var-202003-0682
Vulnerability from variot

An exploitable improper host validation vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 Firmware versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). A specially crafted HTTPS POST request can cause the software to connect to an unauthorized host, resulting in unauthorized access to firmware update functionality. An attacker can send an authenticated HTTPS POST request to direct the Cloud Connectivity software to connect to an attacker controlled Azure IoT Hub node. WAGO PFC 200 There is an input verification vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. WAGO PFC 200 is a programmable logic controller (PLC) of the German WAGO company

Show details on source website


{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202003-0682",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "pfc200",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "wago",
        "version": "03.01.07(13)"
      },
      {
        "model": "pfc200",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "wago",
        "version": "03.00.39(12)"
      },
      {
        "model": "pfc200",
        "scope": "eq",
        "trust": 1.4,
        "vendor": "wago",
        "version": "03.02.02(14)"
      },
      {
        "model": "pfc200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "03.02.02\\(14\\)"
      },
      {
        "model": "pfc200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "03.01.07\\(13\\)"
      },
      {
        "model": "pfc200",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "wago",
        "version": "03.00.39\\(12\\)"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "pfc200",
        "version": "03.00.39(12)"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "pfc200",
        "version": "03.01.07(13)"
      },
      {
        "model": null,
        "scope": "eq",
        "trust": 0.4,
        "vendor": "pfc200",
        "version": "03.02.02(14)"
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:03.00.39\\(12\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:03.01.07\\(13\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  },
                  {
                    "cpe23Uri": "cpe:2.3:o:wago:pfc200_firmware:03.02.02\\(14\\):*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": true
                  }
                ],
                "operator": "OR"
              },
              {
                "children": [],
                "cpe_match": [
                  {
                    "cpe23Uri": "cpe:2.3:h:wago:pfc200:-:*:*:*:*:*:*:*",
                    "cpe_name": [],
                    "vulnerable": false
                  }
                ],
                "operator": "OR"
              }
            ],
            "cpe_match": [],
            "operator": "AND"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      }
    ]
  },
  "cve": "CVE-2019-5160",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "NVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "MEDIUM",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Network",
            "authentication": "Single",
            "author": "NVD",
            "availabilityImpact": "Partial",
            "baseScore": 6.5,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-014880",
            "impactScore": null,
            "integrityImpact": "Partial",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Medium",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "CNVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "CNVD-2020-17492",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.6,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "author": "IVD",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.5,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 8.0,
            "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8",
            "impactScore": 6.4,
            "integrityImpact": "PARTIAL",
            "severity": "MEDIUM",
            "trust": 0.2,
            "vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
            "version": "2.9 [IVD]"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "author": "NVD",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 2.3,
            "impactScore": 6.0,
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Network",
            "author": "NVD",
            "availabilityImpact": "High",
            "baseScore": 9.1,
            "baseSeverity": "Critical",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "JVNDB-2019-014880",
            "impactScore": null,
            "integrityImpact": "High",
            "privilegesRequired": "High",
            "scope": "Changed",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2019-5160",
            "trust": 1.0,
            "value": "CRITICAL"
          },
          {
            "author": "NVD",
            "id": "JVNDB-2019-014880",
            "trust": 0.8,
            "value": "Critical"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2020-17492",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202003-311",
            "trust": 0.6,
            "value": "CRITICAL"
          },
          {
            "author": "IVD",
            "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06",
            "trust": 0.2,
            "value": "HIGH"
          },
          {
            "author": "IVD",
            "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8",
            "trust": 0.2,
            "value": "HIGH"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "An exploitable improper host validation vulnerability exists in the Cloud Connectivity functionality of WAGO PFC200 Firmware versions 03.02.02(14), 03.01.07(13), and 03.00.39(12). A specially crafted HTTPS POST request can cause the software to connect to an unauthorized host, resulting in unauthorized access to firmware update functionality. An attacker can send an authenticated HTTPS POST request to direct the Cloud Connectivity software to connect to an attacker controlled Azure IoT Hub node. WAGO PFC 200 There is an input verification vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. WAGO PFC 200 is a programmable logic controller (PLC) of the German WAGO company",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      }
    ],
    "trust": 2.52
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2019-5160",
        "trust": 3.4
      },
      {
        "db": "TALOS",
        "id": "TALOS-2019-0953",
        "trust": 3.0
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492",
        "trust": 1.0
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311",
        "trust": 1.0
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880",
        "trust": 0.8
      },
      {
        "db": "IVD",
        "id": "8131A6F8-7D34-497E-B837-3C3A9ECD1E06",
        "trust": 0.2
      },
      {
        "db": "IVD",
        "id": "51EF958E-045E-4FF7-9809-F60A4D94B2B8",
        "trust": 0.2
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ]
  },
  "id": "VAR-202003-0682",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      }
    ],
    "trust": 1.63251626
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS",
          "Network device"
        ],
        "sub_category": null,
        "trust": 0.6
      },
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.4
      }
    ],
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:58:38.511000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "Top Page",
        "trust": 0.8,
        "url": "https://www.wago.com/us/"
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "NVD-CWE-noinfo",
        "trust": 1.0
      },
      {
        "problemtype": "CWE-20",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 3.0,
        "url": "https://talosintelligence.com/vulnerability_reports/talos-2019-0953"
      },
      {
        "trust": 1.4,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2019-5160"
      },
      {
        "trust": 0.8,
        "url": "https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2019-5160"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-03-09T00:00:00",
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "date": "2020-03-09T00:00:00",
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "date": "2020-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "date": "2020-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "date": "2020-03-11T22:27:41.097000",
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "date": "2020-03-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2020-03-18T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2020-17492"
      },
      {
        "date": "2020-03-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2019-014880"
      },
      {
        "date": "2021-07-21T11:39:23.747000",
        "db": "NVD",
        "id": "CVE-2019-5160"
      },
      {
        "date": "2020-03-17T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "remote",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "WAGO PFC200 Input validation error vulnerability",
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ],
    "trust": 1.0
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "Input validation error",
    "sources": [
      {
        "db": "IVD",
        "id": "8131a6f8-7d34-497e-b837-3c3a9ecd1e06"
      },
      {
        "db": "IVD",
        "id": "51ef958e-045e-4ff7-9809-f60a4d94b2b8"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202003-311"
      }
    ],
    "trust": 1.0
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading...

Loading...

Loading...

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.