cve-2023-6408
Vulnerability from cvelistv5
Published
2024-02-14 16:52
Modified
2024-08-02 08:28
Severity ?
EPSS score ?
Summary
CWE-924: Improper Enforcement of Message Integrity During Transmission in a
Communication Channel vulnerability exists that could cause a denial of service and loss of
confidentiality, integrity of controllers when conducting a Man in the Middle attack.
References
Impacted products
{ "containers": { "adp": [ { "affected": [ { "cpes": [ "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep581020h_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep582020h_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040h_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep582040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep583020_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep583040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep584020_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep584040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmep585040_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "modicon_m580_bmep585040_firmware", "vendor": "schneider-electric", "versions": [ { "lessThan": "4.20", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp341000h_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342000_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102cl_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420102_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2010_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342010_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342020h_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302cl_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp3420302h_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmx_p34-2030_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m340_bmxp342030h_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "modicon_m340_bmxp342030h_firmware", "vendor": "schneider-electric", "versions": [ { "lessThan": "3.60", "status": "affected", "version": "0", "versionType": "custom" } ] }, { "cpes": [ "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh582040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh584040s_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040c_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040_firmware:-:*:*:*:*:*:*:*", "cpe:2.3:o:schneider-electric:modicon_m580_bmeh586040s_firmware:-:*:*:*:*:*:*:*" ], "defaultStatus": "unknown", "product": "modicon_m580_bmeh586040s_firmware", "vendor": "schneider-electric", "versions": [ { "lessThan": "*", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "metrics": [ { "other": { "content": { "id": "CVE-2023-6408", "options": [ { "Exploitation": "none" }, { "Automatable": "no" }, { "Technical Impact": "total" } ], "role": "CISA Coordinator", "timestamp": "2024-07-17T19:15:41.696437Z", "version": "2.0.3" }, "type": "ssvc" } } ], "providerMetadata": { "dateUpdated": "2024-07-17T19:36:47.656Z", "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0", "shortName": "CISA-ADP" }, "title": "CISA ADP Vulnrichment" }, { "providerMetadata": { "dateUpdated": "2024-08-02T08:28:21.776Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unaffected", "product": "Modicon M340 CPU (part numbers BMXP34*)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Versions prior to sv3.60" } ] }, { "defaultStatus": "unaffected", "product": "Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Versions prior to sv4.20" } ] }, { "defaultStatus": "unaffected", "product": "Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S)", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "All Versions" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Control Expert", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Versions prior to v16.0" } ] }, { "defaultStatus": "unaffected", "product": "EcoStruxure Process Expert", "vendor": "Schneider Electric", "versions": [ { "status": "affected", "version": "Versions prior to v2023" } ] } ], "descriptions": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n" } ], "value": "\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\n\n" } ], "metrics": [ { "cvssV3_1": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "format": "CVSS", "scenarios": [ { "lang": "en", "value": "GENERAL" } ] } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-924", "description": "CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-02-14T16:52:24.805Z", "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "shortName": "schneider" }, "references": [ { "url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf" } ], "source": { "discovery": "UNKNOWN" }, "x_generator": { "engine": "Vulnogram 0.1.0-dev" } } }, "cveMetadata": { "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb", "assignerShortName": "schneider", "cveId": "CVE-2023-6408", "datePublished": "2024-02-14T16:52:24.805Z", "dateReserved": "2023-11-30T09:52:30.945Z", "dateUpdated": "2024-08-02T08:28:21.776Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2023-6408\",\"sourceIdentifier\":\"cybersecurity@se.com\",\"published\":\"2024-02-14T17:15:11.057\",\"lastModified\":\"2024-02-14T18:04:50.373\",\"vulnStatus\":\"Awaiting Analysis\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nCWE-924: Improper Enforcement of Message Integrity During Transmission in a\\nCommunication Channel vulnerability exists that could cause a denial of service and loss of\\nconfidentiality, integrity of controllers when conducting a Man in the Middle attack.\\n\\n\"},{\"lang\":\"es\",\"value\":\"CWE-924: Existe una vulnerabilidad en la aplicaci\u00f3n inadecuada de la integridad de los mensajes durante la transmisi\u00f3n en un canal de comunicaci\u00f3n que podr\u00eda causar una denegaci\u00f3n de servicio y p\u00e9rdida de confidencialidad e integridad de los controladores al realizar un ataque Man in the Middle.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\",\"baseScore\":8.1,\"baseSeverity\":\"HIGH\"},\"exploitabilityScore\":2.2,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@se.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-924\"}]}],\"references\":[{\"url\":\"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf\",\"source\":\"cybersecurity@se.com\"}]}}" } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.