gsd-2021-32771
Vulnerability from gsd
Modified
2023-12-13 01:23
Details
Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have joined an RPL DODAG. After that, an attacker can send a DAO packet with a Target option that contains a prefix length larger than 128 bits. The problem was fixed after the release of Contiki-NG 4.7. Users unable to upgrade may apply the patch in Contiki-NG PR #1615.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2021-32771", "description": "Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have joined an RPL DODAG. After that, an attacker can send a DAO packet with a Target option that contains a prefix length larger than 128 bits. The problem was fixed after the release of Contiki-NG 4.7. Users unable to upgrade may apply the patch in Contiki-NG PR #1615.", "id": "GSD-2021-32771" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2021-32771" ], "details": "Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have joined an RPL DODAG. After that, an attacker can send a DAO packet with a Target option that contains a prefix length larger than 128 bits. The problem was fixed after the release of Contiki-NG 4.7. Users unable to upgrade may apply the patch in Contiki-NG PR #1615.", "id": "GSD-2021-32771", "modified": "2023-12-13T01:23:09.025807Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security-advisories@github.com", "ID": "CVE-2021-32771", "STATE": "PUBLIC", "TITLE": "Buffer overflow in contiki-ng" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "contiki-ng", "version": { "version_data": [ { "version_value": "\u003c 4.8" } ] } } ] }, "vendor_name": "contiki-ng" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have joined an RPL DODAG. After that, an attacker can send a DAO packet with a Target option that contains a prefix length larger than 128 bits. The problem was fixed after the release of Contiki-NG 4.7. Users unable to upgrade may apply the patch in Contiki-NG PR #1615." } ] }, "impact": { "cvss": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-jqjf-v7v9-xp6w", "refsource": "CONFIRM", "url": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-jqjf-v7v9-xp6w" }, { "name": "https://github.com/contiki-ng/contiki-ng/pull/1615", "refsource": "MISC", "url": "https://github.com/contiki-ng/contiki-ng/pull/1615" }, { "name": "https://github.com/contiki-ng/contiki-ng/pull/1615/commits/587ae59956e00316fd44fd7072ac3a6a07b4b20f", "refsource": "MISC", "url": "https://github.com/contiki-ng/contiki-ng/pull/1615/commits/587ae59956e00316fd44fd7072ac3a6a07b4b20f" }, { "name": "https://github.com/contiki-ng/contiki-ng/releases/tag/release%2Fv4.8", "refsource": "MISC", "url": "https://github.com/contiki-ng/contiki-ng/releases/tag/release%2Fv4.8" } ] }, "source": { "advisory": "GHSA-jqjf-v7v9-xp6w", "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:contiki-ng:contiki-ng:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.8", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "security-advisories@github.com", "ID": "CVE-2021-32771" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Contiki-NG is an open-source, cross-platform operating system for IoT devices. In affected versions it is possible to cause a buffer overflow when copying an IPv6 address prefix in the RPL-Classic implementation in Contiki-NG. In order to trigger the vulnerability, the Contiki-NG system must have joined an RPL DODAG. After that, an attacker can send a DAO packet with a Target option that contains a prefix length larger than 128 bits. The problem was fixed after the release of Contiki-NG 4.7. Users unable to upgrade may apply the patch in Contiki-NG PR #1615." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-120" } ] } ] }, "references": { "reference_data": [ { "name": "https://github.com/contiki-ng/contiki-ng/pull/1615/commits/587ae59956e00316fd44fd7072ac3a6a07b4b20f", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://github.com/contiki-ng/contiki-ng/pull/1615/commits/587ae59956e00316fd44fd7072ac3a6a07b4b20f" }, { "name": "https://github.com/contiki-ng/contiki-ng/pull/1615", "refsource": "MISC", "tags": [ "Patch", "Third Party Advisory" ], "url": "https://github.com/contiki-ng/contiki-ng/pull/1615" }, { "name": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-jqjf-v7v9-xp6w", "refsource": "CONFIRM", "tags": [ "Third Party Advisory" ], "url": "https://github.com/contiki-ng/contiki-ng/security/advisories/GHSA-jqjf-v7v9-xp6w" }, { "name": "https://github.com/contiki-ng/contiki-ng/releases/tag/release%2Fv4.8", "refsource": "MISC", "tags": [ "Third Party Advisory" ], "url": "https://github.com/contiki-ng/contiki-ng/releases/tag/release%2Fv4.8" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "HIGH", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.1, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.2, "impactScore": 5.9 } }, "lastModifiedDate": "2022-08-10T18:08Z", "publishedDate": "2022-08-04T21:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.