"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.emc.com/kb/542721",
              "refsource": "MISC",
              "url": "https://support.emc.com/kb/542721"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5353",
    "datePublished": "2021-07-29T15:55:15.791310Z",
    "dateReserved": "2020-01-03T00:00:00",
    "dateUpdated": "2024-09-17T00:27:01.594Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:dell:emc_isilon_onefs:*:*:*:*:*:*:*:*\", \"versionEndIncluding\": \"8.2.2\", \"matchCriteriaId\": \"1041FD80-0BC7-4C1E-B310-B17EB68668D6\"}, {\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:emc_powerscale_onefs:9.0.0:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"5422D856-00B1-47FA-8D62-9B464A43BAC9\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an \u0027admin\u0027 home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system.\"}, {\"lang\": \"es\", \"value\": \"Dell Isilon OneFS versiones 8.2.2 y anteriores y Dell EMC PowerScale OneFS versiones 9.0.0, una configuraci\\u00f3n predeterminada para Network File System (NFS) permite el acceso a un directorio de inicio \\\"admin\\\". Un atacante puede aprovechar un Unique Identifier (UID) falsificado a trav\\u00e9s de NFS para reescribir archivos confidenciales y conseguir acceso administrativo al sistema\"}]",
      "id": "CVE-2020-5353",
      "lastModified": "2024-11-21T05:33:58.147",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 8.8, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 2.8, \"impactScore\": 5.9}], \"cvssMetricV2\": [{\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"2.0\", \"vectorString\": \"AV:N/AC:L/Au:S/C:C/I:C/A:C\", \"baseScore\": 9.0, \"accessVector\": \"NETWORK\", \"accessComplexity\": \"LOW\", \"authentication\": \"SINGLE\", \"confidentialityImpact\": \"COMPLETE\", \"integrityImpact\": \"COMPLETE\", \"availabilityImpact\": \"COMPLETE\"}, \"baseSeverity\": \"HIGH\", \"exploitabilityScore\": 8.0, \"impactScore\": 10.0, \"acInsufInfo\": false, \"obtainAllPrivilege\": false, \"obtainUserPrivilege\": false, \"obtainOtherPrivilege\": false, \"userInteractionRequired\": false}]}",
      "published": "2021-07-29T16:15:08.610",
      "references": "[{\"url\": \"https://support.emc.com/kb/542721\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}, {\"url\": \"https://support.emc.com/kb/542721\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Patch\", \"Vendor Advisory\"]}]",
      "sourceIdentifier": "security_alert@emc.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-276\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-276\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2020-5353\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2021-07-29T16:15:08.610\",\"lastModified\":\"2024-11-21T05:33:58.147\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Dell Isilon OneFS versions 8.2.2 and earlier and Dell EMC PowerScale OneFS version 9.0.0 default configuration for Network File System (NFS) allows access to an \u0027admin\u0027 home directory. An attacker may leverage a spoofed Unique Identifier (UID) over NFS to rewrite sensitive files to gain administrative access to the system.\"},{\"lang\":\"es\",\"value\":\"Dell Isilon OneFS versiones 8.2.2 y anteriores y Dell EMC PowerScale OneFS versiones 9.0.0, una configuraci\u00f3n predeterminada para Network File System (NFS) permite el acceso a un directorio de inicio \\\"admin\\\". Un atacante puede aprovechar un Unique Identifier (UID) falsificado a trav\u00e9s de NFS para reescribir archivos confidenciales y conseguir acceso administrativo al sistema\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:C/I:C/A:C\",\"baseScore\":9.0,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"COMPLETE\",\"integrityImpact\":\"COMPLETE\",\"availabilityImpact\":\"COMPLETE\"},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.0,\"impactScore\":10.0,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-276\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:dell:emc_isilon_onefs:*:*:*:*:*:*:*:*\",\"versionEndIncluding\":\"8.2.2\",\"matchCriteriaId\":\"1041FD80-0BC7-4C1E-B310-B17EB68668D6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:emc_powerscale_onefs:9.0.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"5422D856-00B1-47FA-8D62-9B464A43BAC9\"}]}]}],\"references\":[{\"url\":\"https://support.emc.com/kb/542721\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Patch\",\"Vendor Advisory\"]},{\"url\":\"https://support.emc.com/kb/542721\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Patch\",\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.