CVE-2024-5659 (GCVE-0-2024-5659)

Vulnerability from cvelistv5 – Published: 2024-06-14 16:42 – Updated: 2024-08-01 21:18
VLAI?
Summary
Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port. If exploited, the availability of the device would be compromised.
CWE
  • CWE-670 - Always-Incorrect Control Flow Implementation
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "controllogix_5580",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "34.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "guardlogix_5580",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "34.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:1756_en4:0:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "1756_en4",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "4.001"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:compact_logix_5480:34.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "compact_logix_5480",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "34.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:a:rockwellautomation:compact_guardlogix_5480:34.011:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "compact_guardlogix_5480",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "34.011"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "compactlogix",
            "vendor": "rockwellautomation",
            "versions": [
              {
                "status": "affected",
                "version": "5480"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5659",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-15T19:57:53.882617Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-15T20:23:20.243Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:18:06.865Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "ControlLogix\u00ae 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "34.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GuardLogix 5580",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "34.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "1756-EN4",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "4.001"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5380",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "34.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Compact GuardLogix 5380",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "34.011"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CompactLogix 5480",
          "vendor": "Rockwell Automation",
          "versions": [
            {
              "status": "affected",
              "version": "34.011"
            }
          ]
        }
      ],
      "datePublic": "2024-06-13T13:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eRockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eabnormal packets to the \u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003emDNS port.\u0026nbsp;\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eIf exploited, the availability of the device would be compromised.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\u00a0If exploited, the availability of the device would be compromised."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-624",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-624 Hardware Fault Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-670",
              "description": "CWE-670 Always-Incorrect Control Flow Implementation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-06-14T16:42:20.699Z",
        "orgId": "b73dd486-f505-4403-b634-40b078b177f0",
        "shortName": "Rockwell"
      },
      "references": [
        {
          "url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in firmware revision\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in firmware revision\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e1756-EN4\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV4.001\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV6.001 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eCompact GuardLogix \u003c/a\u003e\u003cb\u003e\u0026nbsp;\u003c/b\u003e5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5480\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\n\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Users who do not use \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAutomatic Policy Deployment (APD)\u003c/a\u003e\u0026nbsp;should block \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003emDNS port, 5353\u003c/a\u003e\u0026nbsp;to help prevent communication.\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Enable CIP \u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003e\u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eSecurity. \u003c/a\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf\"\u003eCIP Security with Rockwell Automation Products Application Technique\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Affected Product\n\nFirst Known in firmware revision\n\nCorrected in firmware revision\n\nControlLogix\u00ae 5580\n\nV34.011\n\nV34.014, V35.013, V36.011 and later\n\nGuardLogix 5580\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\n1756-EN4\n\nV4.001\n\nV6.001 and later\n\nCompactLogix 5380\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\nCompact GuardLogix \u00a05380\n\nV34.011\n\nV34.014, V35.013, V36.011 and later \n\nCompactLogix 5480\n\nV34.011\n\nV34.014, V35.013, V36.011 and later\n\n\n\n\nMitigations and Workarounds\n\nUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\n\n\u00b7 \u00a0 \u00a0 \u00a0 Users who do not use  CIP Security with Rockwell Automation Products Application Technique https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf \n\n\u00b7 \u00a0 \u00a0 \u00a0  Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Rockwell Automation Multicast Request Causes major nonrecoverable fault on Select Controllers",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
    "assignerShortName": "Rockwell",
    "cveId": "CVE-2024-5659",
    "datePublished": "2024-06-14T16:42:20.699Z",
    "dateReserved": "2024-06-05T16:47:18.275Z",
    "dateUpdated": "2024-08-01T21:18:06.865Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "descriptions": "[{\"lang\": \"en\", \"value\": \"Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\\u00a0If exploited, the availability of the device would be compromised.\"}, {\"lang\": \"es\", \"value\": \"Rockwell Automation fue informado de una vulnerabilidad que hace que todos los controladores afectados en la misma red produzcan una falla importante no recuperable (MNRF/Assert). Esta vulnerabilidad podr\\u00eda explotarse enviando paquetes anormales al puerto mDNS. Si se explota, la disponibilidad del dispositivo se ver\\u00eda comprometida.\"}]",
      "id": "CVE-2024-5659",
      "lastModified": "2024-11-21T09:48:06.543",
      "metrics": "{\"cvssMetricV40\": [{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"4.0\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\", \"baseScore\": 8.3, \"baseSeverity\": \"HIGH\", \"attackVector\": \"ADJACENT\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnerableSystemConfidentiality\": \"NONE\", \"vulnerableSystemIntegrity\": \"NONE\", \"vulnerableSystemAvailability\": \"HIGH\", \"subsequentSystemConfidentiality\": \"NONE\", \"subsequentSystemIntegrity\": \"NONE\", \"subsequentSystemAvailability\": \"HIGH\", \"exploitMaturity\": \"NOT_DEFINED\", \"confidentialityRequirements\": \"NOT_DEFINED\", \"integrityRequirements\": \"NOT_DEFINED\", \"availabilityRequirements\": \"NOT_DEFINED\", \"modifiedAttackVector\": \"NOT_DEFINED\", \"modifiedAttackComplexity\": \"NOT_DEFINED\", \"modifiedAttackRequirements\": \"NOT_DEFINED\", \"modifiedPrivilegesRequired\": \"NOT_DEFINED\", \"modifiedUserInteraction\": \"NOT_DEFINED\", \"modifiedVulnerableSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedVulnerableSystemIntegrity\": \"NOT_DEFINED\", \"modifiedVulnerableSystemAvailability\": \"NOT_DEFINED\", \"modifiedSubsequentSystemConfidentiality\": \"NOT_DEFINED\", \"modifiedSubsequentSystemIntegrity\": \"NOT_DEFINED\", \"modifiedSubsequentSystemAvailability\": \"NOT_DEFINED\", \"safety\": \"NOT_DEFINED\", \"automatable\": \"NOT_DEFINED\", \"recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\"}}]}",
      "published": "2024-06-14T17:15:51.600",
      "references": "[{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html\", \"source\": \"PSIRT@rockwellautomation.com\"}, {\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\"}]",
      "sourceIdentifier": "PSIRT@rockwellautomation.com",
      "vulnStatus": "Awaiting Analysis",
      "weaknesses": "[{\"source\": \"PSIRT@rockwellautomation.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-670\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-5659\",\"sourceIdentifier\":\"PSIRT@rockwellautomation.com\",\"published\":\"2024-06-14T17:15:51.600\",\"lastModified\":\"2025-03-03T19:37:09.243\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\u00a0If exploited, the availability of the device would be compromised.\"},{\"lang\":\"es\",\"value\":\"Rockwell Automation fue informado de una vulnerabilidad que hace que todos los controladores afectados en la misma red produzcan una falla importante no recuperable (MNRF/Assert). Esta vulnerabilidad podr\u00eda explotarse enviando paquetes anormales al puerto mDNS. Si se explota, la disponibilidad del dispositivo se ver\u00eda comprometida.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":8.3,\"baseSeverity\":\"HIGH\",\"attackVector\":\"ADJACENT\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"NONE\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H\",\"baseScore\":6.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"PSIRT@rockwellautomation.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-670\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-670\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:34.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"02F74A5B-BE74-4F8B-B8D3-D1D48A6C5CA0\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:34.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D8B88DDE-9002-4EE8-BAA8-73330CB0BE50\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"006B7683-9FDF-4748-BA28-2EA22613E092\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:1756-en4_firmware:4.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3B050175-3923-4B1E-AE98-53AF028EE8AA\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:1756-en4:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"6935642C-4CBF-4B4F-A509-561B3E39A66B\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:34.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EC388DFC-DA67-44B6-AE97-731B33F38992\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EDD040ED-B44C-47D0-B4D4-729C378C4F68\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:34.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"01EB5C9E-A10F-4D53-AF3D-38055F966BD6\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"62414E65-73C7-4172-B7BF-F40A66AFBB90\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:34.011:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"A913AF0F-DA08-4FE9-9E94-AA1D6227981B\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"80F4F5BE-07DF-402A-BF98-34FBA6A11968\"}]}]}],\"references\":[{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html\",\"source\":\"PSIRT@rockwellautomation.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T21:18:06.865Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-5659\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-06-15T19:57:53.882617Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"controllogix_5580\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"guardlogix_5580\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:rockwellautomation:1756_en4:0:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"1756_en4\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.001\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:rockwellautomation:compact_logix_5480:34.011:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"compact_logix_5480\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:a:rockwellautomation:compact_guardlogix_5480:34.011:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"compact_guardlogix_5480\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unknown\"}, {\"cpes\": [\"cpe:2.3:h:rockwellautomation:compactlogix:*:*:*:*:*:*:*:*\"], \"vendor\": \"rockwellautomation\", \"product\": \"compactlogix\", \"versions\": [{\"status\": \"affected\", \"version\": \"5480\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-06-15T20:01:15.688Z\"}}], \"cna\": {\"title\": \"Rockwell Automation Multicast Request Causes major nonrecoverable fault on Select Controllers\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"impacts\": [{\"capecId\": \"CAPEC-624\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-624 Hardware Fault Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"ADJACENT\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Rockwell Automation\", \"product\": \"ControlLogix\\u00ae 5580\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"GuardLogix 5580\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"1756-EN4\", \"versions\": [{\"status\": \"affected\", \"version\": \"4.001\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"CompactLogix 5380\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"Compact GuardLogix 5380\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Rockwell Automation\", \"product\": \"CompactLogix 5480\", \"versions\": [{\"status\": \"affected\", \"version\": \"34.011\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Affected Product\\n\\nFirst Known in firmware revision\\n\\nCorrected in firmware revision\\n\\nControlLogix\\u00ae 5580\\n\\nV34.011\\n\\nV34.014, V35.013, V36.011 and later\\n\\nGuardLogix 5580\\n\\nV34.011\\n\\nV34.014, V35.013, V36.011 and later \\n\\n1756-EN4\\n\\nV4.001\\n\\nV6.001 and later\\n\\nCompactLogix 5380\\n\\nV34.011\\n\\nV34.014, V35.013, V36.011 and later \\n\\nCompact GuardLogix \\u00a05380\\n\\nV34.011\\n\\nV34.014, V35.013, V36.011 and later \\n\\nCompactLogix 5480\\n\\nV34.011\\n\\nV34.014, V35.013, V36.011 and later\\n\\n\\n\\n\\nMitigations and Workarounds\\n\\nUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\\n\\n\\u00b7 \\u00a0 \\u00a0 \\u00a0 Users who do not use  CIP Security with Rockwell Automation Products Application Technique https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf \\n\\n\\u00b7 \\u00a0 \\u00a0 \\u00a0  Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eAffected Product\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eFirst Known in firmware revision\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in firmware revision\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\\u00ae 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix 5580\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e1756-EN4\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV4.001\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV6.001 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eCompact GuardLogix \u003c/a\u003e\u003cb\u003e\u0026nbsp;\u003c/b\u003e5380\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later \u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eCompactLogix 5480\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eV34.014, V35.013, V36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\u003cbr\u003e\\n\\n\u003cp\u003e\u003cb\u003eMitigations and Workarounds\u003c/b\u003e\u003c/p\u003e\u003cp\u003eUsers using the affected software and who are not able to upgrade to one of the corrected versions are encouraged to apply the risk mitigations, where possible.\u003c/p\u003e\u003cp\u003e\\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Users who do not use \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eAutomatic Policy Deployment (APD)\u003c/a\u003e\u0026nbsp;should block \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003emDNS port, 5353\u003c/a\u003e\u0026nbsp;to help prevent communication.\u003c/p\u003e\u003cp\u003e\\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; Enable CIP \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eSecurity. \u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf\\\"\u003eCIP Security with Rockwell Automation Products Application Technique\u003c/a\u003e\u003c/p\u003e\u003cp\u003e\\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\\\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/p\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"datePublic\": \"2024-06-13T13:00:00.000Z\", \"references\": [{\"url\": \"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port.\\u00a0If exploited, the availability of the device would be compromised.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eRockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending \u003c/span\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003e\u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003eabnormal packets to the \u003c/a\u003e\u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\"\u003emDNS port.\u0026nbsp;\u003c/a\u003e\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eIf exploited, the availability of the device would be compromised.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-670\", \"description\": \"CWE-670 Always-Incorrect Control Flow Implementation\"}]}], \"providerMetadata\": {\"orgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"shortName\": \"Rockwell\", \"dateUpdated\": \"2024-06-14T16:42:20.699Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-5659\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T21:18:06.865Z\", \"dateReserved\": \"2024-06-05T16:47:18.275Z\", \"assignerOrgId\": \"b73dd486-f505-4403-b634-40b078b177f0\", \"datePublished\": \"2024-06-14T16:42:20.699Z\", \"assignerShortName\": \"Rockwell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…