var-201702-0119
Vulnerability from variot
An improper certificate validation vulnerability in Fortinet FortiManager 5.0.6 through 5.2.7 and 5.4.0 through 5.4.1 allows remote attacker to spoof a trusted entity by using a man-in-the-middle (MITM) attack via the Fortisandbox devices probing feature. FortiManager is prone to an information-disclosure vulnerability. An attacker can exploit this issue to obtain potentially sensitive information. Information obtained may aid in further attacks. FortiManager 5.0.6 through 5.2.7 and 5.4.0 through 5.4.1 are vulnerable. Fortinet FortiManager is a centralized network security management platform developed by Fortinet. The platform supports centralized management of any number of Fortinet devices, and can group devices into different management domains (ADOMs) to further simplify multi-device security deployment and management. A security vulnerability exists in Fortinet FortiManager due to the program not properly validating TLS certificates
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201702-0119", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "fortimanager", "scope": "eq", "trust": 1.9, "vendor": "fortinet", "version": "5.4.1" }, { "model": "fortimanager", "scope": "eq", "trust": 1.9, "vendor": "fortinet", "version": "5.0.9" }, { "model": "fortimanager", "scope": "eq", "trust": 1.9, "vendor": "fortinet", "version": "5.0.8" }, { "model": "fortimanager", "scope": "eq", "trust": 1.9, "vendor": "fortinet", "version": "5.0.7" }, { "model": "fortimanager", "scope": "eq", "trust": 1.9, "vendor": "fortinet", "version": "5.0.6" }, { "model": "fortimanager", "scope": "eq", "trust": 1.6, "vendor": "fortinet", "version": "5.4.0" }, { "model": "fortimanager", "scope": "eq", "trust": 1.6, "vendor": "fortinet", "version": "5.0.5" }, { "model": "fortimanager", "scope": "eq", "trust": 1.6, "vendor": "fortinet", "version": "5.0.4" }, { "model": "fortimanager", "scope": "eq", "trust": 1.6, "vendor": "fortinet", "version": "5.0.10" }, { "model": "fortimanager", "scope": "eq", "trust": 1.6, "vendor": "fortinet", "version": "5.0.3" }, { "model": "fortimanager", "scope": "eq", "trust": 1.3, "vendor": "fortinet", "version": "5.2.7" }, { "model": "fortimanager", "scope": "eq", "trust": 1.3, "vendor": "fortinet", "version": "5.2.6" }, { "model": "fortimanager", "scope": "eq", "trust": 1.3, "vendor": "fortinet", "version": "5.2.2" }, { "model": "fortimanager", "scope": "eq", "trust": 1.3, "vendor": "fortinet", "version": "5.2.1" }, { "model": "fortimanager", "scope": "eq", "trust": 1.3, "vendor": "fortinet", "version": "5.2.4" }, { "model": "fortimanager", "scope": "eq", "trust": 1.3, "vendor": "fortinet", "version": "5.2.3" }, { "model": "fortimanager", "scope": "eq", "trust": 1.0, "vendor": "fortinet", "version": "5.0.11" }, { "model": "fortimanager", "scope": "eq", "trust": 1.0, "vendor": "fortinet", "version": "5.2.0" }, { "model": "fortimanager", "scope": "eq", "trust": 0.8, "vendor": "fortinet", "version": "5.0.6 to 5.2.7" }, { "model": "fortimanager", "scope": "eq", "trust": 0.8, "vendor": "fortinet", "version": "5.4.0 to 5.4.1" }, { "model": "fortimanager", "scope": "eq", "trust": 0.3, "vendor": "fortinet", "version": "5.4" }, { "model": "fortimanager", "scope": "eq", "trust": 0.3, "vendor": "fortinet", "version": "5.2.5" }, { "model": "fortimanager", "scope": "ne", "trust": 0.3, "vendor": "fortinet", "version": "5.4.2" }, { "model": "fortimanager", "scope": "ne", "trust": 0.3, "vendor": "fortinet", "version": "5.2.8" } ], "sources": [ { "db": "BID", "id": "96157" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "NVD", "id": "CVE-2016-8495" }, { "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.11:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.10:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.2:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.3:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.5:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.8:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.9:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.4:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.2.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.6:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.0.7:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.4.1:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:fortinet:fortimanager_firmware:5.4.0:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2016-8495" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "AirBus security team", "sources": [ { "db": "BID", "id": "96157" } ], "trust": 0.3 }, "cve": "CVE-2016-8495", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "impactScore": 4.9, "integrityImpact": "PARTIAL", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "MEDIUM", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Medium", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "None", "baseScore": 5.8, "confidentialityImpact": "Partial", "exploitabilityScore": null, "id": "CVE-2016-8495", "impactScore": null, "integrityImpact": "Partial", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "Medium", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:N", "version": "2.0" }, { "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "NONE", "baseScore": 5.8, "confidentialityImpact": "PARTIAL", "exploitabilityScore": 8.6, "id": "VHN-97315", "impactScore": 4.9, "integrityImpact": "PARTIAL", "severity": "MEDIUM", "trust": 0.1, "vectorString": "AV:N/AC:M/AU:N/C:P/I:P/A:N", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "HIGH", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 2.2, "impactScore": 5.2, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" }, { "attackComplexity": "High", "attackVector": "Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.4, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2016-8495", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2016-8495", "trust": 1.8, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201702-474", "trust": 0.6, "value": "MEDIUM" }, { "author": "VULHUB", "id": "VHN-97315", "trust": 0.1, "value": "MEDIUM" } ] } ], "sources": [ { "db": "VULHUB", "id": "VHN-97315" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "NVD", "id": "CVE-2016-8495" }, { "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "An improper certificate validation vulnerability in Fortinet FortiManager 5.0.6 through 5.2.7 and 5.4.0 through 5.4.1 allows remote attacker to spoof a trusted entity by using a man-in-the-middle (MITM) attack via the Fortisandbox devices probing feature. FortiManager is prone to an information-disclosure vulnerability. \nAn attacker can exploit this issue to obtain potentially sensitive information. Information obtained may aid in further attacks. \nFortiManager 5.0.6 through 5.2.7 and 5.4.0 through 5.4.1 are vulnerable. Fortinet FortiManager is a centralized network security management platform developed by Fortinet. The platform supports centralized management of any number of Fortinet devices, and can group devices into different management domains (ADOMs) to further simplify multi-device security deployment and management. A security vulnerability exists in Fortinet FortiManager due to the program not properly validating TLS certificates", "sources": [ { "db": "NVD", "id": "CVE-2016-8495" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "BID", "id": "96157" }, { "db": "VULHUB", "id": "VHN-97315" } ], "trust": 1.98 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2016-8495", "trust": 2.8 }, { "db": "BID", "id": "96157", "trust": 1.4 }, { "db": "SECTRACK", "id": "1037805", "trust": 1.1 }, { "db": "JVNDB", "id": "JVNDB-2016-007804", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-201702-474", "trust": 0.7 }, { "db": "VULHUB", "id": "VHN-97315", "trust": 0.1 } ], "sources": [ { "db": "VULHUB", "id": "VHN-97315" }, { "db": "BID", "id": "96157" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "NVD", "id": "CVE-2016-8495" }, { "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "id": "VAR-201702-0119", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VULHUB", "id": "VHN-97315" } ], "trust": 0.01 }, "last_update_date": "2023-12-18T12:04:41.214000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "FortiManager TLS certificate validation failure", "trust": 0.8, "url": "https://fortiguard.com/advisory/fg-ir-16-055" }, { "title": "Fortinet FortiManager Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=67763" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-200", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-97315" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "NVD", "id": "CVE-2016-8495" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.0, "url": "https://fortiguard.com/advisory/fg-ir-16-055" }, { "trust": 1.1, "url": "http://www.securityfocus.com/bid/96157" }, { "trust": 1.1, "url": "http://www.securitytracker.com/id/1037805" }, { "trust": 0.8, "url": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2016-8495" }, { "trust": 0.8, "url": "http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2016-8495" }, { "trust": 0.3, "url": "http://www.fortinet.com/products/fortimanager/" }, { "trust": 0.3, "url": "http://www.fortinet.com/" } ], "sources": [ { "db": "VULHUB", "id": "VHN-97315" }, { "db": "BID", "id": "96157" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "NVD", "id": "CVE-2016-8495" }, { "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULHUB", "id": "VHN-97315" }, { "db": "BID", "id": "96157" }, { "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "db": "NVD", "id": "CVE-2016-8495" }, { "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-02-13T00:00:00", "db": "VULHUB", "id": "VHN-97315" }, { "date": "2017-02-08T00:00:00", "db": "BID", "id": "96157" }, { "date": "2017-03-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "date": "2017-02-13T15:59:00.167000", "db": "NVD", "id": "CVE-2016-8495" }, { "date": "2017-02-14T00:00:00", "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2017-07-25T00:00:00", "db": "VULHUB", "id": "VHN-97315" }, { "date": "2017-03-07T10:02:00", "db": "BID", "id": "96157" }, { "date": "2017-03-17T00:00:00", "db": "JVNDB", "id": "JVNDB-2016-007804" }, { "date": "2017-07-25T01:29:03.357000", "db": "NVD", "id": "CVE-2016-8495" }, { "date": "2017-02-14T00:00:00", "db": "CNNVD", "id": "CNNVD-201702-474" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201702-474" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Fortinet FortiManager Vulnerabilities in authentication information incomplete", "sources": [ { "db": "JVNDB", "id": "JVNDB-2016-007804" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "information disclosure", "sources": [ { "db": "CNNVD", "id": "CNNVD-201702-474" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.