gsd-2022-32257
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2022-32257", "id": "GSD-2022-32257" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2022-32257" ], "details": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution.", "id": "GSD-2022-32257", "modified": "2023-12-13T01:19:12.899892Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productcert@siemens.com", "ID": "CVE-2022-32257", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "SINEMA Remote Connect Server", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "V3.2" } ] } } ] }, "vendor_name": "Siemens" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution." } ] }, "impact": { "cvss": [ { "baseScore": 9.8, "baseSeverity": "CRITICAL", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-284", "lang": "eng", "value": "CWE-284: Improper Access Control" } ] } ] }, "references": { "reference_data": [ { "name": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html", "refsource": "MISC", "url": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html" } ] } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:a:siemens:sinema_remote_connect_server:*:*:*:*:*:*:*:*", "matchCriteriaId": "BA2839E7-E397-4D69-865B-439F0017D540", "versionEndExcluding": "3.2", "vulnerable": true } ], "negate": false, "operator": "OR" } ] } ], "descriptions": [ { "lang": "en", "value": "A vulnerability has been identified in SINEMA Remote Connect Server (All versions \u003c V3.2). The affected application consists of a web service that lacks proper access control for some of the endpoints. This could lead to unauthorized access to resources and potentially lead to code execution." }, { "lang": "es", "value": "Se ha identificado una vulnerabilidad en SINEMA Remote Connect Server (todas las versiones \u0026lt; V3.2). La aplicaci\u00f3n afectada consiste en un servicio web que carece de un control de acceso adecuado para algunos de los endpoints. Esto podr\u00eda provocar un acceso no autorizado a los recursos y potencialmente provocar la ejecuci\u00f3n de c\u00f3digo." } ], "id": "CVE-2022-32257", "lastModified": "2024-03-25T16:29:15.437", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "productcert@siemens.com", "type": "Secondary" } ], "cvssMetricV40": [ { "cvssData": { "Availability Requirements": "NOT DEFINED", "Modified Vulnerable System Availability": "NOT DEFINED", "attackComplexity": "LOW", "attackRequirements": "NONE", "attackVector": "NETWORK", "automatable": "NOT DEFINED ", "baseScore": 0.0, "baseSeverity": "NONE", "confidentialityRequirements": "HIGH", "exploitMaturity": "NOT DEFINED", "integrityRequirements": "HIGH", "modifiedAttackComplexity": "NOT DEFINED", "modifiedAttackRequirements": "NOT DEFINED", "modifiedAttackVector": "NOT DEFINED", "modifiedPrivilegesRequired": "NOT DEFINED", "modifiedSubsequentSystemAvailability": "NOT DEFINED", "modifiedSubsequentSystemIntegrity": "NOT DEFINED", "modifiedUserInteraction": "NOT DEFINED", "modifiedVulnerableSystemConfidentiality": "NOT DEFINED", "modifiedVulnerableSystemIntegrity": "NOT DEFINED", "privilegesRequired": "NONE", "providerUrgency": "NOT DEFINED ", "recovery": "NOT DEFINED", "safety": "NOT DEFINED", "subsequentSystemAvailability": "HIGH", "subsequentSystemConfidentiality": "HIGH", "subsequentSystemIntegrity": "HIGH", "userInteraction": "NONE", "valueDensity": "NOT DEFINED", "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:H/IR:H/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X", "version": "4.0", "vulnerabilityResponseEffort": "NOT DEFINED ", "vulnerableSystemAvailability": "HIGH", "vulnerableSystemConfidentiality": "HIGH", "vulnerableSystemIntegrity": "HIGH" }, "exploitabilityScore": 0.0, "impactScore": 0.0, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2024-03-12T11:15:45.210", "references": [ { "source": "productcert@siemens.com", "tags": [ "Patch", "Vendor Advisory" ], "url": "https://cert-portal.siemens.com/productcert/html/ssa-576771.html" } ], "sourceIdentifier": "productcert@siemens.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-284" } ], "source": "productcert@siemens.com", "type": "Primary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.