A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions < V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication. SIMATIC PCS 7 and SIMATIC WinCC Contains an authentication vulnerability.Information may be obtained. Siemens SIMATIC WinCC is a set of automated data acquisition and monitoring (SCADA) system of Germany's Siemens (Siemens) company.

Siemens SIMATIC WinCC has security vulnerabilities. There are security holes in SIMATIC PCS 7 and SIMATIC WinCC, and there is no related information about this hole at present, please pay attention to CNNVD or manufacturer announcements at any time

Show details on source website

{
  "@context": {
    "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
    "affected_products": {
      "@id": "https://www.variotdbs.pl/ref/affected_products"
    },
    "configurations": {
      "@id": "https://www.variotdbs.pl/ref/configurations"
    },
    "credits": {
      "@id": "https://www.variotdbs.pl/ref/credits"
    },
    "cvss": {
      "@id": "https://www.variotdbs.pl/ref/cvss/"
    },
    "description": {
      "@id": "https://www.variotdbs.pl/ref/description/"
    },
    "exploit_availability": {
      "@id": "https://www.variotdbs.pl/ref/exploit_availability/"
    },
    "external_ids": {
      "@id": "https://www.variotdbs.pl/ref/external_ids/"
    },
    "iot": {
      "@id": "https://www.variotdbs.pl/ref/iot/"
    },
    "iot_taxonomy": {
      "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
    },
    "patch": {
      "@id": "https://www.variotdbs.pl/ref/patch/"
    },
    "problemtype_data": {
      "@id": "https://www.variotdbs.pl/ref/problemtype_data/"
    },
    "references": {
      "@id": "https://www.variotdbs.pl/ref/references/"
    },
    "sources": {
      "@id": "https://www.variotdbs.pl/ref/sources/"
    },
    "sources_release_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_release_date/"
    },
    "sources_update_date": {
      "@id": "https://www.variotdbs.pl/ref/sources_update_date/"
    },
    "threat_type": {
      "@id": "https://www.variotdbs.pl/ref/threat_type/"
    },
    "title": {
      "@id": "https://www.variotdbs.pl/ref/title/"
    },
    "type": {
      "@id": "https://www.variotdbs.pl/ref/type/"
    }
  },
  "@id": "https://www.variotdbs.pl/vuln/VAR-202102-0008",
  "affected_products": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/affected_products#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.5"
      },
      {
        "model": "simatic pcs 7",
        "scope": "eq",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "*"
      },
      {
        "model": "simatic wincc",
        "scope": "lt",
        "trust": 1.0,
        "vendor": "siemens",
        "version": "7.5"
      },
      {
        "model": "simatic pcs 7",
        "scope": null,
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": null
      },
      {
        "model": "simatic wincc",
        "scope": "eq",
        "trust": 0.8,
        "vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
        "version": "7.5 sp2"
      },
      {
        "model": "simatic pcs",
        "scope": "eq",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "7"
      },
      {
        "model": "simatic wincc sp2",
        "scope": "lt",
        "trust": 0.6,
        "vendor": "siemens",
        "version": "v7.5"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      }
    ]
  },
  "configurations": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/configurations#",
      "children": {
        "@container": "@list"
      },
      "cpe_match": {
        "@container": "@list"
      },
      "data": {
        "@container": "@list"
      },
      "nodes": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "CVE_data_version": "4.0",
        "nodes": [
          {
            "children": [],
            "cpe_match": [
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_pcs_7:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:*:*:*:*:*:*:*:*",
                "cpe_name": [],
                "versionEndExcluding": "7.5",
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update1:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              },
              {
                "cpe23Uri": "cpe:2.3:a:siemens:simatic_wincc:7.5:sp1_update2:*:*:*:*:*:*",
                "cpe_name": [],
                "vulnerable": true
              }
            ],
            "operator": "OR"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      }
    ]
  },
  "cve": "CVE-2020-10048",
  "cvss": {
    "@context": {
      "cvssV2": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
      },
      "cvssV3": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
      },
      "severity": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/cvss/severity#"
        },
        "@id": "https://www.variotdbs.pl/ref/cvss/severity"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        },
        "@id": "https://www.variotdbs.pl/ref/sources"
      }
    },
    "data": [
      {
        "cvssV2": [
          {
            "acInsufInfo": false,
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "obtainAllPrivilege": false,
            "obtainOtherPrivilege": false,
            "obtainUserPrivilege": false,
            "severity": "LOW",
            "trust": 1.0,
            "userInteractionRequired": false,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "acInsufInfo": null,
            "accessComplexity": "Low",
            "accessVector": "Local",
            "authentication": "None",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 2.1,
            "confidentialityImpact": "Partial",
            "exploitabilityScore": null,
            "id": "CVE-2020-10048",
            "impactScore": null,
            "integrityImpact": "None",
            "obtainAllPrivilege": null,
            "obtainOtherPrivilege": null,
            "obtainUserPrivilege": null,
            "severity": "Low",
            "trust": 0.8,
            "userInteractionRequired": null,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "CNVD",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "CNVD-2021-12077",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.6,
            "vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          },
          {
            "accessComplexity": "LOW",
            "accessVector": "LOCAL",
            "authentication": "NONE",
            "author": "VULHUB",
            "availabilityImpact": "NONE",
            "baseScore": 2.1,
            "confidentialityImpact": "PARTIAL",
            "exploitabilityScore": 3.9,
            "id": "VHN-162487",
            "impactScore": 2.9,
            "integrityImpact": "NONE",
            "severity": "LOW",
            "trust": 0.1,
            "vectorString": "AV:L/AC:L/AU:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        ],
        "cvssV3": [
          {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "author": "NVD",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "exploitabilityScore": 1.8,
            "impactScore": 3.6,
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "trust": 1.0,
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          {
            "attackComplexity": "Low",
            "attackVector": "Local",
            "author": "NVD",
            "availabilityImpact": "None",
            "baseScore": 5.5,
            "baseSeverity": "Medium",
            "confidentialityImpact": "High",
            "exploitabilityScore": null,
            "id": "CVE-2020-10048",
            "impactScore": null,
            "integrityImpact": "None",
            "privilegesRequired": "Low",
            "scope": "Unchanged",
            "trust": 0.8,
            "userInteraction": "None",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.0"
          }
        ],
        "severity": [
          {
            "author": "NVD",
            "id": "CVE-2020-10048",
            "trust": 1.8,
            "value": "MEDIUM"
          },
          {
            "author": "CNVD",
            "id": "CNVD-2021-12077",
            "trust": 0.6,
            "value": "LOW"
          },
          {
            "author": "CNNVD",
            "id": "CNNVD-202102-796",
            "trust": 0.6,
            "value": "MEDIUM"
          },
          {
            "author": "VULHUB",
            "id": "VHN-162487",
            "trust": 0.1,
            "value": "LOW"
          }
        ]
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "description": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/description#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "A vulnerability has been identified in SIMATIC PCS 7 (All versions), SIMATIC WinCC (All versions \u003c V7.5 SP2). Due to an insecure password verification process, an attacker could bypass the password protection set on protected files, thus being granted access to the protected content, circumventing authentication. SIMATIC PCS 7 and SIMATIC WinCC Contains an authentication vulnerability.Information may be obtained. Siemens SIMATIC WinCC is a set of automated data acquisition and monitoring (SCADA) system of Germany\u0027s Siemens (Siemens) company. \n\r\n\r\nSiemens SIMATIC WinCC has security vulnerabilities. There are security holes in SIMATIC PCS 7 and SIMATIC WinCC, and there is no related information about this hole at present, please pay attention to CNNVD or manufacturer announcements at any time",
    "sources": [
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      }
    ],
    "trust": 2.25
  },
  "external_ids": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/external_ids#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "db": "NVD",
        "id": "CVE-2020-10048",
        "trust": 3.1
      },
      {
        "db": "SIEMENS",
        "id": "SSA-944678",
        "trust": 2.3
      },
      {
        "db": "JVN",
        "id": "JVNVU91083521",
        "trust": 0.8
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933",
        "trust": 0.8
      },
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077",
        "trust": 0.6
      },
      {
        "db": "AUSCERT",
        "id": "ESB-2021.0503",
        "trust": 0.6
      },
      {
        "db": "ICS CERT",
        "id": "ICSA-21-040-09",
        "trust": 0.6
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796",
        "trust": 0.6
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487",
        "trust": 0.1
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "id": "VAR-202102-0008",
  "iot": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": true,
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      }
    ],
    "trust": 1.3468724766666667
  },
  "iot_taxonomy": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "category": [
          "ICS"
        ],
        "sub_category": null,
        "trust": 0.6
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      }
    ]
  },
  "last_update_date": "2023-12-18T11:14:56.789000Z",
  "patch": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/patch#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "title": "SSA-944678",
        "trust": 0.8,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
      },
      {
        "title": "Patch for Siemens SIMATIC WinCC bypass authentication vulnerability",
        "trust": 0.6,
        "url": "https://www.cnvd.org.cn/patchinfo/show/249066"
      },
      {
        "title": "SIMATIC PCS 7  and  SIMATIC WinCC Remediation measures for authorization problem vulnerabilities",
        "trust": 0.6,
        "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=142179"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "problemtype_data": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "problemtype": "CWE-287",
        "trust": 1.1
      },
      {
        "problemtype": "Improper authentication (CWE-287) [NVD Evaluation ]",
        "trust": 0.8
      }
    ],
    "sources": [
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      }
    ]
  },
  "references": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/references#",
      "data": {
        "@container": "@list"
      },
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": [
      {
        "trust": 2.3,
        "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-944678.pdf"
      },
      {
        "trust": 0.8,
        "url": "https://jvn.jp/vu/jvnvu91083521/"
      },
      {
        "trust": 0.8,
        "url": "https://nvd.nist.gov/vuln/detail/cve-2020-10048"
      },
      {
        "trust": 0.6,
        "url": "https://vigilance.fr/vulnerability/simatic-information-disclosure-via-password-protected-pictures-34523"
      },
      {
        "trust": 0.6,
        "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-040-09"
      },
      {
        "trust": 0.6,
        "url": "https://www.auscert.org.au/bulletins/esb-2021.0503"
      }
    ],
    "sources": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "sources": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "sources_release_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-23T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "date": "2021-02-09T00:00:00",
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "date": "2021-10-25T00:00:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "date": "2021-02-09T17:15:13.360000",
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "date": "2021-02-09T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "sources_update_date": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
      "data": {
        "@container": "@list"
      }
    },
    "data": [
      {
        "date": "2021-02-26T00:00:00",
        "db": "CNVD",
        "id": "CNVD-2021-12077"
      },
      {
        "date": "2021-02-11T00:00:00",
        "db": "VULHUB",
        "id": "VHN-162487"
      },
      {
        "date": "2021-10-25T07:34:00",
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      },
      {
        "date": "2021-02-11T03:37:39.923000",
        "db": "NVD",
        "id": "CVE-2020-10048"
      },
      {
        "date": "2021-02-22T00:00:00",
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ]
  },
  "threat_type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/threat_type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "local",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ],
    "trust": 0.6
  },
  "title": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/title#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "SIMATIC\u00a0PCS\u00a07\u00a0 and \u00a0SIMATIC\u00a0WinCC\u00a0 Authentication vulnerabilities in",
    "sources": [
      {
        "db": "JVNDB",
        "id": "JVNDB-2020-015933"
      }
    ],
    "trust": 0.8
  },
  "type": {
    "@context": {
      "@vocab": "https://www.variotdbs.pl/ref/type#",
      "sources": {
        "@container": "@list",
        "@context": {
          "@vocab": "https://www.variotdbs.pl/ref/sources#"
        }
      }
    },
    "data": "authorization issue",
    "sources": [
      {
        "db": "CNNVD",
        "id": "CNNVD-202102-796"
      }
    ],
    "trust": 0.6
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…