GSD-2023-0754
Vulnerability from gsd - Updated: 2023-12-13 01:20Details
The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code.
Aliases
Aliases
{
"GSD": {
"alias": "CVE-2023-0754",
"id": "GSD-2023-0754"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-0754"
],
"details": "The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code.",
"id": "GSD-2023-0754",
"modified": "2023-12-13T01:20:23.199948Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2023-0754",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ThingWorx Edge C-SDK",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v2.2.12.1052 "
}
]
}
},
{
"product_name": "ThingWorx Edge MicroServer (EMS)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v5.4.10.0 "
}
]
}
},
{
"product_name": "Kepware KEPServerEX",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v6.12 "
}
]
}
},
{
"product_name": "ThingWorx Kepware Server ",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v6.12 "
}
]
}
},
{
"product_name": "ThingWorx Industrial Connectivity",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions "
}
]
}
},
{
"product_name": "ThingWorx Kepware Edge",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v1.5"
}
]
}
}
]
},
"vendor_name": "PTC"
},
{
"product": {
"product_data": [
{
"product_name": ".NET-SDK",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v5.8.4.971 "
}
]
}
}
]
},
"vendor_name": "Microsoft"
},
{
"product": {
"product_data": [
{
"product_name": "KEPServer Enterprise ",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v6.12"
}
]
}
}
]
},
"vendor_name": "Rockwell Automation "
},
{
"product": {
"product_data": [
{
"product_name": "Digital Industrial Gateway Server ",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "0",
"version_value": "v7.612"
}
]
}
}
]
},
"vendor_name": "General Electric "
}
]
}
},
"credits": [
{
"lang": "en",
"value": "Chris Anastasio and Steven Seeley of Incite Team reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code."
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-190",
"lang": "eng",
"value": "CWE-190 Integer Overflow or Wraparound"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
]
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003ePTC has released the following resolutions:\u003c/p\u003e\n\n\u003cp\u003eUpdate the impacted product to the latest version:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge C-SDK: 3.0.0 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\n.NET-SDK: v5.8.5 or later.\u003c/p\u003e\n\n\u003cp\u003eFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is \u003cb\u003enot\u003c/b\u003e enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nKepware KEPServerEX: v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nThingWorx Kepware Edge: v1.6 or later.\u003c/p\u003e\n\n\u003cp\u003eThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\u003c/p\u003e\n\n\u003cp\u003e\u00b7 \u0026nbsp; \u0026nbsp; \u0026nbsp; \u0026nbsp;\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\u003c/p\u003e\n\n\u003cp\u003eFor\nmore information see PTC\u2019s \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS385715\"\u003eCustomer Support Article\n\u003c/a\u003e.\u003c/p\u003e\n\n\n\n\n\n\u003cbr\u003e"
}
],
"value": "PTC has released the following resolutions:\n\n\n\nUpdate the impacted product to the latest version:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge C-SDK: 3.0.0 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Edge MicroServer (EMS): v5.4.11 or\nlater.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\n.NET-SDK: v5.8.5 or later.\n\n\n\nFor Kepware products, the vulnerability is mitigated if the\nThingWorx Interface is not enabled. To use the ThingWorx Interface\nwithout the vulnerability, update to the latest version of the product:\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nKepware KEPServerEX: v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Server (formerly ThingWorx\nIndustrial Connectivity): v6.13 or later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nThingWorx Kepware Edge: v1.6 or later.\n\n\n\nThe following products should be upgraded as indicated or in\naccordance with the applicable organization\u2019s recommendations if the ThingWorx\nInterface is in use: \n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nRockwell Automation KEPServer Enterprise: v6.13\nor later.\n\n\n\n\u00b7 \u00a0 \u00a0 \u00a0 \u00a0\nGE Digital Industrial Gateway Server: v7.613 or\nlater.\n\n\n\nFor\nmore information see PTC\u2019s Customer Support Article\n.\n\n\n\n\n\n\n\n\n"
}
],
"source": {
"discovery": "EXTERNAL"
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:rockwellautomation:kepserver_enterprise:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.12",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:thingworx_kepware_edge:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "1.5",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:thingworx_.net-sdk:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.8.4.971",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:thingworx_edge_c-sdk:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "2.2.12.1052",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:thingworx_edge_microserver:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "5.4.10.0",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:kepware_serverex:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.12",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ge:digital_industrial_gateway_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "7.612",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:kepware_server:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndIncluding": "6.12",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:ptc:thingworx_industrial_connectivity:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2023-0754"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-190"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01",
"refsource": "MISC",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-03-03T17:41Z",
"publishedDate": "2023-02-23T22:15Z"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…