gsd-2021-21595
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2021-21595",
    "description": "Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.",
    "id": "GSD-2021-21595"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2021-21595"
      ],
      "details": "Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity.",
      "id": "GSD-2021-21595",
      "modified": "2023-12-13T01:23:11.250531Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "secure@dell.com",
        "DATE_PUBLIC": "2021-08-10",
        "ID": "CVE-2021-21595",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "PowerScale OneFS",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "8.2.x - 9.1.1.x"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Dell"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity."
          }
        ]
      },
      "impact": {
        "cvss": {
          "baseScore": 6.0,
          "baseSeverity": "Medium",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
          "version": "3.1"
        }
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "lang": "eng",
                "value": "CWE-77: Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.dell.com/support/kbdoc/000190408",
            "refsource": "MISC",
            "url": "https://www.dell.com/support/kbdoc/000190408"
          }
        ]
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:o:dell:emc_powerscale_onefs:8.2.2:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:o:dell:emc_powerscale_onefs:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "9.2.0",
                "versionStartIncluding": "9.0.0.0",
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "ID": "CVE-2021-21595"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "Dell EMC PowerScale OneFS versions 8.2.x - 9.1.1.x contain an improper neutralization of special elements used in an OS command. This vulnerability could allow the compadmin user to elevate privileges. This only impacts Smartlock WORM compliance mode clusters as a critical vulnerability and Dell recommends to update/upgrade at the earliest opportunity."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-77"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "N/A",
              "refsource": "CONFIRM",
              "tags": [
                "Patch",
                "Vendor Advisory"
              ],
              "url": "https://www.dell.com/support/kbdoc/000190408"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV2": {
          "acInsufInfo": false,
          "cvssV2": {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 4.6,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "PARTIAL",
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
            "version": "2.0"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 6.4,
          "obtainAllPrivilege": false,
          "obtainOtherPrivilege": false,
          "obtainUserPrivilege": false,
          "severity": "MEDIUM",
          "userInteractionRequired": false
        },
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "exploitabilityScore": 0.8,
          "impactScore": 5.9
        }
      },
      "lastModifiedDate": "2021-08-25T00:43Z",
      "publishedDate": "2021-08-16T22:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.