CVE-2024-0400 (GCVE-0-2024-0400)
Vulnerability from cvelistv5 – Published: 2024-03-27 02:03 – Updated: 2025-10-16 08:07
VLAI?
Summary
SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.
Severity ?
7.5 (High)
CWE
- CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hitachi Energy | MACH SCM |
Affected:
4.0 , ≤ 4.38
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:04:49.537Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi_energy:mach_scm:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "mach_scm",
"vendor": "hitachi_energy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-0400",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-06T18:54:08.600663Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-06T19:00:32.693Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "MACH SCM",
"vendor": "Hitachi Energy",
"versions": [
{
"lessThanOrEqual": "4.38",
"status": "affected",
"version": "4.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability."
}
],
"value": "SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability."
}
],
"impacts": [
{
"capecId": "CAPEC-551",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-551 Modify Existing Service"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-16T08:07:33.107Z",
"orgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"shortName": "Hitachi Energy"
},
"references": [
{
"url": "https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "e383dce4-0c27-4495-91c4-0db157728d17",
"assignerShortName": "Hitachi Energy",
"cveId": "CVE-2024-0400",
"datePublished": "2024-03-27T02:03:57.253Z",
"dateReserved": "2024-01-10T15:23:18.527Z",
"dateUpdated": "2025-10-16T08:07:33.107Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"fkie_nvd": {
"descriptions": "[{\"lang\": \"en\", \"value\": \"SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.\"}, {\"lang\": \"es\", \"value\": \"El software SCM es una aplicaci\\u00f3n cliente y servidor. Un cliente del administrador del sistema autenticado puede ejecutar consultas LINQ en el servidor SCM para un filtrado personalizado. Un cliente malicioso autenticado puede enviar un c\\u00f3digo especialmente dise\\u00f1ado para omitir la validaci\\u00f3n y ejecutar c\\u00f3digo arbitrario (RCE) en el servidor SCM de forma remota. Los clientes malintencionados pueden ejecutar cualquier comando utilizando esta vulnerabilidad RCE.\"}]",
"id": "CVE-2024-0400",
"lastModified": "2024-11-21T08:46:30.080",
"metrics": "{\"cvssMetricV31\": [{\"source\": \"cybersecurity@hitachienergy.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"baseScore\": 7.5, \"baseSeverity\": \"HIGH\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"HIGH\", \"availabilityImpact\": \"HIGH\"}, \"exploitabilityScore\": 1.6, \"impactScore\": 5.9}]}",
"published": "2024-03-27T03:15:10.697",
"references": "[{\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"source\": \"cybersecurity@hitachienergy.com\"}, {\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": "[{\"source\": \"cybersecurity@hitachienergy.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-94\"}]}]"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2024-0400\",\"sourceIdentifier\":\"cybersecurity@hitachienergy.com\",\"published\":\"2024-03-27T03:15:10.697\",\"lastModified\":\"2024-11-21T08:46:30.080\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.\"},{\"lang\":\"es\",\"value\":\"El software SCM es una aplicaci\u00f3n cliente y servidor. Un cliente del administrador del sistema autenticado puede ejecutar consultas LINQ en el servidor SCM para un filtrado personalizado. Un cliente malicioso autenticado puede enviar un c\u00f3digo especialmente dise\u00f1ado para omitir la validaci\u00f3n y ejecutar c\u00f3digo arbitrario (RCE) en el servidor SCM de forma remota. Los clientes malintencionados pueden ejecutar cualquier comando utilizando esta vulnerabilidad RCE.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.5,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.6,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"cybersecurity@hitachienergy.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-94\"}]}],\"references\":[{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\",\"source\":\"cybersecurity@hitachienergy.com\"},{\"url\":\"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:04:49.537Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-0400\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-08-06T18:54:08.600663Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:hitachi_energy:mach_scm:*:*:*:*:*:*:*:*\"], \"vendor\": \"hitachi_energy\", \"product\": \"mach_scm\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"4.38\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-08-06T18:59:47.077Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-551\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-551 Modify Existing Service\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"HIGH\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hitachi Energy\", \"product\": \"MACH SCM\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"4.38\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://publisher.hitachienergy.com/preview?DocumentId=8DBD000189\u0026languageCode=en\u0026Preview=true\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"SCM Software is a client and server application. An Authenticated System manager client can execute LINQ query in the SCM server, for customized filtering. An Authenticated malicious client can send a specially crafted code to skip the validation and execute arbitrary code (RCE) on the SCM Server remotely. Malicious clients can execute any command by using this RCE vulnerability.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-94\", \"description\": \"CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"e383dce4-0c27-4495-91c4-0db157728d17\", \"shortName\": \"Hitachi Energy\", \"dateUpdated\": \"2025-10-16T08:07:33.107Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-0400\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-16T08:07:33.107Z\", \"dateReserved\": \"2024-01-10T15:23:18.527Z\", \"assignerOrgId\": \"e383dce4-0c27-4495-91c4-0db157728d17\", \"datePublished\": \"2024-03-27T02:03:57.253Z\", \"assignerShortName\": \"Hitachi Energy\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…