gsd-2024-22388
Vulnerability from gsd
Modified
2024-01-26 06:02
Details
Certain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys.
Aliases



{
  "gsd": {
    "metadata": {
      "exploitCode": "unknown",
      "remediation": "unknown",
      "reportConfidence": "confirmed",
      "type": "vulnerability"
    },
    "osvSchema": {
      "aliases": [
        "CVE-2024-22388"
      ],
      "details": "\nCertain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys.\n\n",
      "id": "GSD-2024-22388",
      "modified": "2024-01-26T06:02:25.293863Z",
      "schema_version": "1.4.0"
    }
  },
  "namespaces": {
    "cve.org": {
      "CVE_data_meta": {
        "ASSIGNER": "ics-cert@hq.dhs.gov",
        "ID": "CVE-2024-22388",
        "STATE": "PUBLIC"
      },
      "affects": {
        "vendor": {
          "vendor_data": [
            {
              "product": {
                "product_data": [
                  {
                    "product_name": "iCLASS SE CP1000 Encoder",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "iCLASS SE Readers",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "iCLASS SE Reader Modules",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "iCLASS SE Processors",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "OMNIKEY 5427CK Readers",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "OMNIKEY 5127CK Readers",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "OMNIKEY 5023 Readers",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  },
                  {
                    "product_name": "OMNIKEY 5027 Readers",
                    "version": {
                      "version_data": [
                        {
                          "version_affected": "=",
                          "version_value": "All"
                        }
                      ]
                    }
                  }
                ]
              },
              "vendor_name": "HID Global"
            }
          ]
        }
      },
      "credits": [
        {
          "lang": "en",
          "value": "HID Global reported this vulnerability to CISA."
        }
      ],
      "data_format": "MITRE",
      "data_type": "CVE",
      "data_version": "4.0",
      "description": {
        "description_data": [
          {
            "lang": "eng",
            "value": "\nCertain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys.\n\n"
          }
        ]
      },
      "generator": {
        "engine": "Vulnogram 0.1.0-dev"
      },
      "impact": {
        "cvss": [
          {
            "attackComplexity": "HIGH",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
            "version": "3.1"
          }
        ]
      },
      "problemtype": {
        "problemtype_data": [
          {
            "description": [
              {
                "cweId": "CWE-285",
                "lang": "eng",
                "value": "CWE-285 Improper Authorization"
              }
            ]
          }
        ]
      },
      "references": {
        "reference_data": [
          {
            "name": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-037-01",
            "refsource": "MISC",
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-037-01"
          },
          {
            "name": "https://support.hidglobal.com/",
            "refsource": "MISC",
            "url": "https://support.hidglobal.com/"
          }
        ]
      },
      "source": {
        "advisory": "ICSA-24-037-01",
        "discovery": "INTERNAL"
      },
      "work_around": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eHID advises users to take the following steps to mitigate these threats.\u003c/p\u003e\u003cp\u003eProtect your reader configuration cards.\u003c/p\u003e\u003cul\u003e\u003cli\u003eA malicious encoder or reader must be physically close to the reader configuration cards to communicate with them and extract information. Elite Key and Custom Key users that have kept their configuration cards secure should continue to be vigilant and restrict access to those cards.\u003cbr\u003eHID standard key users and other users who are concerned their keys may be compromised should consider steps to update the readers and credentials with new keys. To assist in this effort, HID will be introducing a free upgrade to the Elite Key program. Contact your HID representative for more information.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eProtect your credentials and disable legacy technologies.\u003c/p\u003e\u003cul\u003e\u003cli\u003eReading the PACS data from a credential is not enough to clone the credential for modern technologies like Seos and DESFire. These technologies use a credential key for authentication. However, if a system\u0027s readers still support legacy technologies (i.e., HID Prox, MiFARE Classic, etc.), then it may be possible to insert the credential information into a legacy technology credential that would be accepted by those readers. Users are encouraged to disable legacy credential technologies in their readers.\u003cbr\u003eFurther, physical credentials should always be kept safe by their users, and site managers should remind their users to be vigilant with their credentials and report missing or stolen cards.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eHarden your iCLASS SE Readers from configuration changes\u003c/p\u003e\u003cul\u003e\u003cli\u003eiCLASS SE Readers using firmware firmware version 8.6.04 or higher can use the HID Reader Manager application to prevent the readers from accepting configuration changes from configuration cards. After this is complete, users may then securely destroy their reader configuration cards.\u003cbr\u003eIf you need assistance, or if the reader firmware has not been updated to 8.6.04 or higher, contact HID Technical Support.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eHarden your HID OMNIKEY Readers, HID iCLASS SE Reader Modules, HID iCLASS SE Processors from configuration changes\u003c/p\u003e\u003cul\u003e\u003cli\u003eContact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.hidglobal.com/support\"\u003eHID\u003c/a\u003e\u0026nbsp;to receive a \"Shield Card\" that will prevent further configuration changes using reader configuration cards. After this is complete, users may then securely destroy their reader configuration cards.\u003c/li\u003e\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nHID advises users to take the following steps to mitigate these threats.\n\nProtect your reader configuration cards.\n\n  *  A malicious encoder or reader must be physically close to the reader configuration cards to communicate with them and extract information. Elite Key and Custom Key users that have kept their configuration cards secure should continue to be vigilant and restrict access to those cards.\nHID standard key users and other users who are concerned their keys may be compromised should consider steps to update the readers and credentials with new keys. To assist in this effort, HID will be introducing a free upgrade to the Elite Key program. Contact your HID representative for more information.\n\n\nProtect your credentials and disable legacy technologies.\n\n  *  Reading the PACS data from a credential is not enough to clone the credential for modern technologies like Seos and DESFire. These technologies use a credential key for authentication. However, if a system\u0027s readers still support legacy technologies (i.e., HID Prox, MiFARE Classic, etc.), then it may be possible to insert the credential information into a legacy technology credential that would be accepted by those readers. Users are encouraged to disable legacy credential technologies in their readers.\nFurther, physical credentials should always be kept safe by their users, and site managers should remind their users to be vigilant with their credentials and report missing or stolen cards.\n\n\nHarden your iCLASS SE Readers from configuration changes\n\n  *  iCLASS SE Readers using firmware firmware version 8.6.04 or higher can use the HID Reader Manager application to prevent the readers from accepting configuration changes from configuration cards. After this is complete, users may then securely destroy their reader configuration cards.\nIf you need assistance, or if the reader firmware has not been updated to 8.6.04 or higher, contact HID Technical Support.\n\n\nHarden your HID OMNIKEY Readers, HID iCLASS SE Reader Modules, HID iCLASS SE Processors from configuration changes\n\n  *  Contact  HID https://www.hidglobal.com/support \u00a0to receive a \"Shield Card\" that will prevent further configuration changes using reader configuration cards. After this is complete, users may then securely destroy their reader configuration cards.\n\n\n\n\n\n"
        }
      ]
    },
    "nvd.nist.gov": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:iclass_se_cp1000_encoder_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BA7199D9-8A09-4ABF-926C-BF4739222282",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:iclass_se_cp1000_encoder:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2BB854B8-F5E0-4A00-922C-5B62564DB158",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:iclass_se_readers_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2F84C363-45B4-40F9-8C8F-93394F2AF318",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:iclass_se_readers:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "08AA1F70-0EDD-498D-A60A-D7E769765A1B",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:iclass_se_reader_modules_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8B5F3AFC-7213-41E7-800A-78BE8CA53515",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:iclass_se_reader_modules:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "70B620F5-3B4E-4728-9066-506105282B91",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:iclass_se_processors_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "95FA7393-0EF9-43A4-9F26-DB48FDC3DAE7",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:iclass_se_processors:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "029F78BB-6EFE-4CD1-80F3-2B5D476D049C",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:omnikey_5427ck_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "70382765-8BA5-4114-9681-BC4118FD6E24",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:omnikey_5427ck:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "095B970F-BDB3-449D-8859-ED942B68EC99",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:omnikey_5127ck_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "3AD6E73F-E3CA-412B-986F-8582269C2FC1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:omnikey_5127ck:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FDB1E42B-DDCE-4333-B9A3-56E046988E40",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:omnikey_5023_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "CE9661B3-E09D-4A88-AB61-C68E3EC7024C",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:omnikey_5023:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "BA7B4826-9C1C-4685-AD9A-B2A89069A03F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:hidglobal:omnikey_5027_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "1833B4BD-0205-412A-BDEE-FE993620C941",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:hidglobal:omnikey_5027:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "71567BE0-8B74-4AF2-840C-E52A31A95BC2",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "descriptions": [
          {
            "lang": "en",
            "value": "\nCertain configuration available in the communication channel for encoders could expose sensitive data when reader configuration cards are programmed. This data could include credential and device administration keys.\n\n"
          },
          {
            "lang": "es",
            "value": "Cierta configuraci\u00f3n disponible en el canal de comunicaci\u00f3n para codificadores podr\u00eda exponer datos confidenciales cuando se programan las tarjetas de configuraci\u00f3n del lector. Estos datos podr\u00edan incluir claves de administraci\u00f3n de dispositivos y credenciales."
          }
        ],
        "id": "CVE-2024-22388",
        "lastModified": "2024-02-14T20:59:09.660",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "HIGH",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.9,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 1.4,
              "impactScore": 4.0,
              "source": "ics-cert@hq.dhs.gov",
              "type": "Secondary"
            }
          ]
        },
        "published": "2024-02-06T23:15:08.707",
        "references": [
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Product"
            ],
            "url": "https://support.hidglobal.com/"
          },
          {
            "source": "ics-cert@hq.dhs.gov",
            "tags": [
              "Third Party Advisory",
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-037-01"
          }
        ],
        "sourceIdentifier": "ics-cert@hq.dhs.gov",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-Other"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-285"
              }
            ],
            "source": "ics-cert@hq.dhs.gov",
            "type": "Secondary"
          }
        ]
      }
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.