gsd-2024-21914
Vulnerability from gsd
Modified
2024-01-04 06:02
Details
A vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView™ Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView™ product.
Aliases
{ "gsd": { "metadata": { "exploitCode": "unknown", "remediation": "unknown", "reportConfidence": "confirmed", "type": "vulnerability" }, "osvSchema": { "aliases": [ "CVE-2024-21914" ], "details": "\nA vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView\u2122 Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView\u2122 product.\n\n", "id": "GSD-2024-21914", "modified": "2024-01-04T06:02:16.227262Z", "schema_version": "1.4.0" } }, "namespaces": { "cve.org": { "CVE_data_meta": { "ASSIGNER": "PSIRT@rockwellautomation.com", "ID": "CVE-2024-21914", "STATE": "PUBLIC" }, "affects": { "vendor": { "vendor_data": [ { "product": { "product_data": [ { "product_name": "FactoryTalk\u00ae View ME", "version": { "version_data": [ { "version_affected": "=", "version_value": "\u003cv14" } ] } } ] }, "vendor_name": "Rockwell Automation" } ] } }, "data_format": "MITRE", "data_type": "CVE", "data_version": "4.0", "description": { "description_data": [ { "lang": "eng", "value": "\nA vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView\u2122 Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView\u2122 product.\n\n" } ] }, "generator": { "engine": "Vulnogram 0.1.0-dev" }, "impact": { "cvss": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" } ] }, "problemtype": { "problemtype_data": [ { "description": [ { "lang": "eng", "value": " Improper security protection for remote restart action" } ] } ] }, "references": { "reference_data": [ { "name": "https://www.rockwellautomation.com/en-us/support/advisory.SD1663.html", "refsource": "MISC", "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1663.html" } ] }, "solution": [ { "lang": "en", "supportingMedia": [ { "base64": false, "type": "text/html", "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUsers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible. \u0026nbsp;\u003cbr\u003e\u003c/span\u003e\n\n\u003cul\u003e\u003cli\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\"\u003eSecurity Best Practices\u003c/a\u003e\u003c/li\u003e\u003c/ul\u003e" } ], "value": "\nUsers using the affected software, who are not able to upgrade to one of the corrected versions, are encouraged to apply security best practices, where possible. \u00a0\n\n * Security Best Practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight \n\n" } ], "source": { "discovery": "UNKNOWN" } }, "nvd.nist.gov": { "cve": { "descriptions": [ { "lang": "en", "value": "\nA vulnerability exists in the affected product that allows a malicious user to restart the Rockwell Automation PanelView\u2122 Plus 7 terminal remotely without security protections. If the vulnerability is exploited, it could lead to the loss of view or control of the PanelView\u2122 product.\n\n" }, { "lang": "es", "value": "Existe una vulnerabilidad en el producto afectado que permite a un usuario malintencionado reiniciar el terminal Rockwell Automation PanelView\u2122 Plus 7 de forma remota sin protecciones de seguridad. Si se explota la vulnerabilidad, podr\u00eda provocar la p\u00e9rdida de visi\u00f3n o control del producto PanelView\u2122." } ], "id": "CVE-2024-21914", "lastModified": "2024-03-26T12:55:05.010", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "NETWORK", "availabilityImpact": "LOW", "baseScore": 5.3, "baseSeverity": "MEDIUM", "confidentialityImpact": "NONE", "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L", "version": "3.1" }, "exploitabilityScore": 3.9, "impactScore": 1.4, "source": "PSIRT@rockwellautomation.com", "type": "Secondary" } ] }, "published": "2024-03-25T22:37:19.627", "references": [ { "source": "PSIRT@rockwellautomation.com", "url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1663.html" } ], "sourceIdentifier": "PSIRT@rockwellautomation.com", "vulnStatus": "Awaiting Analysis" } } } }
Loading...
Loading...
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.