gsd-2024-0242
Vulnerability from gsd
Modified
2024-01-05 06:02
Details
Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-0242" ], "details": "Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings.", "id": "GSD-2024-0242", "modified": "2024-01-05T06:02:19.764852Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "productsecurity@jci.com", "ID": "CVE-2024-0242", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "IQ Panel 4", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "4.4.2" } ] } }, { "product_name": "IQ4 Hub", "version": { "version_data": [ { "version_affected": "\u003c", "version_name": "0", "version_value": "4.4.2" } ] } } ] }, "vendor_name": "Qolsys, Inc." } ] } }, "credits": [ { "lang": "en", "value": "Cody Jung" } ], "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings." } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "cweId": "CWE-200", "lang": "eng", "value": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories", "refsource": "MISC", "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" }, { "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-039-01", "refsource": "MISC", "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-039-01" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Upgrade IQ Panel 4 to version 4.4.2.\u003cbr\u003e" } ], "value": "Upgrade IQ Panel 4 to version 4.4.2.\n" }, { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "Upgrade IQ4 Hub to version 4.4.2.\u003cbr\u003e" } ], "value": "Upgrade IQ4 Hub to version 4.4.2.\n" }, { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The firmware can be updated remotely to all available devices in the field.\u003cbr\u003e" } ], "value": "The firmware can be updated remotely to all available devices in the field.\n" }, { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "The firmware update can also be manually loaded by applying the patch tag \u201ciqpanel4.4.2\u201d on the device after navigating to its firmware update page.\u003cbr\u003e" } ], "value": "The firmware update can also be manually loaded by applying the patch tag \u201ciqpanel4.4.2\u201d on the device after navigating to its firmware update page.\n" } ], "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "cve": { "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:johnsoncontrols:qolsys_iq_panel_4_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "A1D873CB-3A82-4BEA-AEAB-E815EB0CA24E", "versionEndExcluding": "4.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:johnsoncontrols:qolsys_iq_panel_4:-:*:*:*:*:*:*:*", "matchCriteriaId": "AB88A6F4-3534-4684-8C56-5AC9D1BF7C0E", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" }, { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:johnsoncontrols:qolsys_iq4_hub_firmware:*:*:*:*:*:*:*:*", "matchCriteriaId": "B449AC3F-4ACC-4D9A-A6B2-B4B4682E7335", "versionEndExcluding": "4.4.2", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:johnsoncontrols:qolsys_iq4_hub:-:*:*:*:*:*:*:*", "matchCriteriaId": "1F577B88-3EB5-43E3-9F88-C84E81A6D99A", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "descriptions": [ { "lang": "en", "value": "Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings." }, { "lang": "es", "value": "En determinadas circunstancias, el software del panel IQ Panel4 e IQ4 Hub anterior a la versi\u00f3n 4.4.2 podr\u00eda permitir el acceso no autorizado a la configuraci\u00f3n." } ], "id": "CVE-2024-0242", "lastModified": "2024-02-15T19:08:40.337", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "HIGH", "baseScore": 9.8, "baseSeverity": "CRITICAL", "confidentialityImpact": "HIGH", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 5.9, "source": "nvd@nist.gov", "type": "Primary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "PHYSICAL", "availabilityImpact": "HIGH", "baseScore": 7.3, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:H", "version": "3.1" }, "exploitabilityScore": 0.9, "impactScore": 5.8, "source": "productsecurity@jci.com", "type": "Secondary" } ] }, "published": "2024-02-08T20:15:52.407", "references": [ { "source": "productsecurity@jci.com", "tags": [ "Third Party Advisory", "US Government Resource" ], "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-039-01" }, { "source": "productsecurity@jci.com", "tags": [ "Product" ], "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories" } ], "sourceIdentifier": "productsecurity@jci.com", "vulnStatus": "Analyzed", "weaknesses": [ { "description": [ { "lang": "en", "value": "NVD-CWE-noinfo" } ], "source": "nvd@nist.gov", "type": "Primary" }, { "description": [ { "lang": "en", "value": "CWE-200" } ], "source": "productsecurity@jci.com", "type": "Secondary" } ] } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.