var-202303-1372
Vulnerability from variot
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server There is a vulnerability in deserialization of untrusted data.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the DashFiles class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric)
Show details on source website{ "@context": { "@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#", "affected_products": { "@id": "https://www.variotdbs.pl/ref/affected_products" }, "configurations": { "@id": "https://www.variotdbs.pl/ref/configurations" }, "credits": { "@id": "https://www.variotdbs.pl/ref/credits" }, "cvss": { "@id": "https://www.variotdbs.pl/ref/cvss/" }, "description": { "@id": "https://www.variotdbs.pl/ref/description/" }, "external_ids": { "@id": "https://www.variotdbs.pl/ref/external_ids/" }, "iot": { "@id": "https://www.variotdbs.pl/ref/iot/" }, "iot_taxonomy": { "@id": "https://www.variotdbs.pl/ref/iot_taxonomy/" }, "patch": { "@id": "https://www.variotdbs.pl/ref/patch/" }, "problemtype_data": { "@id": "https://www.variotdbs.pl/ref/problemtype_data/" }, "references": { "@id": "https://www.variotdbs.pl/ref/references/" }, "sources": { "@id": "https://www.variotdbs.pl/ref/sources/" }, "sources_release_date": { "@id": "https://www.variotdbs.pl/ref/sources_release_date/" }, "sources_update_date": { "@id": "https://www.variotdbs.pl/ref/sources_update_date/" }, "threat_type": { "@id": "https://www.variotdbs.pl/ref/threat_type/" }, "title": { "@id": "https://www.variotdbs.pl/ref/title/" }, "type": { "@id": "https://www.variotdbs.pl/ref/type/" } }, "@id": "https://www.variotdbs.pl/vuln/VAR-202303-1372", "affected_products": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/affected_products#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "model": "igss data server", "scope": "lte", "trust": 1.0, "vendor": "schneider electric", "version": "16.0.0.23040" }, { "model": "igss dashboard", "scope": "lte", "trust": 1.0, "vendor": "schneider electric", "version": "16.0.0.23040" }, { "model": "custom reports", "scope": "lte", "trust": 1.0, "vendor": "schneider electric", "version": "16.0.0.23040" }, { "model": "igss dashboard", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "custom reports", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "igss data server", "scope": null, "trust": 0.8, "vendor": "schneider electric", "version": null }, { "model": "igss", "scope": null, "trust": 0.7, "vendor": "schneider electric", "version": null }, { "model": "electric igss data server", "scope": "lte", "trust": 0.6, "vendor": "schneider", "version": "\u003c=v16.0.0.23040" }, { "model": "electric igss dashboard", "scope": "lte", "trust": 0.6, "vendor": "schneider", "version": "\u003c=v16.0.0.23040" }, { "model": "electric custom reports", "scope": "lte", "trust": 0.6, "vendor": "schneider", "version": "\u003c=v16.0.0.23040" } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" }, { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "NVD", "id": "CVE-2023-27978" } ] }, "configurations": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/configurations#", "children": { "@container": "@list" }, "cpe_match": { "@container": "@list" }, "data": { "@container": "@list" }, "nodes": { "@container": "@list" } }, "data": [ { "CVE_data_version": "4.0", "nodes": [ { "children": [], "cpe_match": [ { "cpe23Uri": "cpe:2.3:a:schneider-electric:custom_reports:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.0.0.23040", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:igss_dashboard:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.0.0.23040", "vulnerable": true }, { "cpe23Uri": "cpe:2.3:a:schneider-electric:igss_data_server:*:*:*:*:*:*:*:*", "cpe_name": [], "versionEndIncluding": "16.0.0.23040", "vulnerable": true } ], "operator": "OR" } ] } ], "sources": [ { "db": "NVD", "id": "CVE-2023-27978" } ] }, "credits": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/credits#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "kimiya", "sources": [ { "db": "ZDI", "id": "ZDI-23-334" } ], "trust": 0.7 }, "cve": "CVE-2023-27978", "cvss": { "@context": { "cvssV2": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV2" }, "cvssV3": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#" }, "@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/" }, "severity": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/cvss/severity#" }, "@id": "https://www.variotdbs.pl/ref/cvss/severity" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" }, "@id": "https://www.variotdbs.pl/ref/sources" } }, "data": [ { "cvssV2": [ { "accessComplexity": "LOW", "accessVector": "LOCAL", "authentication": "NONE", "author": "CNVD", "availabilityImpact": "COMPLETE", "baseScore": 7.2, "confidentialityImpact": "COMPLETE", "exploitabilityScore": 3.9, "id": "CNVD-2023-29372", "impactScore": 10.0, "integrityImpact": "COMPLETE", "severity": "HIGH", "trust": 0.6, "vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C", "version": "2.0" } ], "cvssV3": [ { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "NVD", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 2.0, "userInteraction": "REQUIRED", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.1" }, { "attackComplexity": "Low", "attackVector": "Local", "author": "NVD", "availabilityImpact": "High", "baseScore": 7.8, "baseSeverity": "High", "confidentialityImpact": "High", "exploitabilityScore": null, "id": "CVE-2023-27978", "impactScore": null, "integrityImpact": "High", "privilegesRequired": "None", "scope": "Unchanged", "trust": 0.8, "userInteraction": "Required", "vectorString": "CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" }, { "attackComplexity": "LOW", "attackVector": "LOCAL", "author": "ZDI", "availabilityImpact": "HIGH", "baseScore": 7.8, "baseSeverity": "HIGH", "confidentialityImpact": "HIGH", "exploitabilityScore": 1.8, "id": "CVE-2023-27978", "impactScore": 5.9, "integrityImpact": "HIGH", "privilegesRequired": "NONE", "scope": "UNCHANGED", "trust": 0.7, "userInteraction": "REQUIRED", "vectorString": "AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H", "version": "3.0" } ], "severity": [ { "author": "NVD", "id": "CVE-2023-27978", "trust": 1.8, "value": "HIGH" }, { "author": "cybersecurity@se.com", "id": "CVE-2023-27978", "trust": 1.0, "value": "HIGH" }, { "author": "ZDI", "id": "CVE-2023-27978", "trust": 0.7, "value": "HIGH" }, { "author": "CNVD", "id": "CNVD-2023-29372", "trust": 0.6, "value": "HIGH" }, { "author": "CNNVD", "id": "CNNVD-202303-1553", "trust": 0.6, "value": "HIGH" } ] } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" }, { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "NVD", "id": "CVE-2023-27978" }, { "db": "NVD", "id": "CVE-2023-27978" }, { "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "description": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/description#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server There is a vulnerability in deserialization of untrusted data.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the DashFiles class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric)", "sources": [ { "db": "NVD", "id": "CVE-2023-27978" }, { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" } ], "trust": 2.79 }, "external_ids": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/external_ids#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "db": "NVD", "id": "CVE-2023-27978", "trust": 4.5 }, { "db": "SCHNEIDER", "id": "SEVD-2023-073-04", "trust": 3.0 }, { "db": "ICS CERT", "id": "ICSA-23-082-04", "trust": 0.8 }, { "db": "JVN", "id": "JVNVU94559502", "trust": 0.8 }, { "db": "JVNDB", "id": "JVNDB-2023-005626", "trust": 0.8 }, { "db": "ZDI_CAN", "id": "ZDI-CAN-19239", "trust": 0.7 }, { "db": "ZDI", "id": "ZDI-23-334", "trust": 0.7 }, { "db": "CNVD", "id": "CNVD-2023-29372", "trust": 0.6 }, { "db": "AUSCERT", "id": "ESB-2023.1792", "trust": 0.6 }, { "db": "CNNVD", "id": "CNNVD-202303-1553", "trust": 0.6 } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" }, { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "NVD", "id": "CVE-2023-27978" }, { "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "id": "VAR-202303-1372", "iot": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": true, "sources": [ { "db": "CNVD", "id": "CNVD-2023-29372" } ], "trust": 0.06 }, "iot_taxonomy": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "category": [ "ICS" ], "sub_category": null, "trust": 0.6 } ], "sources": [ { "db": "CNVD", "id": "CNVD-2023-29372" } ] }, "last_update_date": "2023-12-18T11:54:51.794000Z", "patch": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/patch#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "title": "Schneider Electric has issued an update to correct this vulnerability.", "trust": 0.7, "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-073-04\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-073-04.pdf" }, { "title": "Patch for Schneider Electric IGSS Data Server Code Issue Vulnerability", "trust": 0.6, "url": "https://www.cnvd.org.cn/patchinfo/show/419141" }, { "title": "Schneider Electric IGSS Data Server Fixes for code issue vulnerabilities", "trust": 0.6, "url": "http://123.124.177.30/web/xxk/bdxqbyid.tag?id=230401" } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" }, { "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "problemtype_data": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/problemtype_data#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "problemtype": "CWE-502", "trust": 1.0 }, { "problemtype": "Deserialization of untrusted data (CWE-502) [ others ]", "trust": 0.8 } ], "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "NVD", "id": "CVE-2023-27978" } ] }, "references": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/references#", "data": { "@container": "@list" }, "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": [ { "trust": 3.7, "url": "https://download.schneider-electric.com/files?p_doc_ref=sevd-2023-073-04\u0026p_endoctype=security+and+safety+notice\u0026p_file_name=sevd-2023-073-04.pdf" }, { "trust": 0.8, "url": "https://jvn.jp/vu/jvnvu94559502/" }, { "trust": 0.8, "url": "https://nvd.nist.gov/vuln/detail/cve-2023-27978" }, { "trust": 0.8, "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-082-04" }, { "trust": 0.6, "url": "https://cxsecurity.com/cveshow/cve-2023-27978/" }, { "trust": 0.6, "url": "https://www.auscert.org.au/bulletins/esb-2023.1792" } ], "sources": [ { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" }, { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "NVD", "id": "CVE-2023-27978" }, { "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "sources": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#", "data": { "@container": "@list" } }, "data": [ { "db": "ZDI", "id": "ZDI-23-334" }, { "db": "CNVD", "id": "CNVD-2023-29372" }, { "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "db": "NVD", "id": "CVE-2023-27978" }, { "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "sources_release_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_release_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-16T00:00:00", "db": "ZDI", "id": "ZDI-23-334" }, { "date": "2023-04-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-29372" }, { "date": "2023-11-09T00:00:00", "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "date": "2023-03-21T09:15:11.470000", "db": "NVD", "id": "CVE-2023-27978" }, { "date": "2023-03-21T00:00:00", "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "sources_update_date": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources_update_date#", "data": { "@container": "@list" } }, "data": [ { "date": "2023-03-16T00:00:00", "db": "ZDI", "id": "ZDI-23-334" }, { "date": "2023-04-20T00:00:00", "db": "CNVD", "id": "CNVD-2023-29372" }, { "date": "2023-11-09T03:11:00", "db": "JVNDB", "id": "JVNDB-2023-005626" }, { "date": "2023-03-24T17:20:49.547000", "db": "NVD", "id": "CVE-2023-27978" }, { "date": "2023-03-27T00:00:00", "db": "CNNVD", "id": "CNNVD-202303-1553" } ] }, "threat_type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/threat_type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "local", "sources": [ { "db": "CNNVD", "id": "CNNVD-202303-1553" } ], "trust": 0.6 }, "title": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/title#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "plural \u00a0Schneider\u00a0Electric\u00a0 Product untrusted data deserialization vulnerability", "sources": [ { "db": "JVNDB", "id": "JVNDB-2023-005626" } ], "trust": 0.8 }, "type": { "@context": { "@vocab": "https://www.variotdbs.pl/ref/type#", "sources": { "@container": "@list", "@context": { "@vocab": "https://www.variotdbs.pl/ref/sources#" } } }, "data": "code problem", "sources": [ { "db": "CNNVD", "id": "CNNVD-202303-1553" } ], "trust": 0.6 } }
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.
- Not patched: This vulnerability was not successfully patched by the user reporting the sighting.