cve-2024-7392
Vulnerability from cvelistv5
Published
2024-11-22 21:31
Modified
2024-11-22 21:31
Summary
ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability
Impacted products
ChargePointHome Flex
Show details on NVD website


{
  "containers": {
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Home Flex",
          "vendor": "ChargePoint",
          "versions": [
            {
              "status": "affected",
              "version": "5.5.3.13"
            }
          ]
        }
      ],
      "dateAssigned": "2024-08-01T15:11:59.373-05:00",
      "datePublic": "2024-08-01T15:21:38.604-05:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of ChargePoint Home Flex charging devices. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the connection handling of the Bluetooth Low Energy interface. The issue results from limiting the number of active connections to the product. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-21455."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "baseScore": 4.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.0"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-410",
              "description": "CWE-410: Insufficient Resource Pool",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-22T21:31:27.805Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "name": "ZDI-24-1047",
          "tags": [
            "x_research-advisory"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-24-1047/"
        }
      ],
      "source": {
        "lang": "en",
        "value": "Todd Manning"
      },
      "title": "ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2024-7392",
    "datePublished": "2024-11-22T21:31:27.805Z",
    "dateReserved": "2024-08-01T20:11:59.349Z",
    "dateUpdated": "2024-11-22T21:31:27.805Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2024-7392\",\"sourceIdentifier\":\"zdi-disclosures@trendmicro.com\",\"published\":\"2024-11-22T22:15:18.013\",\"lastModified\":\"2024-11-22T22:15:18.013\",\"vulnStatus\":\"Received\",\"descriptions\":[{\"lang\":\"en\",\"value\":\"ChargePoint Home Flex Bluetooth Low Energy Denial-of-Service Vulnerability. This vulnerability allows network-adjacent attackers to create a denial-of-service condition on affected installations of ChargePoint Home Flex charging devices. Authentication is not required to exploit this vulnerability.\\n\\nThe specific flaw exists within the connection handling of the Bluetooth Low Energy interface. The issue results from limiting the number of active connections to the product. An attacker can leverage this vulnerability to create a denial-of-service condition on the system. Was ZDI-CAN-21455.\"}],\"metrics\":{\"cvssMetricV30\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.0\",\"vectorString\":\"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L\",\"baseScore\":4.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"ADJACENT_NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"NONE\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"zdi-disclosures@trendmicro.com\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-410\"}]}],\"references\":[{\"url\":\"https://www.zerodayinitiative.com/advisories/ZDI-24-1047/\",\"source\":\"zdi-disclosures@trendmicro.com\"}]}}"
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.