gsd-2023-6943
Vulnerability from gsd
Modified
2023-12-21 06:01
Details
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.
Aliases



{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2023-6943"
      ],
      "details": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.",
      "id": "GSD-2023-6943",
      "modified": "2023-12-21T06:01:24.657333Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "ID": "CVE-2023-6943",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "EZSocket",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "3.0 and later"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "FR Configurator2",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "GT Designer3 Version1(GOT1000)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "GT Designer3 Version1(GOT2000)",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "GX Works2",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "1.11M and later"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "GX Works3",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MELSOFT Navigator",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "1.04E and later"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MT Works2",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all versions"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MX Component",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "4.00A and later"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "MX OPC Server DA/UA",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "all versions"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "Mitsubishi Electric Corporation"
            }
          ]
        }
      },
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-470",
                "lang": "eng",
                "value": "CWE-470 Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027)"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf",
            "refsource": "MISC",
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
          },
          {
            "name": "https://jvn.jp/vu/JVNVU95103362",
            "refsource": "MISC",
            "url": "https://jvn.jp/vu/JVNVU95103362"
          },
          {
            "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
          }
        ]
      },
      "source": {
        "discovery": "UNKNOWN"
      }
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:ezsocket:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C6096E48-9ECD-48FF-9F5E-D182E42D41C9",
                    "versionStartIncluding": "3.0",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:fr_configurator2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CED78B28-BBBF-4869-BC1C-F0789867FB4C",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:got1000:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C31EFBDE-DE71-46F3-97A1-CABC037FC31D",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:got2000:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5D887323-BBDD-41ED-82B8-66DE412666F5",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:gx_works2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B73766EB-FF3E-495E-B1C1-5D49A1569696",
                    "versionStartIncluding": "1.11m",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:gx_works3:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "F4AEDEEE-5070-41E2-B4DC-6DE8456BC028",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mc_works64:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E5790F2E-5511-46F6-94E5-F3E1A2367662",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:melsoft_navigator:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5F3C096D-D510-46F4-B46A-A234CA630227",
                    "versionStartIncluding": "1.04e",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mt_works2:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0EC0ACF4-C303-4EC0-A755-1F9AE4152DDB",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:mitsubishielectric:mx_component:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "407781DB-9AF9-4E3A-BF24-1787ADB33F42",
                    "versionStartIncluding": "4.00a",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "Use of Externally-Controlled Input to Select Classes or Code (\u0027Unsafe Reflection\u0027) vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 and later, FR Configurator2 all versions, GT Designer3 Version1(GOT1000) all versions, GT Designer3 Version1(GOT2000) all versions, GX Works2 versions 1.11M and later, GX Works3 all versions, MELSOFT Navigator versions 1.04E and later, MT Works2 all versions, MX Component versions 4.00A and later and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products."
          },
          {
            "lang": "es",
            "value": "Vulnerabilidad de uso de entrada controlada externamente para seleccionar clases o c\u00f3digo (\"Reflexi\u00f3n insegura\") en Mitsubishi Electric Corporation EZSocket versiones 3.0 y posteriores, FR Configurator2 todas las versiones, GT Designer3 Versi\u00f3n1(GOT1000) todas las versiones, GT Designer3 Versi\u00f3n1(GOT2000) todas las versiones , GX Works2 versiones 1.11M y posteriores, GX Works3 todas las versiones, MELSOFT Navigator versiones 1.04E y posteriores, MT Works2 todas las versiones, MX Component versiones 4.00A y posteriores y MX OPC Server DA/UA todas las versiones permiten que un atacante remoto no autenticado ejecute un c\u00f3digo malicioso por RPC con una ruta a una librer\u00eda maliciosa mientras est\u00e1 conectado a los productos."
          }
        ],
        "id": "CVE-2023-6943",
        "lastModified": "2024-02-08T16:41:51.857",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-01-30T09:15:47.960",
        "references": [
          {
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://jvn.jp/vu/JVNVU95103362"
          },
          {
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-030-02"
          },
          {
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-020_en.pdf"
          }
        ],
        "sourceIdentifier": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-470"
              }
            ],
            "source": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
            "type": "Primary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.