var-202109-1974
Vulnerability from variot
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of STU and STA files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202109-1974", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "ecostruxure control expert", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "15.1" }, { "model": "ecostruxure process expert", "scope": "lt", "trust": 1.0, "vendor": "schneider electric", "version": "2021" }, { "model": "remoteconnect", "scope": "eq", "trust": 1.0, "vendor": "schneider electric", "version": null }, { "model": "ecostruxure process expert", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "ecostruxure control expert", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "scadapack remoteconnect for x70", "scope": "eq", "trust": 0.8, "vendor": "schneider electric", "version": "all s" }, { "model": "ecostruxure control expert classic", "scope": null, "trust": 0.7, "vendor": "schneider electric", "version": null } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "NVD", "id": "CVE-2021-22797" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_control_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "15.1", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:ecostruxure_process_expert:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndExcluding": "2021", "vulnerable": true } ], "operator": "OR" }, { "children": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true } ], "operator": "OR" }, { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "OR" } ], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:remoteconnect:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": true }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_470:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_474:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_570:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_574:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false }, { "cpe23Uri": "cpe:2.3:h:schneider-electric:scadapack_575:-:*:*:*:*:*:*:*", "cpe_name": [], "vulnerable": false } ], "operator": "AND" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2021-22797" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "kimiya", "sources": [ { "db": "ZDI", "id": "ZDI-21-1102" } ], "trust": 0.7 }, "cve": "CVE-2021-22797", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "acInsufInfo": false, "accessComplexity": "MEDIUM", "accessVector": "NETWORK", "authentication": "NONE", "author": "NVD", "availabilityImpact": "COMPLETE", "baseScore": 9.3, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 8.6, "id": "CVE-2021-22797", "impactScore": 10.0, "integrityImpact": "COMPLETE", "obtainAllPrivilege": false, "obtainOtherPrivilege": false, "obtainUserPrivilege": false, "severity": "HIGH", "trust": 1.0, "userInteractionRequired": false, "vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-22797", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 1.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "OTHER", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "JVNDB-2021-002515", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2021-22797", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2021-22797", "trust": 1.0, "value": "HIGH" }, { "author": "OTHER", "id": "JVNDB-2021-002515", "trust": 0.8, "value": "High" }, { "author": "ZDI", "id": "CVE-2021-22797", "trust": 0.7, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202109-1469", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "CNNVD", "id": "CNNVD-202109-1469" }, { "db": "NVD", "id": "CVE-2021-22797" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A CWE-22: Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack RemoteConnect for x70 (All versions). User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of STU and STA files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the current user", "sources": [ { "db": "NVD", "id": "CVE-2021-22797" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "VULMON", "id": "CVE-2021-22797" } ], "trust": 2.34 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2021-22797", "trust": 3.2 }, { "db": "SCHNEIDER", "id": "SEVD-2021-257-01", "trust": 1.6 }, { "db": "ZDI", "id": "ZDI-21-1102", "trust": 1.4 }, { "db": "JVN", "id": "JVNVU98742301", "trust": 0.8 }, { "db": "ICS CERT", "id": "ICSA-21-259-02", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2021-002515", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-13461", "trust": 0.7 }, { "db": "CNNVD", "id": "CNNVD-202109-1469", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2021-22797", "trust": 0.1 } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "VULMON", "id": "CVE-2021-22797" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "CNNVD", "id": "CNNVD-202109-1469" }, { "db": "NVD", "id": "CVE-2021-22797" } ] }, "id": "VAR-202109-1974", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.7375 }, "last_update_date": "2022-05-04T08:16:26.089000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "EcoStruxureTM\u00a0Control\u00a0Expert,\u00a0EcoStruxureTM\u00a0Process\u00a0Expert,\u00a0SCADAPack\u00a0RemoteConnect?\u00a0for\u00a0x70", "trust": 0.8, "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2021-257-01" }, { "title": "Schneider Electric has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-259-02" }, { "title": "Schneider Electric EcoStruxure Control Expert Security vulnerabilities", "trust": 0.6, "url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=163280" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "CNNVD", "id": "CNNVD-202109-1469" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-22", "trust": 1.0 }, { "problemtype": "Path traversal (CWE-22) [ Other ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "NVD", "id": "CVE-2021-22797" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.6, "url": "https://www.se.com/ww/en/download/document/sevd-2021-257-01/" }, { "trust": 1.5, "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-259-02" }, { "trust": 0.8, "url": "http://jvn.jp/vu/jvnvu98742301/index.html" }, { "trust": 0.7, "url": "https://www.zerodayinitiative.com/advisories/zdi-21-1102/" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2021-22797/" } ], "sources": [ { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "VULMON", "id": "CVE-2021-22797" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "CNNVD", "id": "CNNVD-202109-1469" }, { "db": "NVD", "id": "CVE-2021-22797" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-21-1102" }, { "db": "VULMON", "id": "CVE-2021-22797" }, { "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "db": "CNNVD", "id": "CNNVD-202109-1469" }, { "db": "NVD", "id": "CVE-2021-22797" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-20T00:00:00", "db": "ZDI", "id": "ZDI-21-1102" }, { "date": "2021-09-22T00:00:00", "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "date": "2021-09-20T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-1469" }, { "date": "2022-04-13T16:15:00", "db": "NVD", "id": "CVE-2021-22797" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2021-09-20T00:00:00", "db": "ZDI", "id": "ZDI-21-1102" }, { "date": "2021-09-22T06:36:00", "db": "JVNDB", "id": "JVNDB-2021-002515" }, { "date": "2022-04-24T00:00:00", "db": "CNNVD", "id": "CNNVD-202109-1469" }, { "date": "2022-04-23T02:12:00", "db": "NVD", "id": "CVE-2021-22797" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-1469" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Schneider\u00a0Electric\u00a0 Made \u00a0EcoStruxure\u00a0 and \u00a0SCADAPack\u00a0 Directory traversal vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2021-002515" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "path traversal", "sources": [ { "db": "CNNVD", "id": "CNNVD-202109-1469" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.