gsd-2023-31222
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-31222", "id": "GSD-2023-31222" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-31222" ], "details": "Deserialization of untrusted data\u00a0in Microsoft Messaging Queuing Service in Medtronic\u0027s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a\u00a0healthcare delivery organization\u2019s Paceart Optima system\u00a0cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration\u00a0via network connectivity.", "id": "GSD-2023-31222", "modified": "2023-12-13T01:20:29.940163Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "security@medtronic.com", "ID": "CVE-2023-31222", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "Paceart Optima ", "version": { "version_data": [ { "version_affected": "=", "version_value": "Versions 1.11 and earlier" } ] } } ] }, "vendor_name": "Medtronic" } ] } }, "credits": [ { "lang": "en", "value": "Medtronic" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Deserialization of untrusted data\u00a0in Microsoft Messaging Queuing Service in Medtronic\u0027s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a\u00a0healthcare delivery organization\u2019s Paceart Optima system\u00a0cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration\u00a0via network connectivity." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-502", "lang": "eng", "value": "CWE-502" } ] } ] }, "references": { "reference_data": [ { "name": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html", "refsource": "MISC", "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Refer to Medtronic Security Bulletin:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html\"\u003ehttps://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html\u003c/a\u003e" } ], "value": "Refer to Medtronic Security Bulletin:\u00a0 https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html " } ], "source": { "discovery": "INTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\nRefer to Medtronic Security Bulletin: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html\"\u003ehttps://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html\u003c/a\u003e\n\n\u003cbr\u003e" } ], "value": "\nRefer to Medtronic Security Bulletin: https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html \n\n\n" } ] }, "nvd.nist.gov": { "configurations": { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:medtronic:paceart_optima:*:*:*:*:*:windows:*:*", "cpe_name": [], "versionEndExcluding": "1.12", "vulnerable": true } ], "operator": "OR" } ] }, "cve": { "CVE_data_meta": { "ASSIGNER": "security@medtronic.com", "ID": "CVE-2023-31222" }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "en", "value": "Deserialization of untrusted data\u00a0in Microsoft Messaging Queuing Service in Medtronic\u0027s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a\u00a0healthcare delivery organization\u2019s Paceart Optima system\u00a0cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration\u00a0via network connectivity." } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "en", "value": "CWE-502" } ] } ] }, "references": { "reference_data": [ { "name": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html", "refsource": "MISC", "tags": [ "Mitigation", "Vendor Advisory" ], "url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html" } ] } }, "impact": { "baseMetricV3": { "cvssV3": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 8.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 5.9 } }, "lastModifiedDate": "2023-07-07T16:13Z", "publishedDate": "2023-06-29T16:15Z" } } }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.