cve-2021-35533
Vulnerability from cvelistv5
Published
2021-11-26 16:37
Modified
2024-09-16 21:02
Severity ?
EPSS score ?
Summary
Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Hitachi Energy | RTU500 series |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-04T00:40:47.218Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_refsource_CONFIRM", "x_transferred" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "product": "RTU500 series", "vendor": "Hitachi Energy", "versions": [ { "lessThanOrEqual": "12.0.*", "status": "affected", "version": "CMU Firmware version 12.0", "versionType": "custom" }, { "lessThanOrEqual": "12.2.*", "status": "affected", "version": "CMU Firmware version 12.2", "versionType": "custom" }, { "lessThanOrEqual": "12.4.*", "status": "affected", "version": "CMU Firmware version 12.4", "versionType": "custom" } ] } ], "datePublic": "2021-11-17T00:00:00", "descriptions": [ { "lang": "en", "value": "Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions)." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-20", "description": "CWE-20 Improper Input Validation", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2021-11-26T16:37:27", "orgId": "e383dce4-0c27-4495-91c4-0db157728d17", "shortName": "Hitachi Energy" }, "references": [ { "tags": [ "x_refsource_CONFIRM" ], "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ], "solutions": [ { "lang": "en", "value": "- Disable BCI IEC 60870-5-104 function by configuration if it is not used.\n- Update to RTU500 series CMU Firmware version 12.6.5.0 or later (e.g., RTU500 CMU Firmware version 12.7.* or CMU Firmware version 13.2.* or later)." } ], "source": { "discovery": "INTERNAL" }, "title": "Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series", "x_generator": { "engine": "Vulnogram 0.0.9" }, "x_legacyV4Record": { "CVE_data_meta": { "ASSIGNER": "cybersecurity@hitachienergy.com", "DATE_PUBLIC": "2021-11-17T14:00:00.000Z", "ID": "CVE-2021-35533", "STATE": "PUBLIC", "TITLE": "Specially Crafted IEC 60870-5-104 Packet Vulnerability in RTU500 series" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "RTU500 series", "version": { "version_data": [ { "version_affected": "\u003c=", "version_name": "CMU Firmware version 12.0", "version_value": "12.0.*" }, { "version_affected": "\u003c=", "version_name": "CMU Firmware version 12.2", "version_value": "12.2.*" }, { "version_affected": "\u003c=", "version_name": "CMU Firmware version 12.4", "version_value": "12.4.*" } ] } } ] }, "vendor_name": "Hitachi Energy" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions)." } ] }, "generator": { "engine": "Vulnogram 0.0.9" }, "impact": { "cvss": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-20 Improper Input Validation" } ] } ] }, "references": { "reference_data": [ { "name": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch", "refsource": "CONFIRM", "url": "https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch" } ] }, "solution": [ { "lang": "en", "value": "- Disable BCI IEC 60870-5-104 function by configuration if it is not used.\n- Update to RTU500 series CMU Firmware version 12.6.5.0 or later (e.g., RTU500 CMU Firmware version 12.7.* or CMU Firmware version 13.2.* or later)." } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en" } ] } } }, "cveMetadata": { "assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17", "assignerShortName": "Hitachi Energy", "cveId": "CVE-2021-35533", "datePublished": "2021-11-26T16:37:27.683297Z", "dateReserved": "2021-06-28T00:00:00", "dateUpdated": "2024-09-16T21:02:16.277Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2021-35533\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2021-11-26T17:15:07.743\",\"lastModified\":\"2023-05-16T21:04:23.433\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500 series allows an attacker to cause the receiving RTU500 CMU of which the BCI is enabled to reboot when receiving a specially crafted message. By default, BCI IEC 60870-5-104 function is disabled (not configured). This issue affects: Hitachi Energy RTU500 series CMU Firmware version 12.0.* (all versions); CMU Firmware version 12.2.* (all versions); CMU Firmware version 12.4.* (all versions).\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de comprobaci\u00f3n de entrada inapropiada en el analizador de APDU en la funci\u00f3n IEC 60870-5-104 de la interfaz de comunicaci\u00f3n bidireccional (BCI) de la serie RTU500 de Hitachi Energy permite a un atacante causar el reinicio de la CMU RTU500 receptora en la que est\u00e1 habilitado el BCI cuando recibe un mensaje especialmente dise\u00f1ado. Por defecto, la funci\u00f3n BCI IEC 60870-5-104 est\u00e1 deshabilitada (no configurada). Este problema afecta a: Firmware de la CMU de la serie Hitachi Energy RTU500, versi\u00f3n 12.0.* (todas las versiones); Firmware de la CMU, versi\u00f3n 12.2.* (todas las versiones); Firmware de la CMU, versi\u00f3n 12.4.* (todas las versiones)\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":3.6}],\"cvssMetricV2\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:M/Au:N/C:N/I:N/A:C\",\"accessVector\":\"NETWORK\",\"accessComplexity\":\"MEDIUM\",\"authentication\":\"NONE\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"COMPLETE\",\"baseScore\":7.1},\"baseSeverity\":\"HIGH\",\"exploitabilityScore\":8.6,\"impactScore\":6.9,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]},{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hitachienergy:rtu500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"DE94252D-03EE-451B-8322-B4DBC790C6E9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:12.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9BA3F33A-8787-4128-A790-685BCB272A82\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:12.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"FCD4343D-4B6E-4D6A-A2F3-EFA5CFE4290D\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:hitachienergy:rtu500_firmware:12.4:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"9CCC7155-16F2-4E60-ABCB-0E6FF71CEC67\"}]}]}],\"references\":[{\"url\":\"https://search.abb.com/library/Download.aspx?DocumentID=8DBD000063\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch\",\"source\":\"cybersecurity@hitachienergy.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.