VAR-202204-0324
Vulnerability from variot - Updated: 2023-12-18 11:56A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202204-0324",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "simatic energy manager basic",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic energy manager basic",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic energy manager pro",
"scope": "eq",
"trust": 1.0,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic energy manager pro",
"scope": "lt",
"trust": 1.0,
"vendor": "siemens",
"version": "7.3"
},
{
"model": "simatic energy manager pro",
"scope": "eq",
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": "7.3 update 1"
},
{
"model": "simatic energy manager basic",
"scope": null,
"trust": 0.8,
"vendor": "\u30b7\u30fc\u30e1\u30f3\u30b9",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "NVD",
"id": "CVE-2022-23450"
}
]
},
"configurations": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/configurations#",
"children": {
"@container": "@list"
},
"cpe_match": {
"@container": "@list"
},
"data": {
"@container": "@list"
},
"nodes": {
"@container": "@list"
}
},
"data": [
{
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2022-23450"
}
]
},
"credits": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/credits#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Noam Moshe of Claroty reported these vulnerabilities to Siemens.",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
],
"trust": 0.6
},
"cve": "CVE-2022-23450",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"acInsufInfo": false,
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "NVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"trust": 1.0,
"userInteractionRequired": false,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "None",
"author": "NVD",
"availabilityImpact": "Complete",
"baseScore": 10.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "CVE-2022-23450",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.9,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "NVD",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2022-23450",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "NVD",
"id": "CVE-2022-23450",
"trust": 1.8,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202204-2942",
"trust": 0.6,
"value": "CRITICAL"
},
{
"author": "VULMON",
"id": "CVE-2022-23450",
"trust": 0.1,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-23450"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges",
"sources": [
{
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "VULMON",
"id": "CVE-2022-23450"
}
],
"trust": 1.71
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2022-23450",
"trust": 3.3
},
{
"db": "SIEMENS",
"id": "SSA-655554",
"trust": 1.7
},
{
"db": "ICS CERT",
"id": "ICSA-22-104-11",
"trust": 1.5
},
{
"db": "JVN",
"id": "JVNVU91165555",
"trust": 0.8
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001571",
"trust": 0.8
},
{
"db": "CS-HELP",
"id": "SB2022041913",
"trust": 0.6
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2942",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2022-23450",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-23450"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"id": "VAR-202204-0324",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.50757577
},
"last_update_date": "2023-12-18T11:56:14.875000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "SSA-655554",
"trust": 0.8,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
},
{
"title": "Siemens SIMATIC Fixes for code issue vulnerabilities",
"trust": 0.6,
"url": "http://www.cnnvd.org.cn/web/xxk/bdxqbyid.tag?id=189469"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-502",
"trust": 1.0
},
{
"problemtype": "Deserialization of untrusted data (CWE-502) [NVD Evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "NVD",
"id": "CVE-2022-23450"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
},
{
"trust": 0.9,
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-11"
},
{
"trust": 0.8,
"url": "https://jvn.jp/vu/jvnvu91165555/"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2022-23450"
},
{
"trust": 0.6,
"url": "https://www.cybersecurity-help.cz/vdb/sb2022041913"
},
{
"trust": 0.6,
"url": "https://vigilance.fr/vulnerability/simatic-energy-manager-three-vulnerabilities-38020"
},
{
"trust": 0.6,
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-22-104-11"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2022-23450/"
},
{
"trust": 0.1,
"url": "https://cwe.mitre.org/data/definitions/502.html"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2022-23450"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2022-23450"
},
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-12T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23450"
},
{
"date": "2022-04-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"date": "2022-04-12T09:15:14.357000",
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"date": "2022-04-12T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2022-04-19T00:00:00",
"db": "VULMON",
"id": "CVE-2022-23450"
},
{
"date": "2022-04-22T06:27:00",
"db": "JVNDB",
"id": "JVNDB-2022-001571"
},
{
"date": "2022-04-19T16:07:49.977000",
"db": "NVD",
"id": "CVE-2022-23450"
},
{
"date": "2022-04-20T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "SIMATIC\u00a0Energy\u00a0Manager\u00a0Basic\u00a0 and \u00a0SIMATIC\u00a0Energy\u00a0Manager\u00a0PRO\u00a0 Untrusted Data Deserialization Vulnerability in",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2022-001571"
}
],
"trust": 0.8
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "code problem",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202204-2942"
}
],
"trust": 0.6
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…