gsd-2023-6221
Vulnerability from gsd
Modified
2023-12-13 01:20
Details
** UNSUPPPORTED WHEN ASSIGNED **
The cloud provider MachineSense uses for integration and deployment for multiple MachineSense devices, such as the programmable logic controller (PLC), PumpSense, PowerAnalyzer, FeverWarn, and others is insufficiently protected against unauthorized access. An attacker with access to the internal procedures could view source code, secret credentials, and more.
Aliases
Aliases
{ "GSD": { "alias": "CVE-2023-6221", "id": "GSD-2023-6221" }, "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2023-6221" ], "details": "** UNSUPPPORTED WHEN ASSIGNED ** \nThe cloud provider MachineSense uses for integration and deployment for multiple MachineSense devices, such as the programmable logic controller (PLC), PumpSense, PowerAnalyzer, FeverWarn, and others is insufficiently protected against unauthorized access. An attacker with access to the internal procedures could view source code, secret credentials, and more.\n\n", "id": "GSD-2023-6221", "modified": "2023-12-13T01:20:32.857366Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "ics-cert@hq.dhs.gov", "ID": "CVE-2023-6221", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FeverWarn", "version": { "version_data": [ { "version_affected": "=", "version_value": "ESP32" }, { "version_affected": "=", "version_value": "RaspberryPi" }, { "version_affected": "=", "version_value": "DataHub RaspberryPi" } ] } } ] }, "vendor_name": "MachineSense" } ] } }, "credits": [ { "lang": "en", "value": "Vera Mens of Claroty Research reported these vulnerabilities to CISA." } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "** UNSUPPPORTED WHEN ASSIGNED ** \nThe cloud provider MachineSense uses for integration and deployment for multiple MachineSense devices, such as the programmable logic controller (PLC), PumpSense, PowerAnalyzer, FeverWarn, and others is insufficiently protected against unauthorized access. An attacker with access to the internal procedures could view source code, secret credentials, and more.\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-306", "lang": "eng", "value": "CWE-306 Missing Authentication for Critical Function" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01" }, { "name": "https://machinesense.com/pages/about-machinesense", "refsource": "MISC", "url": "https://machinesense.com/pages/about-machinesense" } ] }, "source": { "discovery": "EXTERNAL" }, "work_around": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eFeverWarn and the associated cloud service were pandemic-specific products for elevated body temperature scanning, discontinued by MachineSense prior to the end of the pandemic. They are no longer available, and there will be no future availability or upgrades. MachineSense is not aware of any current users of FeverWarn. Users of the affected product are encouraged to \u003c/span\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://machinesense.com/pages/about-machinesense\"\u003econtact MachineSense\u003c/a\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;for additional information.\u003c/span\u003e\n\n\u003cbr\u003e" } ], "value": "\nFeverWarn and the associated cloud service were pandemic-specific products for elevated body temperature scanning, discontinued by MachineSense prior to the end of the pandemic. They are no longer available, and there will be no future availability or upgrades. MachineSense is not aware of any current users of FeverWarn. Users of the affected product are encouraged to contact MachineSense https://machinesense.com/pages/about-machinesense \u00a0for additional information.\n\n\n" } ] }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:machinesense:feverwarn_firmware:-:*:*:*:*:*:*:*", "matchCriteriaId": "45F21168-E7F1-49E4-84B0-0B4EB9C6DE50", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:machinesense:feverwarn:-:*:*:*:*:*:*:*", "matchCriteriaId": "489AD7C3-7648-4398-BA27-450E909171EC", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "\nThe cloud provider MachineSense uses for integration and deployment for multiple MachineSense devices, such as the programmable logic controller (PLC), PumpSense, PowerAnalyzer, FeverWarn, and others is insufficiently protected against unauthorized access. An attacker with access to the internal procedures could view source code, secret credentials, and more.\n\n" }, { "lang": "es", "value": "El proveedor de nube que MachineSense utiliza para la integraci\u00f3n y la implementaci\u00f3n de m\u00faltiples dispositivos MachineSense, como el controlador l\u00f3gico programable (PLC), PumpSense, PowerAnalyzer, FeverWarn y otros, no est\u00e1 suficientemente protegido contra el acceso no autorizado. Un atacante con acceso a los procedimientos internos podr\u00eda ver el c\u00f3digo fuente, credenciales secretas y m\u00e1s." } ], "id": "CVE-2023-6221", "lastModified": "2024-04-11T01:23:15.053", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 6.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 2.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "NONE", "baseScore": 7.7, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 3.1, "impactScore": 4.0, "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] }, "published": "2024-02-01T23:15:10.510", "references": [ { "source": "ics-cert@hq.dhs.gov", "tags": [ "Product" ], "url": "https://machinesense.com/pages/about-machinesense" }, { "source": "ics-cert@hq.dhs.gov", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-025-01" } ], "sourceIdentifier": "ics-cert@hq.dhs.gov", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-306" } ], "source": "ics-cert@hq.dhs.gov", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.