CVE-2024-29965 (GCVE-0-2024-29965)

Vulnerability from cvelistv5 – Published: 2024-04-19 04:48 – Updated: 2024-08-02 01:17
VLAI?
Summary
In Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface ("SSH"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.
CWE
  • CWE-922 - Insecure Storage of Sensitive Information
Assigner
Impacted products
Vendor Product Version
Brocade Brocade SANnav Affected: before v2.3.1, and v2.3.0a
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "sannav",
            "vendor": "brocade",
            "versions": [
              {
                "lessThan": "2.3.0a",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-29965",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-20T03:00:28.543253Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:56:52.975Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T01:17:58.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23250"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Brocade SANnav",
          "vendor": "Brocade",
          "versions": [
            {
              "status": "affected",
              "version": " before v2.3.1, and v2.3.0a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\"SSH\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\"SSH\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-37",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-37 Retrieve Embedded Sensitive Data"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-922",
              "description": "CWE-922: Insecure Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T04:55:03.276Z",
        "orgId": "87b297d7-335e-4844-9551-11b97995a791",
        "shortName": "brocade"
      },
      "references": [
        {
          "url": "https://support.broadcom.com/external/content/SecurityAdvisories/0/23250"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Insecure backup",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "87b297d7-335e-4844-9551-11b97995a791",
    "assignerShortName": "brocade",
    "cveId": "CVE-2024-29965",
    "datePublished": "2024-04-19T04:48:46.279Z",
    "dateReserved": "2024-03-22T05:32:26.687Z",
    "dateUpdated": "2024-08-02T01:17:58.599Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"\\nIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\\\"SSH\\\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\\n\\n\"}, {\"lang\": \"es\", \"value\": \"En Brocade SANnav anterior a v2.3.1 y v2.3.0a, es posible realizar una copia de seguridad del dispositivo desde la interfaz web o la interfaz de l\\u00ednea de comandos (\\\"SSH\\\"). Las copias de seguridad resultantes son legibles en todo el mundo. Un atacante local puede recuperar archivos de respaldo, restaurarlos en un nuevo dispositivo malicioso y recuperar las contrase\\u00f1as de todos los conmutadores.\"}]",
      "id": "CVE-2024-29965",
      "lastModified": "2024-11-21T09:08:42.927",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"sirt@brocade.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N\", \"baseScore\": 6.8, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"REQUIRED\", \"scope\": \"CHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 2.3, \"impactScore\": 4.0}]}",
      "published": "2024-04-19T05:15:49.390",
      "references": "[{\"url\": \"https://support.broadcom.com/external/content/SecurityAdvisories/0/23250\", \"source\": \"sirt@brocade.com\"}, {\"url\": \"https://support.broadcom.com/external/content/SecurityAdvisories/0/23250\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "sirt@brocade.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"sirt@brocade.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-922\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-29965\",\"sourceIdentifier\":\"sirt@brocade.com\",\"published\":\"2024-04-19T05:15:49.390\",\"lastModified\":\"2025-02-04T15:45:17.783\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\\\"SSH\\\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\\n\\n\"},{\"lang\":\"es\",\"value\":\"En Brocade SANnav anterior a v2.3.1 y v2.3.0a, es posible realizar una copia de seguridad del dispositivo desde la interfaz web o la interfaz de l\u00ednea de comandos (\\\"SSH\\\"). Las copias de seguridad resultantes son legibles en todo el mundo. Un atacante local puede recuperar archivos de respaldo, restaurarlos en un nuevo dispositivo malicioso y recuperar las contrase\u00f1as de todos los conmutadores.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"sirt@brocade.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":2.3,\"impactScore\":4.0},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N\",\"baseScore\":5.9,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"REQUIRED\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.5,\"impactScore\":4.0}]},\"weaknesses\":[{\"source\":\"sirt@brocade.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-922\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-922\"}]}],\"configurations\":[{\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:a:broadcom:brocade_sannav:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"2.3.0a\",\"matchCriteriaId\":\"303EE152-4CED-4655-B035-CB3B91E5E288\"}]}]}],\"references\":[{\"url\":\"https://support.broadcom.com/external/content/SecurityAdvisories/0/23250\",\"source\":\"sirt@brocade.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://support.broadcom.com/external/content/SecurityAdvisories/0/23250\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://support.broadcom.com/external/content/SecurityAdvisories/0/23250\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T01:17:58.599Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-29965\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-04-20T03:00:28.543253Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:brocade:sannav:*:*:*:*:*:*:*:*\"], \"vendor\": \"brocade\", \"product\": \"sannav\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"2.3.0a\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-04-20T02:58:54.579Z\"}}], \"cna\": {\"title\": \"Insecure backup\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-37\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-37 Retrieve Embedded Sensitive Data\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Brocade\", \"product\": \"Brocade SANnav\", \"versions\": [{\"status\": \"affected\", \"version\": \" before v2.3.1, and v2.3.0a\"}], \"defaultStatus\": \"affected\"}], \"references\": [{\"url\": \"https://support.broadcom.com/external/content/SecurityAdvisories/0/23250\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\\\"SSH\\\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eIn Brocade SANnav before v2.3.1, and v2.3.0a, it is possible to back up the appliance from the web interface or the command line interface (\\\"SSH\\\"). The resulting backups are world-readable. A local attacker can recover backup files, restore them to a new malicious appliance, and retrieve the passwords of all the switches.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-922\", \"description\": \"CWE-922: Insecure Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"shortName\": \"brocade\", \"dateUpdated\": \"2024-04-19T04:55:03.276Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-29965\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T01:17:58.599Z\", \"dateReserved\": \"2024-03-22T05:32:26.687Z\", \"assignerOrgId\": \"87b297d7-335e-4844-9551-11b97995a791\", \"datePublished\": \"2024-04-19T04:48:46.279Z\", \"assignerShortName\": \"brocade\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…