gsd-2022-45139
Vulnerability from gsd
Modified
2023-12-13 01:19
Details
A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.
Aliases
Aliases



{
  "GSD": {
    "alias": "CVE-2022-45139",
    "description": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.",
    "id": "GSD-2022-45139"
  },
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2022-45139"
      ],
      "details": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality.",
      "id": "GSD-2022-45139",
      "modified": "2023-12-13T01:19:24.532429Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "info@cert.vde.com",
        "ID": "CVE-2022-45139",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "Compact Controller CC100 (751-9301)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW16",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Edge Controller (752-8303/8000-002)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW18",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "PFC100 (750-81xx/xxx-xxx)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW16",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "PFC200 (750-82xx/xxx-xxx)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW16",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Touch Panel 600 Advanced Line (762-5xxx)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW16",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Touch Panel 600 Marine Line (762-6xxx)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW16",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "Touch Panel 600 Standard Line (762-4xxx)",
                    "version": {
                      "version_data": [
                        {
                          "version_value": "not down converted",
                          "x_cve_json_5_version_data": {
                            "defaultStatus": "unaffected",
                            "versions": [
                              {
                                "lessThan": "FW22",
                                "status": "affected",
                                "version": "FW16",
                                "versionType": "custom"
                              },
                              {
                                "status": "unaffected",
                                "version": "FW22 Patch 1"
                              },
                              {
                                "status": "affected",
                                "version": "FW23"
                              }
                            ]
                          }
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "WAGO"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "Ryan Pickren of Georgia Institute of Technologys Cyber-Physical Security Lab"
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-346",
                "lang": "eng",
                "value": "CWE-346 Origin Validation Error"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://cert.vde.com/en/advisories/VDE-2022-060/",
            "refsource": "MISC",
            "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
          }
        ]
      },
      "source": {
        "defect": [
          "CERT@VDE#64160"
        ],
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "configurations": {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:751-9301_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "16",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:751-9301_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:751-9301_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:751-9301:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:752-8303\\/8000-002_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "18",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:752-8303\\/8000-002_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:752-8303\\/8000-002_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:752-8303\\/8000-002:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc100_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "16",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc100_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc100_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:pfc100:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "16",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_advanced_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "16",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_advanced_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_advanced_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:touch_panel_600_advanced:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_marine_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "16",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_marine_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_marine_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:touch_panel_600_marine:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          },
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_standard_firmware:*:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "versionEndExcluding": "22",
                    "versionStartIncluding": "16",
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_standard_firmware:22:-:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:touch_panel_600_standard_firmware:23:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:touch_panel_600_standard:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      },
      "cve": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "ID": "CVE-2022-45139"
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "en",
              "value": "A CORS Misconfiguration in the web-based management allows a malicious third party webserver to misuse all basic information pages on the webserver. In combination with CVE-2022-45138 this could lead to disclosure of device information like CPU diagnostics. As there is just a limited amount of information readable the impact only affects a small subset of confidentiality."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "en",
                  "value": "CWE-346"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2022-060/",
              "refsource": "MISC",
              "tags": [
                "Third Party Advisory"
              ],
              "url": "https://cert.vde.com/en/advisories/VDE-2022-060/"
            }
          ]
        }
      },
      "impact": {
        "baseMetricV3": {
          "cvssV3": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "exploitabilityScore": 3.9,
          "impactScore": 1.4
        }
      },
      "lastModifiedDate": "2023-03-07T22:54Z",
      "publishedDate": "2023-02-27T15:15Z"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.