Action not permitted
Modal body text goes here.
Modal Title
Modal Body
cve-2024-23813
Vulnerability from cvelistv5
Published
2024-02-13 09:00
Modified
2024-08-01 23:13
Severity ?
EPSS score ?
Summary
A vulnerability has been identified in Polarion ALM (All versions < V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
▼ | Siemens | Polarion ALM |
Version: 0 < V2404.0 |
|
{ "containers": { "adp": [ { "providerMetadata": { "dateUpdated": "2024-08-01T23:13:08.420Z", "orgId": "af854a3a-2127-422b-91ae-364da2661108", "shortName": "CVE" }, "references": [ { "tags": [ "x_transferred" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" } ], "title": "CVE Program Container" } ], "cna": { "affected": [ { "defaultStatus": "unknown", "product": "Polarion ALM", "vendor": "Siemens", "versions": [ { "lessThan": "V2404.0", "status": "affected", "version": "0", "versionType": "custom" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Polarion ALM (All versions \u003c V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code." } ], "metrics": [ { "cvssV3_1": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } } ], "problemTypes": [ { "descriptions": [ { "cweId": "CWE-287", "description": "CWE-287: Improper Authentication", "lang": "en", "type": "CWE" } ] } ], "providerMetadata": { "dateUpdated": "2024-05-15T07:23:55.656Z", "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "shortName": "siemens" }, "references": [ { "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" } ] } }, "cveMetadata": { "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77", "assignerShortName": "siemens", "cveId": "CVE-2024-23813", "datePublished": "2024-02-13T09:00:25.915Z", "dateReserved": "2024-01-22T17:44:56.763Z", "dateUpdated": "2024-08-01T23:13:08.420Z", "state": "PUBLISHED" }, "dataType": "CVE_RECORD", "dataVersion": "5.1", "vulnerability-lookup:meta": { "nvd": "{\"cve\":{\"id\":\"CVE-2024-23813\",\"sourceIdentifier\":\"productcert@siemens.com\",\"published\":\"2024-02-13T09:15:50.140\",\"lastModified\":\"2024-11-21T08:58:28.663\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been identified in Polarion ALM (All versions \u003c V2404.0). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.\"},{\"lang\":\"es\",\"value\":\"Se ha identificado una vulnerabilidad en Polarion ALM (todas las versiones). Los endpoints de la API REST del conector de puertas del producto afectado carecen de la autenticaci\u00f3n adecuada. Un atacante no autenticado podr\u00eda acceder a los endpoints y potencialmente ejecutar c\u00f3digo.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":7.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":3.9,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"productcert@siemens.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-287\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:siemens:polarion_alm:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2404.0\",\"matchCriteriaId\":\"00E023E4-0221-4342-8EE3-9D6CA296BE82\"}]}]}],\"references\":[{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-871717.html\",\"source\":\"productcert@siemens.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://cert-portal.siemens.com/productcert/html/ssa-871717.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}" } }
SSA-871717
Vulnerability from csaf_siemens
Published
2024-02-13 00:00
Modified
2024-05-14 00:00
Summary
SSA-871717: Multiple Vulnerabilities in Polarion ALM
Notes
Summary
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation.
Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. \n\nSiemens has released a new version for Polarion ALM and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-871717.json" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-871717.pdf" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-871717.txt" } ], "title": "SSA-871717: Multiple Vulnerabilities in Polarion ALM", "tracking": { "current_release_date": "2024-05-14T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-871717", "initial_release_date": "2024-02-13T00:00:00Z", "revision_history": [ { "date": "2024-02-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-03-12T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added additional mitigation measures, with detailed description in Additional Information" }, { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Polarion ALM" } ], "status": "interim", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2404.0", "product": { "name": "Polarion ALM", "product_id": "1" } } ], "category": "product_name", "name": "Polarion ALM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-50236", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\\SYSTEM.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "In Polarion Windows installation, restrict permissions of BUILTIN\\Users from accessing the entire Polarion installation folders to prevent data corruption. Please refer to the Additional Information section for further details.", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Polarion installations in Linux are not impacted. Hence no actions are required.", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2404.0 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-50236" }, { "cve": "CVE-2024-23813", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "If DOORS connector is not used in the environment, it is advised to limit unauthenticated access within the Apache configuration. For further details, please refer to the Additional Information section.", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "If DOORS connector is used in the environment, restrict access to DOORS connector endpoint to the IP address of the DOORS instance with which Polarion synchronizes its data, which can be done in two ways:\n\n- Firewall rules set by network administrator (preferred and safest method).\n- Configure Apache using guidelines https://httpd.apache.org/docs/2.4/howto/access.html\n\nFor further details, please refer to the Additional Information section.", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2404.0 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-23813" } ] }
ssa-871717
Vulnerability from csaf_siemens
Published
2024-02-13 00:00
Modified
2024-05-14 00:00
Summary
SSA-871717: Multiple Vulnerabilities in Polarion ALM
Notes
Summary
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation.
Siemens has released a new version for Polarion ALM and recommends to update to the latest version.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
{ "document": { "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited. (TLPv2: TLP:CLEAR)", "tlp": { "label": "WHITE" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. \n\nSiemens has released a new version for Polarion ALM and recommends to update to the latest version.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" } ], "publisher": { "category": "vendor", "contact_details": "productcert@siemens.com", "name": "Siemens ProductCERT", "namespace": "https://www.siemens.com" }, "references": [ { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-871717.json" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-871717.pdf" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-871717.txt" } ], "title": "SSA-871717: Multiple Vulnerabilities in Polarion ALM", "tracking": { "current_release_date": "2024-05-14T00:00:00Z", "generator": { "engine": { "name": "Siemens ProductCERT CSAF Generator", "version": "1" } }, "id": "SSA-871717", "initial_release_date": "2024-02-13T00:00:00Z", "revision_history": [ { "date": "2024-02-13T00:00:00Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" }, { "date": "2024-03-12T00:00:00Z", "legacy_version": "1.1", "number": "2", "summary": "Added additional mitigation measures, with detailed description in Additional Information" }, { "date": "2024-05-14T00:00:00Z", "legacy_version": "1.2", "number": "3", "summary": "Added fix for Polarion ALM" } ], "status": "interim", "version": "3" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "\u003cV2404.0", "product": { "name": "Polarion ALM", "product_id": "1" } } ], "category": "product_name", "name": "Polarion ALM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-50236", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\\SYSTEM.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "In Polarion Windows installation, restrict permissions of BUILTIN\\Users from accessing the entire Polarion installation folders to prevent data corruption. Please refer to the Additional Information section for further details.", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "Polarion installations in Linux are not impacted. Hence no actions are required.", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2404.0 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2023-50236" }, { "cve": "CVE-2024-23813", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.", "title": "Summary" } ], "product_status": { "known_affected": [ "1" ] }, "remediations": [ { "category": "mitigation", "details": "If DOORS connector is not used in the environment, it is advised to limit unauthenticated access within the Apache configuration. For further details, please refer to the Additional Information section.", "product_ids": [ "1" ] }, { "category": "mitigation", "details": "If DOORS connector is used in the environment, restrict access to DOORS connector endpoint to the IP address of the DOORS instance with which Polarion synchronizes its data, which can be done in two ways:\n\n- Firewall rules set by network administrator (preferred and safest method).\n- Configure Apache using guidelines https://httpd.apache.org/docs/2.4/howto/access.html\n\nFor further details, please refer to the Additional Information section.", "product_ids": [ "1" ] }, { "category": "vendor_fix", "details": "Update to V2404.0 or later version", "product_ids": [ "1" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "1" ] } ], "title": "CVE-2024-23813" } ] }
ICSA-24-046-14
Vulnerability from csaf_cisa
Published
2024-02-13 00:00
Modified
2024-02-13 00:00
Summary
Siemens Polarion ALM
Notes
Summary
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation.
Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. \n\nSiemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-871717.json" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-871717.pdf" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-871717.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-14 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-046-14.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-14 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-14" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Polarion ALM", "tracking": { "current_release_date": "2024-02-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-046-14", "initial_release_date": "2024-02-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-02-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Polarion ALM", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Polarion ALM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-50236", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\\SYSTEM.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "An administrator can restrict the file and folder path permissions post installation", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-50236" }, { "cve": "CVE-2024-23813", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "If DOORS connector is not used in the environment, add the following in the Apache configuration to restrict unauthenticated access : \n\u0026lt;If \"%{REQUEST_URI} =~ m#^/polarion/doorsconnector/rest#\"\u0026gt; Require all denied \u0026lt;/If\u0026gt;", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "If DOORS connector is used in the environment, limit access to the \ndoorsconnector endpoint to only the specific IP address of the DOORS instance that Polarion synchronizes its data with", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-23813" } ] }
icsa-24-046-14
Vulnerability from csaf_cisa
Published
2024-02-13 00:00
Modified
2024-02-13 00:00
Summary
Siemens Polarion ALM
Notes
Summary
Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation.
Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
General Recommendations
As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download:
https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.
Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity
Additional Resources
For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories
Terms of Use
Siemens Security Advisories are subject to the terms and conditions contained in Siemens' underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter "License Terms"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens' Global Website (https://www.siemens.com/terms_of_use, hereinafter "Terms of Use"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.
Legal Notice
All information products included in https://us-cert.cisa.gov/ics are provided "as is" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.
Advisory Conversion Disclaimer
This CISA CSAF advisory was converted from Siemens ProductCERT's CSAF advisory.
Critical infrastructure sectors
Multiple
Countries/areas deployed
Worldwide
Company headquarters location
Germany
Recommended Practices
CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.
Recommended Practices
Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.
Recommended Practices
Locate control system networks and remote devices behind firewalls and isolate them from business networks.
Recommended Practices
When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.
Recommended Practices
CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.
Recommended Practices
CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.
Recommended Practices
CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.
Recommended Practices
Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.
{ "document": { "acknowledgments": [ { "organization": "Siemens ProductCERT", "summary": "reporting these vulnerabilities to CISA." } ], "category": "csaf_security_advisory", "csaf_version": "2.0", "distribution": { "text": "Disclosure is not limited", "tlp": { "label": "WHITE", "url": "https://us-cert.cisa.gov/tlp/" } }, "lang": "en", "notes": [ { "category": "summary", "text": "Polarion ALM is affected by incorrect default path permissions in installation path, and improper authentication in the REST API endpoints of DOORS connector. An attacker could exploit the vulnerabilities for unauthenticated access, or privilege escalation. \n\nSiemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.", "title": "Summary" }, { "category": "general", "text": "As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens\u0027 operational guidelines for Industrial Security (Download: \nhttps://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals.\nAdditional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity", "title": "General Recommendations" }, { "category": "general", "text": "For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories", "title": "Additional Resources" }, { "category": "legal_disclaimer", "text": "Siemens Security Advisories are subject to the terms and conditions contained in Siemens\u0027 underlying license terms or other applicable agreements previously agreed to with Siemens (hereinafter \"License Terms\"). To the extent applicable to information, software or documentation made available in or through a Siemens Security Advisory, the Terms of Use of Siemens\u0027 Global Website (https://www.siemens.com/terms_of_use, hereinafter \"Terms of Use\"), in particular Sections 8-10 of the Terms of Use, shall apply additionally. In case of conflicts, the License Terms shall prevail over the Terms of Use.", "title": "Terms of Use" }, { "category": "legal_disclaimer", "text": "All information products included in https://us-cert.cisa.gov/ics are provided \"as is\" for informational purposes only. The Department of Homeland Security (DHS) does not provide any warranties of any kind regarding any information contained within. DHS does not endorse any commercial product or service, referenced in this product or otherwise. Further dissemination of this product is governed by the Traffic Light Protocol (TLP) marking in the header. For more information about TLP, see https://us-cert.cisa.gov/tlp/.", "title": "Legal Notice" }, { "category": "other", "text": "This CISA CSAF advisory was converted from Siemens ProductCERT\u0027s CSAF advisory.", "title": "Advisory Conversion Disclaimer" }, { "category": "other", "text": "Multiple", "title": "Critical infrastructure sectors" }, { "category": "other", "text": "Worldwide", "title": "Countries/areas deployed" }, { "category": "other", "text": "Germany", "title": "Company headquarters location" }, { "category": "general", "text": "CISA recommends users take defensive measures to minimize the exploitation risk of this vulnerability.", "title": "Recommended Practices" }, { "category": "general", "text": "Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet.", "title": "Recommended Practices" }, { "category": "general", "text": "Locate control system networks and remote devices behind firewalls and isolate them from business networks.", "title": "Recommended Practices" }, { "category": "general", "text": "When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most recent version available. Also recognize VPN is only as secure as its connected devices.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies.", "title": "Recommended Practices" }, { "category": "general", "text": "Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents.", "title": "Recommended Practices" } ], "publisher": { "category": "other", "contact_details": "central@cisa.dhs.gov", "name": "CISA", "namespace": "https://www.cisa.gov/" }, "references": [ { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - CSAF Version", "url": "https://cert-portal.siemens.com/productcert/csaf/ssa-871717.json" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - HTML Version", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - PDF Version", "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-871717.pdf" }, { "category": "self", "summary": "SSA-871717: Multiple Vulnerabilities in Polarion ALM - TXT Version", "url": "https://cert-portal.siemens.com/productcert/txt/ssa-871717.txt" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-14 JSON", "url": "https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/OT/white/2024/icsa-24-046-14.json" }, { "category": "self", "summary": "ICS Advisory ICSA-24-046-14 - Web Version", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-046-14" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/alerts/ICS-ALERT-10-301-01" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/topics/industrial-control-systems" }, { "category": "external", "summary": "Recommended Practices", "url": "https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/sites/default/files/publications/Cybersecurity_Best_Practices_for_Industrial_Control_Systems.pdf" }, { "category": "external", "summary": "Recommended Practices", "url": "https://www.cisa.gov/uscert/ics/tips/ICS-TIP-12-146-01B" } ], "title": "Siemens Polarion ALM", "tracking": { "current_release_date": "2024-02-13T00:00:00.000000Z", "generator": { "engine": { "name": "CISA CSAF Generator", "version": "1" } }, "id": "ICSA-24-046-14", "initial_release_date": "2024-02-13T00:00:00.000000Z", "revision_history": [ { "date": "2024-02-13T00:00:00.000000Z", "legacy_version": "1.0", "number": "1", "summary": "Publication Date" } ], "status": "final", "version": "1" } }, "product_tree": { "branches": [ { "branches": [ { "branches": [ { "category": "product_version_range", "name": "vers:all/*", "product": { "name": "Polarion ALM", "product_id": "CSAFPID-0001" } } ], "category": "product_name", "name": "Polarion ALM" } ], "category": "vendor", "name": "Siemens" } ] }, "vulnerabilities": [ { "cve": "CVE-2023-50236", "cwe": { "id": "CWE-276", "name": "Incorrect Default Permissions" }, "notes": [ { "category": "summary", "text": "The affected product is vulnerable due to weak file and folder permissions in the installation path. An attacker with local access could exploit this vulnerability to escalate privileges to NT AUTHORITY\\SYSTEM.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "An administrator can restrict the file and folder path permissions post installation", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.8, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2023-50236" }, { "cve": "CVE-2024-23813", "cwe": { "id": "CWE-287", "name": "Improper Authentication" }, "notes": [ { "category": "summary", "text": "The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.", "title": "Summary" } ], "product_status": { "known_affected": [ "CSAFPID-0001" ] }, "remediations": [ { "category": "mitigation", "details": "If DOORS connector is not used in the environment, add the following in the Apache configuration to restrict unauthenticated access : \n\u0026lt;If \"%{REQUEST_URI} =~ m#^/polarion/doorsconnector/rest#\"\u0026gt; Require all denied \u0026lt;/If\u0026gt;", "product_ids": [ "CSAFPID-0001" ] }, { "category": "mitigation", "details": "If DOORS connector is used in the environment, limit access to the \ndoorsconnector endpoint to only the specific IP address of the DOORS instance that Polarion synchronizes its data with", "product_ids": [ "CSAFPID-0001" ] }, { "category": "none_available", "details": "Currently no fix is available", "product_ids": [ "CSAFPID-0001" ] } ], "scores": [ { "cvss_v3": { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" }, "products": [ "CSAFPID-0001" ] } ], "title": "CVE-2024-23813" } ] }
ghsa-f8v6-h8xc-6v8q
Vulnerability from github
Published
2024-02-13 09:30
Modified
2024-02-13 09:30
Severity ?
Details
A vulnerability has been identified in Polarion ALM (All versions). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
{ "affected": [], "aliases": [ "CVE-2024-23813" ], "database_specific": { "cwe_ids": [ "CWE-287" ], "github_reviewed": false, "github_reviewed_at": null, "nvd_published_at": "2024-02-13T09:15:50Z", "severity": "HIGH" }, "details": "A vulnerability has been identified in Polarion ALM (All versions). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.", "id": "GHSA-f8v6-h8xc-6v8q", "modified": "2024-02-13T09:30:33Z", "published": "2024-02-13T09:30:33Z", "references": [ { "type": "ADVISORY", "url": "https://nvd.nist.gov/vuln/detail/CVE-2024-23813" }, { "type": "WEB", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" } ], "schema_version": "1.4.0", "severity": [ { "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "type": "CVSS_V3" } ] }
gsd-2024-23813
Vulnerability from gsd
Modified
2024-01-23 06:02
Details
A vulnerability has been identified in Polarion ALM (All versions). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-23813" ], "details": "A vulnerability has been identified in Polarion ALM (All versions). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code.", "id": "GSD-2024-23813", "modified": "2024-01-23T06:02:22.130868Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2024-23813", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Polarion ALM", "version": { "version_data": [ { "version_affected": "=", "version_value": "All versions" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in Polarion ALM (All versions). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code." } ] }, "impact": { "cvss": [ { "baseScore": 7.3, "baseSeverity": "HIGH", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-287", "lang": "eng", "value": "CWE-287: Improper Authentication" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" } ] } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in Polarion ALM (All versions). The REST API endpoints of doorsconnector of the affected product lacks proper authentication. An unauthenticated attacker could access the endpoints, and potentially execute code." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en Polarion ALM (todas las versiones). Los endpoints de la API REST del conector de puertas del producto afectado carecen de la autenticaci\u00f3n adecuada. Un atacante no autenticado podr\u00eda acceder a los endpoints y potencialmente ejecutar c\u00f3digo." } ], "id": "CVE-2024-23813", "lastModified": "2024-02-13T14:01:00.987", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "LOW", "integrityImpact": "LOW", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 3.4, "source": "productcert@siemens.com", "type": "Primary" } ] }, "published": "2024-02-13T09:15:50.140", "references": [ { "source": "productcert@siemens.com", "url": "https://cert-portal.siemens.com/productcert/html/ssa-871717.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Awaiting Analysis", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-287" } ], "source": "productcert@siemens.com", "type": "Primary" } ] } } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.