cve-2023-36556
Vulnerability from cvelistv5
Published
2023-10-10 16:49
Modified
2024-10-22 20:57
Summary
An incorrect authorization vulnerability [CWE-863] in FortiMail webmail version 7.2.0 through 7.2.2, version 7.0.0 through 7.0.5 and below 6.4.7 allows an authenticated attacker to login on other users accounts from the same web domain via crafted HTTP or HTTPs requests.
Impacted products
FortinetFortiMail
Show details on NVD website


{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T16:52:53.483Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "https://fortiguard.com/psirt/FG-IR-23-202",
            "tags": [
              "x_transferred"
            ],
            "url": "https://fortiguard.com/psirt/FG-IR-23-202"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-36556",
                "options": [
                  {
                    "Exploitation": "None"
                  },
                  {
                    "Automatable": "No"
                  },
                  {
                    "Technical Impact": "Total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-22T20:57:32.689334Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-22T20:57:57.262Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "FortiMail",
          "vendor": "Fortinet",
          "versions": [
            {
              "lessThanOrEqual": "7.2.2",
              "status": "affected",
              "version": "7.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "7.0.5",
              "status": "affected",
              "version": "7.0.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.4.7",
              "status": "affected",
              "version": "6.4.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.2.9",
              "status": "affected",
              "version": "6.2.0",
              "versionType": "semver"
            },
            {
              "lessThanOrEqual": "6.0.12",
              "status": "affected",
              "version": "6.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "An incorrect authorization vulnerability [CWE-863] in FortiMail webmail version 7.2.0 through 7.2.2, version 7.0.0 through 7.0.5 and below 6.4.7 allows an authenticated attacker to login on other users accounts from the same web domain via crafted HTTP or HTTPs requests."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.6,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:F/RL:X/RC:C",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-863",
              "description": "Escalation of privilege",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-10-10T16:49:50.906Z",
        "orgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
        "shortName": "fortinet"
      },
      "references": [
        {
          "name": "https://fortiguard.com/psirt/FG-IR-23-202",
          "url": "https://fortiguard.com/psirt/FG-IR-23-202"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please upgrade to FortiMail version 7.4.0 or above Please upgrade to FortiMail version 7.2.3 or above Please upgrade to FortiMail version 7.0.6 or above Please upgrade to FortiMail version 6.4.8 or above "
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "6abe59d8-c742-4dff-8ce8-9b0ca1073da8",
    "assignerShortName": "fortinet",
    "cveId": "CVE-2023-36556",
    "datePublished": "2023-10-10T16:49:50.906Z",
    "dateReserved": "2023-06-23T14:57:30.033Z",
    "dateUpdated": "2024-10-22T20:57:57.262Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-36556\",\"sourceIdentifier\":\"psirt@fortinet.com\",\"published\":\"2023-10-10T17:15:12.140\",\"lastModified\":\"2023-11-07T04:16:37.820\",\"vulnStatus\":\"Modified\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"An incorrect authorization vulnerability [CWE-863] in FortiMail webmail version 7.2.0 through 7.2.2, version 7.0.0 through 7.0.5 and below 6.4.7 allows an authenticated attacker to login on other users accounts from the same web domain via crafted HTTP or HTTPs requests.\"},{\"lang\":\"es\",\"value\":\"Una vulnerabilidad de autorizaci\u00f3n incorrecta [CWE-863] en el correo web FortiMail versi\u00f3n 7.2.0 a 7.2.2, versi\u00f3n 7.0.0 a 7.0.5 e inferior a 6.4.7 permite a un atacante autenticado iniciar sesi\u00f3n en cuentas de otros usuarios desde el mismo dominio web a trav\u00e9s de solicitudes HTTP o HTTPs manipuladas.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9},{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.8,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]},{\"source\":\"psirt@fortinet.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-863\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.0.0\",\"versionEndIncluding\":\"6.0.12\",\"matchCriteriaId\":\"01F784BF-4F89-4938-9150-F911E3EB6CD0\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.2.0\",\"versionEndIncluding\":\"6.2.9\",\"matchCriteriaId\":\"AEDC7EE8-084C-4F9E-A510-E283FCDF9832\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"6.4.0\",\"versionEndIncluding\":\"6.4.7\",\"matchCriteriaId\":\"7D25AB0A-3B0C-40B5-8D7D-78DA7567F6F6\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"7.0.0\",\"versionEndIncluding\":\"7.0.5\",\"matchCriteriaId\":\"3A56C791-6437-4BA5-922C-3352FF5D8431\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:7.2.0:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"BD3A9BF6-5A5E-4D25-BDB4-CD9AA9DA8580\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:7.2.1:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"22B39FED-3BE4-4362-A071-93A235CE6089\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:fortinet:fortimail:7.2.2:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"235B3CB6-E9A3-4849-AF87-954693BA2EDE\"}]}]}],\"references\":[{\"url\":\"https://fortiguard.com/psirt/FG-IR-23-202\",\"source\":\"psirt@fortinet.com\",\"tags\":[\"Vendor Advisory\"]}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.