cve-2023-29063
Vulnerability from cvelistv5
Published
2023-11-28 20:34
Modified
2024-08-02 14:00
Severity ?
EPSS score ?
Summary
Lack of DMA Access Protections
References
Impacted products
▼ | Vendor | Product |
---|---|---|
Becton, Dickinson and Company (BD) | FACSChorus |
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T14:00:14.934Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-facschorus-software" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "platforms": [ "Windows", "64 bit" ], "product": "FACSChorus", "vendor": "Becton, Dickinson and Company (BD)", "versions": [ { "lessThanOrEqual": "5.1", "status": "affected", "version": "5.0", "versionType": "custom" }, { "lessThanOrEqual": "3.1", "status": "affected", "version": "3.0", "versionType": "custom" } ] } ], "datePublic": "2023-11-28T14:24:00.000Z", "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive information such as a BitLocker encryption key from a dump of the workstation RAM during startup." } ], "value": "The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive information such as a BitLocker encryption key from a dump of the workstation RAM during startup." } ], "impacts": [ { "capecId": "CAPEC-121", "descriptions": [ { "lang": "en", "value": "CAPEC-121 Exploit Non-Production Interfaces" } ] } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "NONE", "baseScore": 2.4, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-1299", "description": "CWE-1299 Missing Protection Mechanism for Alternate Hardware Interface", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-11-28T20:34:59.290Z", "orgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18", "shortName": "BD" }, "references": [ { "url": "https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-facschorus-software" } ], "source": { "discovery": "UNKNOWN" }, "title": "Lack of DMA Access Protections", "workarounds": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\n\nVulnerabilities associated with the BD FACSChorus software and workstations will be addressed in an upcoming release. This bulletin will be updated when more information is available. Please check periodically for updates. Additionally, BD recommends the following mitigations and compensating controls to reduce risk associated with these vulnerabilities. The following recommendations apply to all vulnerabilities listed in this bulletin:\u003cbr\u003e\u003cul\u003e\u003cli\u003eEnsure physical access controls are in place and only authorized end-users have access to the BD FACSChorus Software and respective workstation.\u003c/li\u003e\u003cli\u003eIf the BD FACSChorus workstation is connected to the local network, ensure industry standard network security policies and procedures are followed.\u003c/li\u003e\u003cli\u003eAdministrative access to the FACSChorus software and workstation should be strictly controlled by the customer in collaboration with their local IT security policy.\u003c/li\u003e\u003c/ul\u003e" } ], "value": "\n\n\nVulnerabilities associated with the BD FACSChorus software and workstations will be addressed in an upcoming release. This bulletin will be updated when more information is available. Please check periodically for updates. Additionally, BD recommends the following mitigations and compensating controls to reduce risk associated with these vulnerabilities. The following recommendations apply to all vulnerabilities listed in this bulletin:\n * Ensure physical access controls are in place and only authorized end-users have access to the BD FACSChorus Software and respective workstation.\n * If the BD FACSChorus workstation is connected to the local network, ensure industry standard network security policies and procedures are followed.\n * Administrative access to the FACSChorus software and workstation should be strictly controlled by the customer in collaboration with their local IT security policy.\n\n\n" } ], "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "2325d071-eabf-4b7b-a4ea-0819b6629a18", "assignerShortName": "BD", "cveId": "CVE-2023-29063", "datePublished": "2023-11-28T20:34:59.290Z", "dateReserved": "2023-03-30T21:10:17.526Z", "dateUpdated": "2024-08-02T14:00:14.934Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-29063\",\"sourceIdentifier\":\"cybersecurity@bd.com\",\"published\":\"2023-11-28T21:15:07.613\",\"lastModified\":\"2023-12-05T14:45:30.123\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive information such as a BitLocker encryption key from a dump of the workstation RAM during startup.\"},{\"lang\":\"es\",\"value\":\"La estaci\u00f3n de trabajo FACSChorus no impide el acceso f\u00edsico a sus ranuras PCI express (PCIe), lo que podr\u00eda permitir que un actor de amenazas inserte una tarjeta PCI dise\u00f1ada para la captura de memoria. Luego, un actor de amenazas puede aislar informaci\u00f3n confidencial, como una clave de cifrado BitLocker, de un volcado de la RAM de la estaci\u00f3n de trabajo durante el inicio.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.4,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":0.9,\"impactScore\":1.4},{\"source\":\"cybersecurity@bd.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.4,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":0.9,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-306\"}]},{\"source\":\"cybersecurity@bd.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1299\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bd:facschorus:5.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4D5E0D4F-559B-414E-A627-0BA0937BD7F1\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bd:facschorus:5.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"57F63FB2-2AE2-4B5F-8B49-4A0A4549CF3E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hp:hp_z2_tower_g9:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"54279DE4-A2A4-4AA6-A05F-931094446F16\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bd:facschorus:3.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2785D17E-800C-4772-A131-5737E9446C01\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:bd:facschorus:3.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"30FD1DE4-982F-4D14-BB8A-478F8430BC63\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:hp:hp_z2_tower_g5:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7E9BA28D-9C14-435A-9786-222BE58A9258\"}]}]}],\"references\":[{\"url\":\"https://www.bd.com/en-us/about-bd/cybersecurity/bulletin/bd-facschorus-software\",\"source\":\"cybersecurity@bd.com\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.