GSD-2023-6815
Vulnerability from gsd - Updated: 2023-12-14 06:01Details
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet.
Aliases
{
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-6815"
],
"details": "Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet.",
"id": "GSD-2023-6815",
"modified": "2023-12-14T06:01:34.521553Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2023-6815",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MELSEC iQ-R Series Safety CPU R08SFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series Safety CPU R16SFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series Safety CPU R32SFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series Safety CPU R120SFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series SIL2 Process CPU R16PSFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series SIL2 Process CPU R32PSFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
},
{
"product_name": "MELSEC iQ-R Series SIL2 Process CPU R120PSFCPU",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric Corporation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet."
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-266",
"lang": "eng",
"value": "CWE-266 Incorrect Privilege Assignment"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU95085830/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU95085830/index.html"
},
{
"name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-044-01"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"cve": {
"descriptions": [
{
"lang": "en",
"value": "Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet."
}
],
"id": "CVE-2023-6815",
"lastModified": "2024-02-13T14:01:07.747",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 3.6,
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Secondary"
}
]
},
"published": "2024-02-13T07:15:46.843",
"references": [
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://jvn.jp/vu/JVNVU95085830/index.html"
},
{
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-021_en.pdf"
}
],
"sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-266"
}
],
"source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"type": "Primary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…