var-202301-2075
Vulnerability from variot
Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. Versions prior to and including 4.8 are vulnerable to an out-of-bounds write that can occur in the BLE-L2CAP module. The Bluetooth Low Energy - Logical Link Control and Adaptation Layer Protocol (BLE-L2CAP) module handles fragmentation of packets up the configured MTU size. When fragments are reassembled, they are stored in a packet buffer of a configurable size, but there is no check to verify that the packet buffer is large enough to hold the reassembled packet. In Contiki-NG's default configuration, it is possible that an out-of-bounds write of up to 1152 bytes occurs. The vulnerability has been patched in the "develop" branch of Contiki-NG, and will be included in release 4.9. The problem can be fixed by applying the patch in Contiki-NG pull request #2254 prior to the release of version 4.9. Contiki-NG Exists in an out-of-bounds write vulnerability.Information may be tampered with
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "exploit_availability": { "@id": "https://www.variotdbs.pl/ref/exploit_availability/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202301-2075", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "contiki-ng", "scope": "lte", "trust": 1.0, "vendor": "contiki ng", "version": "4.8" }, { "model": "contiki-ng", "scope": "lte", "trust": 0.8, "vendor": "contiki ng", "version": "4.8 and earlier" }, { "model": "contiki-ng", "scope": "eq", "trust": 0.8, "vendor": "contiki ng", "version": null } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "NVD", "id": "CVE-2023-23609" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:o:contiki-ng:contiki-ng:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "4.8", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-23609" } ] }, "cve": "CVE-2023-23609", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "NVD", "availabilityImpact": "NONE", "baseScore": 7.4, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 4.0, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N", "version": "3.1" }, { "attackComplexity": "LOW", "attackVector": "ADJACENT_NETWORK", "author": "security-advisories@github.com", "availabilityImpact": "LOW", "baseScore": 8.2, "baseSeverity": "HIGH", "confidentialityImpact": "NONE", "exploitabilityScore": 2.8, "impactScore": 4.7, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "CHANGED", "trust": 1.0, "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:L", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Adjacent Network", "author": "NVD", "availabilityImpact": "None", "baseScore": 7.4, "baseSeverity": "High", "confidentialityImpact": "None", "exploitabilityScore": null, "id": "CVE-2023-23609", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Changed", "trust": 0.8, "userInteraction": "None", "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:C/C:N/I:H/A:N", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-23609", "trust": 1.8, "value": "HIGH" }, { "author": "security-advisories@github.com", "id": "CVE-2023-23609", "trust": 1.0, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202301-2003", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "NVD", "id": "CVE-2023-23609" }, { "db": "NVD", "id": "CVE-2023-23609" }, { "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Contiki-NG is an open-source, cross-platform operating system for Next-Generation IoT devices. Versions prior to and including 4.8 are vulnerable to an out-of-bounds write that can occur in the BLE-L2CAP module. The Bluetooth Low Energy - Logical Link Control and Adaptation Layer Protocol (BLE-L2CAP) module handles fragmentation of packets up the configured MTU size. When fragments are reassembled, they are stored in a packet buffer of a configurable size, but there is no check to verify that the packet buffer is large enough to hold the reassembled packet. In Contiki-NG\u0027s default configuration, it is possible that an out-of-bounds write of up to 1152 bytes occurs. The vulnerability has been patched in the \"develop\" branch of Contiki-NG, and will be included in release 4.9. The problem can be fixed by applying the patch in Contiki-NG pull request #2254 prior to the release of version 4.9. Contiki-NG Exists in an out-of-bounds write vulnerability.Information may be tampered with", "sources": [ { "db": "NVD", "id": "CVE-2023-23609" }, { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "CNNVD", "id": "CNNVD-202301-2003" }, { "db": "VULMON", "id": "CVE-2023-23609" } ], "trust": 2.25 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-23609", "trust": 3.3 }, { "db": "JVNDB", "id": "JVNDB-2023-002984", "trust": 0.8 }, { "db": "CNNVD", "id": "CNNVD-202301-2003", "trust": 0.6 }, { "db": "VULMON", "id": "CVE-2023-23609", "trust": 0.1 } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-23609" }, { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "NVD", "id": "CVE-2023-23609" }, { "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "id": "VAR-202301-2075", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "VARIoT devices database", "id": null } ], "trust": 0.48177084 }, "last_update_date": "2023-12-18T13:06:18.587000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Check\u00a0available\u00a0packetbuf\u00a0space\u00a0before\u00a0writing\u00a0to\u00a0it\u00a0in\u00a0ble-l2cap\u00a0#2254 GitHub", "trust": 0.8, "url": "https://github.com/contiki-ng/contiki-ng/pull/2254" }, { "title": "Contiki-NG Buffer error vulnerability fix", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=223365" } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-787", "trust": 1.0 }, { "problemtype": "Out-of-bounds writing (CWE-787) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "NVD", "id": "CVE-2023-23609" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 1.7, "url": "https://github.com/contiki-ng/contiki-ng/security/advisories/ghsa-qr4q-6h3m-h3g7" }, { "trust": 1.7, "url": "https://github.com/contiki-ng/contiki-ng/pull/2254" }, { "trust": 1.4, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-23609" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-23609/" }, { "trust": 0.1, "url": "https://cwe.mitre.org/data/definitions/787.html" }, { "trust": 0.1, "url": "https://nvd.nist.gov" } ], "sources": [ { "db": "VULMON", "id": "CVE-2023-23609" }, { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "NVD", "id": "CVE-2023-23609" }, { "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "VULMON", "id": "CVE-2023-23609" }, { "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "db": "NVD", "id": "CVE-2023-23609" }, { "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-01-26T00:00:00", "db": "VULMON", "id": "CVE-2023-23609" }, { "date": "2023-08-28T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "date": "2023-01-26T21:18:14.100000", "db": "NVD", "id": "CVE-2023-23609" }, { "date": "2023-01-26T00:00:00", "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-01-27T00:00:00", "db": "VULMON", "id": "CVE-2023-23609" }, { "date": "2023-08-28T07:12:00", "db": "JVNDB", "id": "JVNDB-2023-002984" }, { "date": "2023-02-07T19:59:57.987000", "db": "NVD", "id": "CVE-2023-23609" }, { "date": "2023-02-08T00:00:00", "db": "CNNVD", "id": "CNNVD-202301-2003" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "remote or local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202301-2003" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "Contiki-NG\u00a0 Out-of-bounds write vulnerability in", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-002984" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "buffer error", "sources": [ { "db": "CNNVD", "id": "CNNVD-202301-2003" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.