cve-2023-4089
Vulnerability from cvelistv5
Published
2023-10-17 06:00
Modified
2024-08-02 07:17
Severity ?
EPSS score ?
Summary
WAGO: Multiple products vulnerable to local file inclusion
References
▼ | URL | Tags | |
---|---|---|---|
info@cert.vde.com | https://cert.vde.com/en/advisories/VDE-2023-046/ | Third Party Advisory |
Impacted products
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-02T07:17:11.728Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert.vde.com/en/advisories/VDE-2023-046/" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Compact Controller CC100", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW19", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Edge Controller", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW18", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC100", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW16", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "PFC200", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW16", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Touch Panel 600 Advanced Line", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW16", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Touch Panel 600 Marine Line", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW16", "versionType": "semver" } ] }, { "defaultStatus": "unaffected", "product": "Touch Panel 600 Standard Line", "vendor": "WAGO", "versions": [ { "lessThanOrEqual": "FW26", "status": "affected", "version": "FW16", "versionType": "semver" } ] } ], "credits": [ { "lang": "en", "type": "reporter", "user": "00000000-0000-4000-9000-000000000000", "value": "Floris Hendriks and Jeroen Wijenbergh from Radboud University" } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected." } ], "value": "On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected." } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 2.7, "baseSeverity": "LOW", "confidentialityImpact": "LOW", "integrityImpact": "NONE", "privilegesRequired": "HIGH", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-610", "description": "CWE-610 Externally Controlled Reference to a Resource in Another Sphere", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2023-10-17T06:00:28.908Z", "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "shortName": "CERTVDE" }, "references": [ { "url": "https://cert.vde.com/en/advisories/VDE-2023-046/" } ], "source": { "advisory": "VDE-2023-046", "defect": [ "CERT@VDE#64532" ], "discovery": "EXTERNAL" }, "title": "WAGO: Multiple products vulnerable to local file inclusion", "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c", "assignerShortName": "CERTVDE", "cveId": "CVE-2023-4089", "datePublished": "2023-10-17T06:00:28.908Z", "dateReserved": "2023-08-02T07:20:35.600Z", "dateUpdated": "2024-08-02T07:17:11.728Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-4089\",\"sourceIdentifier\":\"info@cert.vde.com\",\"published\":\"2023-10-17T07:15:10.090\",\"lastModified\":\"2023-10-24T18:00:38.507\",\"vulnStatus\":\"Analyzed\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"On affected Wago products an remote attacker with administrative privileges can access files to which he has already access to through an undocumented local file inclusion. This access is logged in a different log file than expected.\"},{\"lang\":\"es\",\"value\":\"En los productos Wago afectados, un atacante remoto con privilegios administrativos puede acceder a archivos a los que ya tiene acceso a trav\u00e9s de una inclusi\u00f3n de archivo local no documentada. Este acceso se registra en un archivo de registro diferente al esperado.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\",\"baseScore\":2.7,\"baseSeverity\":\"LOW\"},\"exploitabilityScore\":1.2,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"info@cert.vde.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-610\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:compact_controller_100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"532907AF-7E4A-4065-A799-753FC3313D6C\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:compact_controller_100_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"19\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"A495C583-8184-45A5-81E9-E621A58B7E51\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:edge_controller:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2DFC57C8-6AF4-4771-B0A0-744137FBFECF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:edge_controller_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"18\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"85625EA0-E44C-4A48-BA05-5D506CFDB678\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8F636354-95A2-4B36-9666-1FA57F185432\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc100_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"9E5D5929-675F-493C-B3AF-70C7C79D3CEB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"688A3248-7EAA-499D-A47C-A4D4900CDBD1\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"4F73AE30-E917-433E-BB67-CA383FCDDAFC\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_advanced:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A8221861-7455-41D5-B310-6AEA822B46CF\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_advanced_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"2DA3F602-1720-4B4B-A834-BD620D9B1F54\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_marine:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"83DEFFBC-934D-43BE-92AE-25F8EE8C1E0A\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_marine_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"A1FED163-F917-4CBC-83DA-D4D751C9121B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:wago:touch_panel_600_standard:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E6D7A44C-2D95-4F69-A7DB-435B0A6F9F03\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:wago:touch_panel_600_standard_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"16\",\"versionEndIncluding\":\"26\",\"matchCriteriaId\":\"98F0C3C2-DE57-4134-AC3C-3D000A33528A\"}]}]}],\"references\":[{\"url\":\"https://cert.vde.com/en/advisories/VDE-2023-046/\",\"source\":\"info@cert.vde.com\",\"tags\":[\"Third Party Advisory\"]}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.