A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions < V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions < V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions < V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions < V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. plural Siemens There is an input validation vulnerability in the product firmware.Service operation interruption (DoS) There is a possibility of being put into a state. The Siemens EN100 Ethernet Communication Module and SIPROTEC 5 relays are products of Siemens AG, Germany. The Siemens EN100 Ethernet Communication Module is an Ethernet module. SIPROTEC 5 relays are a relay. A denial of service vulnerability exists in the Siemens EN100 Ethernet Communication Module and SIPROTEC 5 relays. Attackers can exploit these issues to crash the affected application or consume excess memory, denying service to legitimate users
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-201807-1340", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "profinet io", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "modbus tcp", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "iec104", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "cp200", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "dnp3 tcp", "scope": "eq", "trust": 1.6, "vendor": "siemens", "version": null }, { "model": "iec 61850", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "4.33" }, { "model": "cp100", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.80" }, { "model": "cp300", "scope": "lt", "trust": 1.0, "vendor": "siemens", "version": "7.80" }, { "model": "cp100", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "cp200", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "cp300", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "en100 ethernet module dnp3", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "en100 ethernet module iec 104", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "en100 ethernet module iec 61850", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "en100 ethernet module modbus tcp", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "en100 ethernet module profinet io", "scope": null, "trust": 0.8, "vendor": "siemens", "version": null }, { "model": "variant iec for en100 ethernet module", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "61850\u003cv4.33" }, { "model": "variant profinet io for en100 ether- net module", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "variant modbus tcp for en100 ether- net module", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "variant dnp3 tcp for en100 ethernet module", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "variant iec104 for en100 ethernet module", "scope": null, "trust": 0.6, "vendor": "siemens", "version": null }, { "model": "siprotec relays with cpu variants cp300 and cp100 and the respective ethernet commu- nication modules", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "5\u003cv7.80" }, { "model": "siprotec relays with cpu variants cp200 and the respective ethernet communication mod- ules", "scope": "eq", "trust": 0.6, "vendor": "siemens", "version": "5\u003cv7.58" }, { "model": "siprotec", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "50" }, { "model": "profinet io for en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "modbus tcp for en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "iec104 for en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "0" }, { "model": "iec for en100", "scope": "eq", "trust": 0.3, "vendor": "siemens", "version": "618500" }, { "model": "siprotec cp300", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "57.80" }, { "model": "siprotec cp200", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "57.58" }, { "model": "siprotec cp100", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "57.80" }, { "model": "iec for en100", "scope": "ne", "trust": 0.3, "vendor": "siemens", "version": "618504.33" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "dnp3 tcp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "iec104", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "iec 61850", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "modbus tcp", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "profinet io", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp100", "version": "*" }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp200", "version": null }, { "model": null, "scope": "eq", "trust": 0.2, "vendor": "cp300", "version": "*" } ], "sources": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "BID", "id": "106221" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "NVD", "id": "CVE-2018-11451" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:dnp3_tcp_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:modbus_tcp_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:profinet_io_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:iec_61850_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "4.33", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:iec104_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:en100:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:siemens:cp100_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.80", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:cp300_firmware:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "7.80", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:o:siemens:cp200_firmware:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:siemens:6md86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7ss85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7ke85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sa86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sd82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sj82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sj85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sd87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sl87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sl86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sj86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7ut86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7ut87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7um85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sa87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sd86:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sl82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7ut82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7ut85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:6md85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7vk87:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sa82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sk82:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:siemens:7sk85:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2018-11451" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Victor Nikitin, and Ilya Karpov from ScadaX, Vladislav Suchkov", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1730" } ], "trust": 0.6 }, "cve": "CVE-2018-11451", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "impactScore": 6.9, "integrityImpact": "NONE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "acInsufInfo": null, "accessComplexity": "Low", "accessVector": "Network", "authentication": "None", "author": "NVD", "availabilityImpact": "Complete", "baseScore": 7.8, "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2018-11451", "impactScore": null, "integrityImpact": "None", "obtainAllPrivilege": null, "obtainOtherPrivilege": null, "obtainUserPrivilege": null, "severity": "High", "trust": 0.8, "userInteractionRequired": null, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "CNVD-2018-25425", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.0" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "IVD", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "7d828321-463f-11e9-bc16-000c29342cb1", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.2, "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C", "version": "2.9 [IVD]" }, { "accessComplexity": "LOW", "accessVector": "NETWORK", "authentication": "NONE", "author": "VULHUB", "availabilityImpact": "COMPLETE", "baseScore": 7.8, "confidentialityImpact": "NONE", "exploitabilityScore": 10.0, "id": "VHN-121312", "impactScore": 6.9, "integrityImpact": "NONE", "severity": "HIGH", "trust": 0.1, "vectorString": "AV:N/AC:L/AU:N/C:N/I:N/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "NETWORK", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.5, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 3.9, "impactScore": 3.6, "integrityImpact": "NONE", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" }, { "attackComplexity": "Low", "attackVector": "Network", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.5, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2018-11451", "impactScore": null, "integrityImpact": "None", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2018-11451", "trust": 1.8, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2018-25425", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-201807-1730", "trust": 0.6, "value": "HIGH" }, { "author": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1", "trust": 0.2, "value": "HIGH" }, { "author": "VULHUB", "id": "VHN-121312", "trust": 0.1, "value": "HIGH" } ] } ], "sources": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "VULHUB", "id": "VHN-121312" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "NVD", "id": "CVE-2018-11451" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A vulnerability has been identified in Firmware variant IEC 61850 for EN100 Ethernet module (All versions \u003c V4.33), Firmware variant PROFINET IO for EN100 Ethernet module (All versions), Firmware variant Modbus TCP for EN100 Ethernet module (All versions), Firmware variant DNP3 TCP for EN100 Ethernet module (All versions), Firmware variant IEC104 for EN100 Ethernet module (All versions \u003c V1.22), SIPROTEC 5 relays with CPU variants CP300 and CP100 and the respective Ethernet communication modules (All versions \u003c V7.80), SIPROTEC 5 relays with CPU variants CP200 and the respective Ethernet communication modules (All versions \u003c V7.58). Specially crafted packets to port 102/tcp could cause a denial-of-service condition in the affected products. A manual restart is required to recover the EN100 module functionality of the affected devices. Successful exploitation requires an attacker with network access to send multiple packets to the affected products or modules. As a precondition the IEC 61850-MMS communication needs to be activated on the affected products or modules. No user interaction or privileges are required to exploit the vulnerability. The vulnerability could allow causing a Denial-of-Service condition of the network functionality of the device, compromising the availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known. plural Siemens There is an input validation vulnerability in the product firmware.Service operation interruption (DoS) There is a possibility of being put into a state. The Siemens EN100 Ethernet Communication Module and SIPROTEC 5 relays are products of Siemens AG, Germany. The Siemens EN100 Ethernet Communication Module is an Ethernet module. SIPROTEC 5 relays are a relay. A denial of service vulnerability exists in the Siemens EN100 Ethernet Communication Module and SIPROTEC 5 relays. \nAttackers can exploit these issues to crash the affected application or consume excess memory, denying service to legitimate users", "sources": [ { "db": "NVD", "id": "CVE-2018-11451" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "BID", "id": "106221" }, { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "VULHUB", "id": "VHN-121312" } ], "trust": 2.7 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2018-11451", "trust": 3.6 }, { "db": "SIEMENS", "id": "SSA-635129", "trust": 2.6 }, { "db": "BID", "id": "106221", "trust": 2.0 }, { "db": "SIEMENS", "id": "SSA-325546", "trust": 1.7 }, { "db": "ICS CERT", "id": "ICSA-18-347-02", "trust": 1.1 }, { "db": "ICS CERT", "id": "ICSA-19-038-02", "trust": 1.1 }, { "db": "CNNVD", "id": "CNNVD-201807-1730", "trust": 0.9 }, { "db": "CNVD", "id": "CNVD-2018-25425", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2018-008870", "trust": 0.8 }, { "db": "IVD", "id": "7D828321-463F-11E9-BC16-000C29342CB1", "trust": 0.2 }, { "db": "VULHUB", "id": "VHN-121312", "trust": 0.1 } ], "sources": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "VULHUB", "id": "VHN-121312" }, { "db": "BID", "id": "106221" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "NVD", "id": "CVE-2018-11451" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "id": "VAR-201807-1340", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "VULHUB", "id": "VHN-121312" } ], "trust": 1.6473678285714286 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.8 } ], "sources": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25425" } ] }, "last_update_date": "2023-12-18T12:50:37.477000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "SSA-635129", "trust": 0.8, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf" }, { "title": "Patch for Siemens EN100 Ethernet Communication Module and SIPROTEC 5 relays denial of service vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/147343" }, { "title": "Multiple Siemens Product security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=82546" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-20", "trust": 1.9 } ], "sources": [ { "db": "VULHUB", "id": "VHN-121312" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "NVD", "id": "CVE-2018-11451" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 2.9, "url": "https://www.securityfocus.com/bid/106221" }, { "trust": 2.6, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-635129.pdf" }, { "trust": 1.7, "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-325546.pdf" }, { "trust": 1.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-18-347-02" }, { "trust": 1.1, "url": "https://ics-cert.us-cert.gov/advisories/icsa-19-038-02" }, { "trust": 0.8, "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-11451" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2018-11451" }, { "trust": 0.3, "url": "http://www.siemens.com/" } ], "sources": [ { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "VULHUB", "id": "VHN-121312" }, { "db": "BID", "id": "106221" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "NVD", "id": "CVE-2018-11451" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNVD", "id": "CNVD-2018-25425" }, { "db": "VULHUB", "id": "VHN-121312" }, { "db": "BID", "id": "106221" }, { "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "db": "NVD", "id": "CVE-2018-11451" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-14T00:00:00", "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "date": "2018-12-14T00:00:00", "db": "CNVD", "id": "CNVD-2018-25425" }, { "date": "2018-07-23T00:00:00", "db": "VULHUB", "id": "VHN-121312" }, { "date": "2018-07-11T00:00:00", "db": "BID", "id": "106221" }, { "date": "2018-10-31T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "date": "2018-07-23T21:29:00.237000", "db": "NVD", "id": "CVE-2018-11451" }, { "date": "2018-07-23T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2018-12-17T00:00:00", "db": "CNVD", "id": "CNVD-2018-25425" }, { "date": "2019-03-22T00:00:00", "db": "VULHUB", "id": "VHN-121312" }, { "date": "2019-02-11T07:00:00", "db": "BID", "id": "106221" }, { "date": "2019-02-08T00:00:00", "db": "JVNDB", "id": "JVNDB-2018-008870" }, { "date": "2019-03-22T17:29:02.297000", "db": "NVD", "id": "CVE-2018-11451" }, { "date": "2019-04-01T00:00:00", "db": "CNNVD", "id": "CNNVD-201807-1730" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote", "sources": [ { "db": "CNNVD", "id": "CNNVD-201807-1730" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural Siemens Vulnerability related to input validation in product firmware", "sources": [ { "db": "JVNDB", "id": "JVNDB-2018-008870" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Input validation", "sources": [ { "db": "IVD", "id": "7d828321-463f-11e9-bc16-000c29342cb1" }, { "db": "CNNVD", "id": "CNNVD-201807-1730" } ], "trust": 0.8 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.