GSD-2024-21916
Vulnerability from gsd - Updated: 2024-01-04 06:02Details
A denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.
Aliases
{
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2024-21916"
],
"details": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF.",
"id": "GSD-2024-21916",
"modified": "2024-01-04T06:02:16.117754Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@rockwellautomation.com",
"ID": "CVE-2024-21916",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ControlLogix\u00ae 5570",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "20.011"
}
]
}
},
{
"product_name": "GuardLogix\u00ae 5570",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "20.011"
}
]
}
},
{
"product_name": "ControlLogix\u00ae 5570 redundant",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "20.054_kit1"
}
]
}
}
]
},
"vendor_name": "Rockwell Automation"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF."
}
]
},
"generator": {
"engine": "Vulnogram 0.1.0-dev"
},
"impact": {
"cvss": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-119",
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html",
"refsource": "MISC",
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
}
]
},
"solution": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\n\u003cul\u003e\u003cli\u003eUpdate to corrected Firmware.\u0026nbsp;\u003c/li\u003e\u003c/ul\u003e\n\n\u003ctable\u003e\u003ctbody\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eAffected Product\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\"\u003eFirst Known in Firmware\u003c/a\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003eCorrected in Firmware\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eGuardLogix\u00ae 5570\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.011\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.016, 34.013, 35.012, 36.011 and later\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003ctr\u003e\u003ctd\u003e\u003cp\u003eControlLogix\u00ae 5570 redundant\u003cb\u003e\u003c/b\u003e\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003e20.054_kit1\u003c/p\u003e\u003c/td\u003e\u003ctd\u003e\u003cp\u003ev33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\u003c/p\u003e\u003c/td\u003e\u003c/tr\u003e\u003c/tbody\u003e\u003c/table\u003e\n\n\u003cbr\u003e\n\n"
}
],
"value": "\n * Update to corrected Firmware.\u00a0\n\n\n\n\nAffected Product\n\nFirst Known in Firmware\n\nCorrected in Firmware\n\nControlLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nGuardLogix\u00ae 5570\n\n20.011\n\nv33.016, 34.013, 35.012, 36.011 and later\n\nControlLogix\u00ae 5570 redundant\n\n20.054_kit1\n\nv33.053_kit1, 34.052_kit1, 35.052_kit1, 36.051_kit1 and late\n\n\n\n\n\n\n"
}
],
"source": {
"discovery": "UNKNOWN"
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:controllogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*",
"matchCriteriaId": "06E12A7B-E32C-46DE-891B-B42586053A33",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:controllogix_5570_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C16C24E2-4CB6-4413-8D48-588E0246617E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:guardlogix_5570_controller_firmware:20.011:*:*:*:*:*:*:*",
"matchCriteriaId": "6D5A9D00-9B54-4A85-9E9D-652FA0BC911F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:guardlogix_5570_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B4B273FA-0865-4505-AAF8-1676940A3EA9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:rockwellautomation:controllogix_5570_redundant_controller_firmware:20.054_kit1:*:*:*:*:*:*:*",
"matchCriteriaId": "9CA7904D-3C8B-4CED-B2AB-0CCD266B148F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:rockwellautomation:controllogix_5570_redundant_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "898183DD-C3AE-42EE-9891-81BFA774476A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "\nA denial-of-service vulnerability exists in specific Rockwell Automation ControlLogix ang GuardLogix controllers. If exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart itself to recover from the MNRF."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de denegaci\u00f3n de servicio en controladores Rockwell Automation ControlLogix ang GuardLogix. Si se explota, el producto podr\u00eda experimentar un fallo importante no recuperable (MNRF). El dispositivo se reiniciar\u00e1 solo para recuperarse del MNRF."
}
],
"id": "CVE-2024-21916",
"lastModified": "2024-02-08T01:34:49.067",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 4.0,
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
},
"published": "2024-01-31T19:15:08.427",
"references": [
{
"source": "PSIRT@rockwellautomation.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.rockwellautomation.com/en-us/support/advisory.SD1661.html"
}
],
"sourceIdentifier": "PSIRT@rockwellautomation.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "PSIRT@rockwellautomation.com",
"type": "Secondary"
}
]
}
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…